R-4 · Low-density residential district
Yelm, WA · YMC 18.31 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family residential units | Home✓ ADU✓ | — | — | — | — |
| Duplexes | — | Home✓ ADU— | — | — | — |
| Townhouses | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Planned residential development | — | — | — | HomeH ADU— | — |
| Residential care facilities | — | — | — | — | Home✓ ADU— |
| Convalescent care facilities | — | — | — | — | HomeH ADU— |
| Assisted living facilities | — | — | — | — | HomeH ADU— |
| Congregate care facilities | — | — | — | — | HomeH ADU— |
| Emergency housing | — | — | — | — | HomeH ADU— |
| Emergency shelters | — | — | — | — | HomeH ADU— |
| Permanent supportive housing | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | No limit YMC 18.31.040(B) | |
| Maximum density | Not set YMC 18.31.040 | 4 units per acre YMC 18.31.040(A); 18.30.010(C)
for Single-family residential units (1 unit) 1 unit per 14,520 ÷ 2 sq ft YMC 18.31.040(A)
for Duplexes (2 units) |
| Maximum residents | Not read YMC 18.71 | 15 persons YMC 18.02.040
for Residential care facilities (group living) Not set YMC 18.31.040
for Convalescent care facilities (group living); Assisted living facilities (group living); Congregate care facilities (group living) |
| Maximum beds | Not set YMC 18.31.040 | Not read YMC 18.71
for Emergency housing (group living); Emergency shelters (group living); Permanent supportive housing (group living); Transitional housing (group living) |
| Maximum sleeping units | Not set YMC 18.31.040 | Not read YMC 18.71
for Emergency housing (group living); Emergency shelters (group living); Permanent supportive housing (group living); Transitional housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft YMC 18.31.040(D) | |
| Street side setback | 15 ft YMC 18.31.040(E) | 25 ft YMC 18.64.050(A)(3)
for Townhouses (2, 3, 4+ units) |
| Rear setback | 25 ft YMC 18.31.040(F) | |
| Building separation | Not set YMC 18.31.040 | 10 ft YMC 18.64.050(A)(6)
for Townhouses (2, 3, 4+ units); Planned residential development (4+ units) |
| Maximum height | 35 ft YMC 18.31.040(H)(1) | |
| Minimum parking | 2 spaces per unit YMC 18.54.030(A) | (beds in the project ÷ 2) + employees on the largest shift spaces YMC 18.54.030(B)
for Residential care facilities (group living); Convalescent care facilities (group living); Assisted living facilities (group living); Congregate care facilities (group living) For special uses, the parking requirement shall be as provided in that chapter or as determined by the site plan review committee. YMC 18.54.030
for Emergency housing (group living); Emergency shelters (group living); Permanent supportive housing (group living); Transitional housing (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit YMC 18.31.040(J) | |
| Minimum lot size | No limit YMC 18.31.040(B) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft YMC 18.31.040(D) | |
| Rear setback | 25 ft YMC 18.31.040(F) | |
| Maximum height | ||
| Minimum parking | 1 space per unit YMC 18.54.030(A) | |
| Maximum unit size |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision YMC 18.13.030(A)-(B) | A | up to 9 YMC 18.13.030(A) | — | Minimum lot size No limit YMC 18.31.040(B) Maximum lot size Not set YMC 18.31.040 Minimum lot width Not set YMC 18.31.040 Minimum lot depth Not set YMC 18.31.040 Minimum frontage Not set YMC 18.31.040 Maximum units per lot Not set YMC 18.31.040 |
| Administrative subdivision YMC 18.13.040(A)-(B) | A | 10 to 24 YMC 18.13.040(A) | — | Minimum lot size No limit YMC 18.31.040(B) Maximum lot size Not set YMC 18.31.040 Minimum lot width Not set YMC 18.31.040 Minimum lot depth Not set YMC 18.31.040 Minimum frontage Not set YMC 18.31.040 Maximum units per lot Not set YMC 18.31.040 |
| Preliminary subdivision YMC 18.14.050(A)-(B) | H | 25 or more YMC 18.14.050(A) | — | Minimum lot size No limit YMC 18.31.040(B) Maximum lot size Not set YMC 18.31.040 Minimum lot width Not set YMC 18.31.040 Minimum lot depth Not set YMC 18.31.040 Minimum frontage Not set YMC 18.31.040 Maximum units per lot Not set YMC 18.31.040 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The project is a townhouse development or planned residential development that the city approves for the density bonus
- The project is a townhouse development or planned residential development that the city approves for the density bonus
- Class of the street the front yard faces: local access, collector or arterial street is local_access
- Class of the street the front yard faces: local access, collector or arterial street is collector
- Class of the street the front yard faces: local access, collector or arterial street is arterial
- The secondary dwelling unit is in a detached accessory building
- None of these is true:
- The secondary dwelling unit is in a detached accessory building
- Lot area is less than 43,560 sf
- Lot area is at least 43,560 sf