R-48 · Urban Residential-48
Woodinville, WA · WMC 21.20.020; 21.20.030(5) · Official code
By right: 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Townhouse development | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Stacked flat housing development | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Cottage housing development | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Courtyard housing development | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Multiple dwelling unit development | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Multiplex housing development | — | — | — | Home✓ ADU— | — |
| Group residential quarters | — | — | — | — | Home✓ ADU— |
| Residential care facility | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 3 + ((the largest of lot area − 900, 0) ÷ 907, rounded down) units WMC 21.31.030(1); 21.31.030(2)(h); 21.31.050(1) | |
| Minimum units | 3 units WMC 21.31.050(6)(a)(iv) | |
| Minimum lot size | 900 sq ft WMC 21.31.030(1) | |
| Minimum lot width | 25 ft WMC 21.31.030(1) | |
| Minimum frontage | 30 ft WMC 21.31.030(1) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft WMC 21.32.030(2) | |
| Side setback | 5 ft WMC 21.32.030(2) | |
| Street side setback | 10 ft WMC 21.32.030(2) | |
| Rear setback | 5 ft WMC 21.32.030(2) | |
| Maximum height | 45 ft WMC 21.32.040(2) | |
| Maximum lot coverage | ||
| Minimum parking | If a parking requirement for a use is not specified in this chapter, the director shall establish the minimum parking requirement using the most recent version of the Institute of Transportation Engineers Parking Generation Manual, or other professional sources approved by the Director. WMC 21.37.060(3) | for Townhouse development (3, 4+ units); Stacked flat housing development (3, 4+ units); Multiplex housing development (4+ units) |
| Minimum open space | 10% WMC 21.32.050(1) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision WMC 21.91.070(2)(a) | A | up to 9 WMC 21.11A.200 | — | Minimum lot size 900 sq ft WMC 21.31.030(1) Minimum lot width 25 ft WMC 21.31.030(1) Minimum frontage 30 ft WMC 21.31.030(1) |
| Subdivision WMC 21.91.070(2)(c); 21.80.050(3) | H | 10 or more WMC 21.11A.200 | — | Minimum lot size 900 sq ft WMC 21.31.030(1) Minimum lot width 25 ft WMC 21.31.030(1) Minimum frontage 30 ft WMC 21.31.030(1) |
| Unit lot subdivision WMC 21.91.190(3)(b) | A15 | up to 9 WMC 21.11A.220 | — | Maximum lot size The lot area for each unit lot shall not exceed 150 percent of the building footprint inside the boundaries of the unit lot WMC 21.91.190(4)(a) Minimum lot width No limit WMC 21.91.190(4)(c) Minimum frontage No limit WMC 21.91.190(4)(c) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot area is less than 5,000 sf
- All of these are true:
- Lot area is at least 5,000 sf
- Lot area is less than 10,000 sf
- All of these are true:
- Lot area is at least 10,000 sf
- Lot area is less than 15,000 sf
- All of these are true:
- Lot area is at least 15,000 sf
- Lot area is less than 25,000 sf
- All of these are true:
- Lot area is at least 25,000 sf
- Lot area is less than 35,000 sf
- All of these are true:
- Lot area is at least 35,000 sf
- Lot area is less than 43,560 sf
- Lot area is at least 43,560 sf
- Lot area is less than 6,000 sf
- All of these are true:
- Lot area is at least 6,000 sf
- Bedrooms in one unit is at most 2
- All of these are true:
- Lot area is at least 6,000 sf
- Bedrooms in one unit is more than 2
- The multiple dwelling unit development is senior (55+) housing
- All of these are true:
- Lot area is less than 6,000 sf
- The multiple dwelling unit development is senior (55+) housing
- All of these are true:
- Lot area is at least 6,000 sf
- Bedrooms in one unit is at most 2
- The multiple dwelling unit development is senior (55+) housing
- All of these are true:
- Lot area is at least 6,000 sf
- Bedrooms in one unit is more than 2
- The multiple dwelling unit development is senior (55+) housing
- The parent lot contains existing residential dwellings, or new residential dwellings under construction for which valid permits have been issued