LSN · Low-Scale Neighborhood District (LS)
Vancouver, WA · VMC 20.410.050 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Family Residential Building Type (SFB) | Home✓ ADU✓ | — | — | — | — |
| Townhouse/Rowhouse Building Type (TRB) | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Stacked Multi-Plex Building Type (SMB) | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Flex-Plex Building Type (FPB) | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Cottage Court Building Type (CCB) | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Mixed-Use Residential Building Type (MXB) | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Residential Care Home | — | — | — | — | Home✓ ADU— |
| Temporary shelter/housing (i.e., safe stays, transitional housing) | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set VMC 20.420.080(A) | 6 units VMC 20.420.100(A)
for Flex-Plex Building Type (FPB) (4+ units) |
| Minimum lot size | No limit VMC 20.420.070(C)(1)(a)(i) | Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Minimum density | for Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units) Not set VMC 20.180.030
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 | |
| Maximum density | No limit VMC 20.410.050(C)(2) | |
| Maximum residents | 8 persons VMC 20.430.050(A)(2)(a)(ii); 20.150.040E | Not set VMC 20.430.050(A)(1)
for Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 5 ft VMC 20.420.070(D)(1)(f)(i) | Not set VMC 20.420.140(D)(1)(f)
for Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units); Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Maximum front setback | 20 ft VMC 20.420.070(D)(1)(f)(i) | 25 ft VMC 20.420.110(D)(1)(f)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units) 5 ft VMC 20.420.140(D)(1)(f)(i)
for Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units) Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Side setback | 5 ft VMC 20.420.070(D)(1)(h)(i) | Subject to screening and buffering standards. VMC 20.420.140(D)(1)(h)(i)
for Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units) Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Street side setback | 5 ft VMC 20.420.070(D)(1)(g)(i) | Not set VMC 20.420.140(D)(1)(g)
for Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units); Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Rear setback | 5 ft VMC 20.420.070(D)(1)(i)(i)
for Single-Family Residential Building Type (SFB) (1 unit) Subject to screening and buffering standards. VMC 20.420.140(D)(1)(i)(i)
for Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units) Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 | |
| Maximum height | ||
| Maximum stories | ||
| Minimum height | No limit VMC 20.410.050(D)(1) | |
| Maximum impervious surface | 85% VMC 20.420.080(C)(1)(e)(i) | 65% VMC 20.420.070(C)(1)(e)(i)
for Single-Family Residential Building Type (SFB) (1 unit); Flex-Plex Building Type (FPB) (2, 3 units) No limit VMC 20.420.110(C)(1)(e)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units); Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units) for Flex-Plex Building Type (FPB) (4+ units) Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Minimum parking | 0 spaces per unit VMC 20.450.045(F)(5); VMC 20.420.070(F)(1)(r)(i) | 0 spaces per resident VMC 20.450.045(F)(5)
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Maximum unit size | Not set VMC 20.420.070 | 1,600 sq ft VMC 20.450.080(A)(1)
for Cottage Court Building Type (CCB) (2, 3, 4+ units) |
| Maximum lot size | No limit VMC 20.420.090(C)(1)(a)(ii) | 5,000 sq ft VMC 20.420.070(C)(1)(a)(ii)
for Single-Family Residential Building Type (SFB) (1 unit); Townhouse/Rowhouse Building Type (TRB) (2, 3, 4+ units) 40,000 sq ft VMC 20.420.100(C)(1)(a)(ii)
for Flex-Plex Building Type (FPB) (2, 3, 4+ units); Cottage Court Building Type (CCB) (2, 3, 4+ units) Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Minimum open space | 10% VMC 20.420.080(C)(1)(d)(i) | 20% VMC 20.420.070(C)(1)(d)(i)
for Single-Family Residential Building Type (SFB) (1 unit) No limit VMC 20.420.110(C)(1)(d)(i)
for Cottage Court Building Type (CCB) (2, 3, 4+ units); Mixed-Use Residential Building Type (MXB) (2, 3, 4+ units) Not set VMC 20.410.050
for Residential Care Home (group living); Temporary shelter/housing (i.e., safe stays, transitional housing) (group living)1 |
| Maximum units per building | Not set VMC 20.420.080(A) | 1 unit VMC 20.420.070(A)
for Single-Family Residential Building Type (SFB) (1 unit) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not read RCW 36.70A.681; named in VMC 20.420.080(A) | 2 units VMC 20.420.100(A)
for Single-Family Residential Building Type (SFB) (1 unit); Flex-Plex Building Type (FPB) (2, 3, 4+ units) |
| Minimum lot size | No limit VMC 20.420.100(C)(1)(a)(i) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 5 ft VMC 20.420.100(D)(1)(f)(i) | |
| Side setback | 5 ft VMC 20.420.100(D)(1)(h)(i) | |
| Rear setback | ||
| Maximum height | ||
| Maximum stories | ||
| Minimum parking | 0 spaces per unit VMC 20.450.045(F)(5) | |
| Maximum unit size | 1,000 sq ft VMC 20.150.040A | |
| Attached to the main house | Not required VMC 20.150.040A | Required VMC 20.450.080(A)(6)(c)
for Cottage Court Building Type (CCB) (2, 3, 4+ units) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision VMC 20.320.020(A)(1) | A | up to 9 VMC 20.320.015(A) | — | Minimum frontage 16 ft VMC 20.320.070(A)(1)(g) |
| Subdivision VMC 20.320.020(A)(1) | H | 10 or more VMC 20.320.015(B) | — | Minimum frontage 16 ft VMC 20.320.070(A)(1)(g) |
| Unit Lot Subdivision VMC 20.320.100(C); 20.320.020(A)(1) | A12 | up to 9 VMC 20.320.100(B)(2) | — | Minimum lot size Each unit lot’s area and width for purposes of subdivision may be as small as the footprint of the building situated upon it, subject to the requirements of the building and fire codes. VMC 20.320.100(D)(6) |
| Administrative Lot Split VMC 20.320.110(E) | A13 | up to 2 VMC 20.320.110(C) | Minimum density 8 units per acre VMC 20.320.110(F)(3); 20.410.050(C)(1) |
Maximum lot size No limit VMC 20.320.110(F)(4) Minimum frontage No limit VMC 20.320.110(F)(4) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Property is owned or controlled by a religious organization
- All of these are true:
- Lot was developed or approved before June 30, 2026
- Main dwelling units on the lot is at most 6
- Not all of these are true:
- Lot was developed or approved before June 30, 2026
- Main dwelling units on the lot is at most 6
- Any of these is true:
- All of these are true:
- Lot was developed or approved before June 30, 2026
- Main dwelling units on the lot is at most 6
- 25 percent or more of the gross ground-floor area is active retail, office or passive retail uses
- All of these are true:
- None of these is true:
- All of these are true:
- Lot was developed or approved before June 30, 2026
- Main dwelling units on the lot is at most 6
- 25 percent or more of the gross ground-floor area is active retail, office or passive retail uses
- All of these are true:
- None of these is true:
- The rear lot line abuts an alley
- The rear lot line abuts an alley
- None of these is true:
- Lot is within the Station Areas Overlay (Figure 20.530.020-1), within one-quarter mile of an existing or planned bus rapid or light rail transit
- Lot is within the Station Areas Overlay (Figure 20.530.020-1), within one-quarter mile of an existing or planned bus rapid or light rail transit
- Main dwelling units on the lot is at most 6
- Main dwelling units on the lot is more than 6
- The division is for residential development only, with no commercial or other nonresidential use
- All of these are true:
- The lot is an existing residential lot
- The lot was created through an administrative lot split