Sign in

R-12 · Urban Residential-12

Woodinville, WA · WMC 21.20.020; 21.20.030(4) · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, one-unit
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
——
Duplex, two-unit dwelling—
Home✓ ADU✓
———
Townhouse development——
Home✓ ADU✓
Home✓ ADU✓
—
Stacked flat housing development——
Home✓ ADU✓
Home✓ ADU✓
—
Cottage housing development——
Home✓ ADU✓
Home✓ ADU✓
—
Courtyard housing development——
Home✓ ADU✓
Home✓ ADU✓
—
Multiple dwelling unit development——
Home✓ ADU✓
Home✓ ADU✓
—
Multiplex housing development———
Home✓ ADU✓
—
Manufactured/Mobile Home Park———
Home✓ ADU✓
—
Adult family home————
Home✓ ADU✓
Group residential quarters————
Home✓ ADU—
Residential care facility————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units3 + ((the largest of lot area − 3,600, 0) ÷ 3,630, rounded down) units, ADUs included WMC 21.31.030(1); 21.31.030(2)(e); 21.31.050(1); 21.41.020(2)
Minimum lot size3,600 sq ft WMC 21.31.030(1)
Minimum lot width25 ft WMC 21.31.030(1)
Minimum frontage30 ft WMC 21.31.030(1)
Minimum development sizeNot set WMC 21.31.030
3 × 43,560 sq ft WMC 21.42.050(1)
for Manufactured/Mobile Home Park (4+ units)
Maximum residentsNot set WMC 21.11B
6 persons WMC 21.11B.020
for Adult family home (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft WMC 21.32.030(2)
Side setback5 ft WMC 21.32.030(2)
Street side setback10 ft WMC 21.32.030(2)
Rear setback5 ft WMC 21.32.030(2)
Maximum height35 ft WMC 21.32.040(2)
Maximum lot coverage
  • 65%1 WMC 21.32.050(1)
  • 60%2 WMC 21.32.050(1)
  • 60%3 WMC 21.32.050(1)
  • 60%4 WMC 21.32.050(1)
  • 60%5 WMC 21.32.050(1)
  • 60%6 WMC 21.32.050(1)
  • 50%7 WMC 21.32.050(1)
No limit WMC 21.42.050(5)
for Manufactured/Mobile Home Park (4+ units)
Minimum parkingIf a parking requirement for a use is not specified in this chapter, the director shall establish the minimum parking requirement using the most recent version of the Institute of Transportation Engineers Parking Generation Manual, or other professional sources approved by the Director. WMC 21.37.060(3)
2 spaces per unit WMC 21.37.060(1)
for Dwelling, one-unit (1, 2, 3 units)
  • 1 space per unit8 WMC 21.37.060(1)
  • 1.33 spaces per unit9 WMC 21.37.060(1)
  • 2 spaces per unit10 WMC 21.37.060(1)
for Duplex, two-unit dwelling (2 units); Townhouse development (3, 4+ units); Stacked flat housing development (3, 4+ units); Multiplex housing development (4+ units)
  • 1 space per unit11 WMC 21.37.060(1)
  • 1 space per unit12 WMC 21.37.060(1)
  • 1.33 spaces per unit13 WMC 21.37.060(1)
  • 1.5 spaces per unit14 WMC 21.37.060(1)
for Multiple dwelling unit development (3, 4+ units)
Minimum open space10% WMC 21.32.050(1)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units WMC 21.41.020(1)
Minimum lot size3,600 sq ft WMC 21.41.020(3); 21.31.030(1)

Building

StandardValueExceptions
Front setback10 ft WMC 21.41.020(3); 21.32.030(2)
Side setback5 ft WMC 21.41.020(3); 21.32.030(2)
Rear setback5 ft WMC 21.41.020(3); 21.32.030(2)
Maximum height35 ft WMC 21.41.020(3); 21.32.040(2)
Minimum parking1 space per unit WMC 21.37.060(1)
Maximum unit size1,500 sq ft WMC 21.41.020(3)(b)
Attached to the main houseNot required WMC 21.41.020(3)(a)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision WMC 21.91.070(2)(a) A up to 9 WMC 21.11A.200 —
Minimum lot size
3,600 sq ft WMC 21.31.030(1)
Minimum lot width
25 ft WMC 21.31.030(1)
Minimum frontage
30 ft WMC 21.31.030(1)
Subdivision WMC 21.91.070(2)(c); 21.80.050(3) H 10 or more WMC 21.11A.200 —
Minimum lot size
3,600 sq ft WMC 21.31.030(1)
Minimum lot width
25 ft WMC 21.31.030(1)
Minimum frontage
30 ft WMC 21.31.030(1)
Unit lot subdivision WMC 21.91.190(3)(b)Only for: Dwelling, one-unit, Duplex, two-unit dwelling, Townhouse development, Stacked flat housing development, Cottage housing development, Courtyard housing development, Multiple dwelling unit development, Multiplex housing development, Adult family home, Dwelling unit, accessory A15 up to 9 WMC 21.11A.220 —
Maximum lot size
The lot area for each unit lot shall not exceed 150 percent of the building footprint inside the boundaries of the unit lot WMC 21.91.190(4)(a)
Minimum lot width
No limit WMC 21.91.190(4)(c)
Minimum frontage
No limit WMC 21.91.190(4)(c)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot area is less than 5,000 sf
  2. All of these are true:
    • Lot area is at least 5,000 sf
    • Lot area is less than 10,000 sf
  3. All of these are true:
    • Lot area is at least 10,000 sf
    • Lot area is less than 15,000 sf
  4. All of these are true:
    • Lot area is at least 15,000 sf
    • Lot area is less than 25,000 sf
  5. All of these are true:
    • Lot area is at least 25,000 sf
    • Lot area is less than 35,000 sf
  6. All of these are true:
    • Lot area is at least 35,000 sf
    • Lot area is less than 43,560 sf
  7. Lot area is at least 43,560 sf
  8. Lot area is less than 6,000 sf
  9. All of these are true:
    • Lot area is at least 6,000 sf
    • Bedrooms in one unit is at most 2
  10. All of these are true:
    • Lot area is at least 6,000 sf
    • Bedrooms in one unit is more than 2
  11. The multiple dwelling unit development is senior (55+) housing
  12. All of these are true:
    • Lot area is less than 6,000 sf
    None of these is true:
    • The multiple dwelling unit development is senior (55+) housing
  13. All of these are true:
    • Lot area is at least 6,000 sf
    • Bedrooms in one unit is at most 2
    None of these is true:
    • The multiple dwelling unit development is senior (55+) housing
  14. All of these are true:
    • Lot area is at least 6,000 sf
    • Bedrooms in one unit is more than 2
    None of these is true:
    • The multiple dwelling unit development is senior (55+) housing
  15. The parent lot contains existing residential dwellings, or new residential dwellings under construction for which valid permits have been issued