R1 · Residential 1
University Place, WA · UPMC 19.20.030(B)(1); 19.25.110; 19.45.100 · Official code
By right: 1 unit, 2 units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family | — | — | — | — | |
| New manufactured home | — | — | — | — | |
| Small lot housing | HomeA ADU— | — | — | HomeA ADU— | — |
| Middle housing | — | — | |||
| Single-family attached housing | — | Home✓ ADU— | — | ||
| Adult family home (6 or fewer) | — | — | — | — | Home✓ ADU— |
| Level I group home | — | — | — | — | Home✓ ADU— |
| Rooming house | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 4 units, ADUs included UPMC 19.45.035(B); 19.45.035(D); 19.45.100 | Not set UPMC 19.45.100
for Small lot housing (4+ units) |
| Minimum lot size |
|
No limit UPMC 19.45.090(B)
for Small lot housing (1, 4+ units) |
| Minimum lot width | 60 ft UPMC 19.45.100; 19.45.110(15) | Minimum lot widths for small lot developments shall be determined through the design standard review process. UPMC 19.45.110(15)
for Small lot housing (1, 4+ units) |
| Maximum density | Not set UPMC 19.45.100 | 6 units per acre, on the net lot area UPMC 19.45.100; 19.45.030(D); 19.45.110(3)
for Small lot housing (1, 4+ units) |
| Maximum residents | Not set UPMC 19.25.040 | 6 persons UPMC 19.25.040(A)
for Adult family home (6 or fewer) (group living) |
| Maximum sleeping units | Not set UPMC 19.25.040 | 4 sleeping units UPMC 19.25.040(M)
for Rooming house (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft UPMC 19.45.100 | 10 ft UPMC 19.45.110(19); 19.53.180 SL3.2.1(a)
for Small lot housing (1, 4+ units) |
| Side setback | 8 ft UPMC 19.45.100 | 5 ft UPMC 19.45.110(19); 19.53.180 SL3.2.1(c)
for Small lot housing (1, 4+ units) |
| Street side setback | 10 ft UPMC 19.45.110(19); 19.53.180 SL3.2.1(d)
for Small lot housing (1, 4+ units) | |
| Rear setback | 30 ft UPMC 19.45.100 | 10 ft UPMC 19.45.110(19); 19.53.180 SL3.2.1(e)
for Small lot housing (1, 4+ units) |
| Maximum height | 35 ft UPMC 19.45.100 | |
| Maximum lot coverage | 50% UPMC 19.45.100; 19.45.110(17) | |
| Maximum impervious surface | Not set UPMC 19.45.100 | 50% UPMC 19.45.110(17)
for Small lot housing (1, 4+ units) |
| Maximum floor area ratio | 0.47 UPMC 19.45.100; 19.45.110(21)
for Small lot housing (1, 4+ units) | |
| Minimum parking | 2 spaces per unit UPMC 19.60.050 | (2 × main dwelling units on the lot) + 1 spaces UPMC 19.60.050
for Small lot housing (1, 4+ units) employees on the largest shift + 2 spaces UPMC 19.60.050
for Adult family home (6 or fewer) (group living) 0.5 spaces per bed UPMC 19.60.050
for Level I group home (group living) In the case of a use not specifically mentioned in this chapter, the requirements for off-street parking facilities shall be determined by the Director. UPMC 19.60.070
for Rooming house (group living); Transitional housing (group living); Permanent supportive housing (group living) |
| Maximum unit size | Not set UPMC 19.45.100 | 2,000 sq ft UPMC 19.53.190 SL9.1.7
for Small lot housing (1, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit UPMC 19.70.010(B)(1); 19.45.035(B); 19.45.035(C)(1)(b) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft UPMC 19.45.100; 19.70.010(B)(4) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft UPMC 19.70.010(B)(3) | |
| Attached to the main house | Not required UPMC 19.70.010(B)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision UPMC 21.35.060(A) | A | up to 9 UPMC 21.10.010 | — | Minimum lot size 9,000 sq ft UPMC 19.45.100; 19.45.090(A) Minimum lot width 60 ft UPMC 19.45.100; 19.45.110(15) |
| Subdivision UPMC 21.20.050(A) | H | 10 or more UPMC 21.10.010 | — | Minimum lot size 9,000 sq ft UPMC 19.45.100; 19.45.090(A) Minimum lot width 60 ft UPMC 19.45.100; 19.45.110(15) |
| Unit lot subdivision UPMC 21.75.020 | A | up to 9 UPMC 21.75.020 | Minimum units 2 units UPMC 21.75.010(B) |
Minimum lot size Not set UPMC 21.75.030 |
| Unit lot subdivision UPMC 21.75.020; 21.20.050(A) | H | 10 or more UPMC 21.75.020 | Minimum units 2 units UPMC 21.75.010(B) |
Minimum lot size Not set UPMC 21.75.030 |
| Residential condominium binding site plan UPMC 21.45.040; 21.40.050(A) | A | Maximum lots Not set UPMC 21.45 |
— | Minimum lot size Not set UPMC 21.45 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot area is at least 9,000 sf
- Lot area is less than 9,000 sf
- Any of these is true:
- The lot is within one-quarter mile of a major transit stop
- At least one unit on the lot meets the affordable housing requirements of 19.45.035(D)(2)(a)-(d)
- None of these is true:
- The lot was legally created before the ordinance and cannot meet the zone's density and minimum lot dimensions
- The lot was legally created before the ordinance and cannot meet the zone's density and minimum lot dimensions
- The side yard is the common lot line of attached units
- None of these is true:
- The side yard is the common lot line of attached units
- None of these is true:
- The second front yard of the corner lot abuts an arterial street
- The second front yard of the corner lot abuts an arterial street
- A minimum roof slope of 6:12 is provided for all parts of the roof above 20 feet
- None of these is true:
- A minimum roof slope of 6:12 is provided for all parts of the roof above 20 feet
- Lot area is at most 6,000 sf
- Lot area is more than 6,000 sf
- The ADU is the one detached ADU placed within the required side or rear yard under UPMC 19.45.040(H)
- None of these is true:
- The ADU is the one detached ADU placed within the required side or rear yard under UPMC 19.45.040(H)
- Property is within one-half mile walking distance of a major transit stop (RCW 36.70A.696)
- All of these are true:
- Lot area is at most 6,000 sf
- Property is within one-half mile walking distance of a major transit stop (RCW 36.70A.696)
- All of these are true:
- Lot area is more than 6,000 sf
- Property is within one-half mile walking distance of a major transit stop (RCW 36.70A.696)