B1 · Professional Business District (B-1)
Wapato, WA · WMC 17.03.020(B)(1); 17.03.030(E)(1)(a)-(c); 17.03.030(E)(2) · Official code
By right: 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached Single-Family Dwelling | — | — | — | — | |
| Manufactured Homes–New | — | — | — | — | |
| Detached Single-Family Dwelling (Zero Lot Line) | — | — | — | — | |
| Attached Single-Family Dwelling (Common Wall) | — | — | — | — | |
| Two-Family Dwelling (Duplex) | — | — | — | — | |
| Manufactured Home Parks | — | — | |||
| Multifamily Dwelling | — | — | — | ||
| Planned Residential Development | — | — | — | ||
| Adult Family Homes | — | — | — | — | |
| Convalescent or Nursing Home | — | — | — | — | |
| Boarding House | — | — | — | — | |
| Retirement Homes | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum frontage | No limit WMC 17.05.020(H)
| |
| Maximum density | Not set WMC 17.05.030(B) | Not read WMC 17.05.030(B)(2); 17.05.020(A)
12 units per acre, rounded up WMC 17.04.030 Table 4-1; 17.05.030(B)(2)
for Multifamily Dwelling (3, 4+ units) |
| Maximum residents | Not set WMC 17.02.020 | 6 persons WMC 17.02.020
for Adult Family Homes (group living) 10 persons WMC 17.02.020
for Boarding House (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Total side setbacks | Not set WMC 17.05.020 Table 5-1 | |
| Street side setback | STANDARD STRUCTURE SETBACK (5), SIDE: Arterials (2): 40 ft; Collectors (2): 30 ft; Local Access (2): 30 ft; Private Road (2): 30 ft; Minor Local Access (2): 30 ft; Private Access Easement (3) or Property Line: 5 ft. (2) Measured from the centerline of rights-of-way. (3) Measured from the edge of the easement not within a dedicated right-of-way. WMC 17.05.020 Table 5-1; 17.05.020 Table 5-1 note 2; 17.05.020 Table 5-1 note 3 | |
| Rear setback |
|
|
| Maximum height | 50 ft WMC 17.05.020 Table 5-1; 17.05.020(F) | |
| Maximum impervious surface | 80% WMC 17.05.020 Table 5-1; 17.05.020(C) | |
| Minimum parking | for Manufactured Home Parks (2, 3, 4+ units); Planned Residential Development (3, 4+ units)8; Boarding House (group living) for Adult Family Homes (group living); Convalescent or Nursing Home (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit WMC 17.04.110 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Rear setback |
|
|
| Maximum height | 50 ft WMC 17.05.020 Table 5-1; 17.05.020(F); 17.04.110(B) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision WMC 16.15.060; 16.15.080 | H | up to 4 WMC 16.10.270; 16.15.020 | Not read WMC 17.05.030(B)(2); 17.05.020(A) | Minimum lot size Not read WMC 17.05.030(C); 17.05.020(A) Minimum lot width Not read WMC 17.05.030(D); 17.05.020(A) Minimum lot depth Not read WMC 17.05.030(A); 17.05.020(A) Minimum frontage 20 ft WMC 16.25.040(B) Maximum units per lot Not set WMC 17.05.030; 16.25.030 |
| Subdivision WMC 16.20.030(A); 16.20.090 | H | 5 or more WMC 16.10.290; 16.20.020 | Not read WMC 17.05.030(B)(2); 17.05.020(A) | Minimum lot size Not read WMC 17.05.030(C); 17.05.020(A) Minimum lot width Not read WMC 17.05.030(D); 17.05.020(A) Minimum lot depth Not read WMC 17.05.030(A); 17.05.020(A) Minimum frontage 20 ft WMC 16.25.040(B) Maximum units per lot Not set WMC 17.05.030; 16.25.030 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- A physician certifies the unit is for a person who needs daily care or supervision
- The manufactured home is a new manufactured home (never titled to a retail purchaser)
- All of these are true:
- The manufactured home is a new manufactured home (never titled to a retail purchaser)
- A physician certifies the unit is for a person who needs daily care or supervision
- The lot is in a subdivision or short subdivision approved after the effective date of the zoning title
- None of these is true:
- The lot is in a subdivision or short subdivision approved after the effective date of the zoning title
- All of these are true:
- The lot is in a subdivision or short subdivision approved after the effective date of the zoning title
- A physician certifies the unit is for a person who needs daily care or supervision
- All of these are true:
- A physician certifies the unit is for a person who needs daily care or supervision
- The lot is in a subdivision or short subdivision approved after the effective date of the zoning title
- The project combines multifamily residential and commercial use(s) into a single coordinated project
- All of these are true:
- The project combines multifamily residential and commercial use(s) into a single coordinated project
- A physician certifies the unit is for a person who needs daily care or supervision
- None of these is true:
- The lot is served by an access easement at least twenty feet wide
- The lot is served by an access easement at least twenty feet wide
- (main dwelling units on the lot × 43,560) ÷ lot area is more than 12
- Kind of street or access the lot fronts on (Table 5-1 front setback rows) is arterial
- Kind of street or access the lot fronts on (Table 5-1 front setback rows) is collector
- Kind of street or access the lot fronts on (Table 5-1 front setback rows) is local_access
- Kind of street or access the lot fronts on (Table 5-1 front setback rows) is private_road
- Kind of street or access the lot fronts on (Table 5-1 front setback rows) is minor_local_access
- Kind of street or access the lot fronts on (Table 5-1 front setback rows) is private_access_easement
- Zoning of the land across the interior side lot line: the same district, another residential district (SR, R-1, R-2, R-3), or a commercial or industrial district is one of same_district, commercial_industrial_district
- Zoning of the land across the interior side lot line: the same district, another residential district (SR, R-1, R-2, R-3), or a commercial or industrial district is residential_district
- What is across the rear lot line: land in the same district, another residential district, a commercial or industrial district, or a street is street
- What is across the rear lot line: land in the same district, another residential district, a commercial or industrial district, or a street is one of same_district, commercial_industrial_district
- What is across the rear lot line: land in the same district, another residential district, a commercial or industrial district, or a street is residential_district
- The lot is in the downtown business district shaded on Figure 6-1, exempt from the number of required parking spaces
- None of these is true:
- The lot is in the downtown business district shaded on Figure 6-1, exempt from the number of required parking spaces
- All of these are true:
- Main dwelling units on the lot is 4
- The lot is in the downtown business district shaded on Figure 6-1, exempt from the number of required parking spaces
- All of these are true:
- Main dwelling units on the lot is 5
- The lot is in the downtown business district shaded on Figure 6-1, exempt from the number of required parking spaces
- All of these are true:
- Main dwelling units on the lot is at least 6
- The lot is in the downtown business district shaded on Figure 6-1, exempt from the number of required parking spaces