MU-N45 · Mixed Use – Neighborhood
University Place, WA · UPMC 19.20.030(B)(8); 19.54 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Live-work unit | Home✓ ADU— | — | — | — | — |
| Single-family | — | — | — | — | |
| New manufactured home | — | — | — | — | |
| Single-family attached housing | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Multifamily housing | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Adult family home (6 or fewer) | — | — | — | — | Home✓ ADU— |
| Assisted living facility | — | — | — | — | Home✓ ADU— |
| Nursing home | — | — | — | — | Home✓ ADU— |
| Emergency housing | — | — | — | — | Home✓ ADU— |
| Emergency shelter | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,000 sq ft UPMC 19.45.100 |
for Single-family (1 unit)1 |
| Minimum lot width | Not set UPMC 19.45.100 | 60 ft UPMC 19.45.100; 19.45.110(15)
for Single-family (1 unit)1 |
| Maximum density | No limit UPMC 19.45.100 | Not set UPMC 19.45.100
for Single-family (1 unit)1 |
| Maximum residents | Not set UPMC 19.25.040 | 6 persons UPMC 19.25.040(A)
for Adult family home (6 or fewer) (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft UPMC 19.54.060(A) | 0 ft UPMC 19.54.060(C)
for Live-work unit (1 unit) 20 ft UPMC 19.45.100
for Single-family (1 unit)1 5 ft UPMC 19.54.060(B)
for New manufactured home (1 unit); Single-family attached housing (2, 3, 4+ units) |
| Maximum front setback | 20 ft UPMC 19.54.060(C) | Not set UPMC 19.45.100
for Single-family (1 unit)1 |
| Side setback | 0 ft UPMC 19.54.060(E) | 5 ft UPMC 19.54.060(C)
for Live-work unit (1 unit); New manufactured home (1 unit); Single-family attached housing (2, 3, 4+ units); Multifamily housing (3 units) 8 ft UPMC 19.45.100
for Single-family (1 unit)1 |
| Street side setback | Not set UPMC 19.45.100 | |
| Rear setback | 30 ft UPMC 19.45.100
for Single-family (1 unit)1 for New manufactured home (1 unit); Single-family attached housing (2, 3, 4+ units) 10 ft UPMC 19.54.060(A)
for Multifamily housing (3 units) | |
| Maximum height | 45 ft UPMC 19.45.100; 19.54.060(A) | 35 ft UPMC 19.45.100
for Single-family (1 unit)1 |
| Minimum height | 25 ft UPMC 19.50.050(A)(3) | Not set UPMC 19.45.100
for Single-family (1 unit)1 |
| Maximum lot coverage | Not set UPMC 19.45.100 | 50% UPMC 19.45.100; 19.45.110(17)
for Single-family (1 unit)1 |
| Maximum floor area ratio | Not set UPMC 19.45.080 | |
| Minimum parking | In the case of a use not specifically mentioned in this chapter, the requirements for off-street parking facilities shall be determined by the Director. UPMC 19.60.070 | 2 spaces per unit UPMC 19.60.050
for Single-family (1 unit)1; New manufactured home (1 unit); Single-family attached housing (2, 3, 4+ units) for Multifamily housing (3, 4+ units) employees on the largest shift + 2 spaces UPMC 19.60.050
for Adult family home (6 or fewer) (group living) 0.5 spaces per bed UPMC 19.60.050
for Assisted living facility (group living) 0.25 spaces per bed UPMC 19.60.050
for Nursing home (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units UPMC 19.70.010(B)(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 5 ft UPMC 19.54.060(B); 19.70.010(B)(4) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft UPMC 19.70.010(B)(3) | |
| Attached to the main house | Not required UPMC 19.70.010(B)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision UPMC 21.35.060(A) | A | up to 9 UPMC 21.10.010 | — | Minimum lot size 4,000 sq ft UPMC 19.45.100 |
| Subdivision UPMC 21.20.050(A) | H | 10 or more UPMC 21.10.010 | — | Minimum lot size 4,000 sq ft UPMC 19.45.100 |
| Unit lot subdivision UPMC 21.75.020 | A | up to 9 UPMC 21.75.020 | Minimum units 2 units UPMC 21.75.010(B) |
Minimum lot size Not set UPMC 21.75.030 |
| Unit lot subdivision UPMC 21.75.020; 21.20.050(A) | H | 10 or more UPMC 21.75.020 | Minimum units 2 units UPMC 21.75.010(B) |
Minimum lot size Not set UPMC 21.75.030 |
| Residential condominium binding site plan UPMC 21.45.040; 21.40.050(A) | A | Maximum lots Not set UPMC 21.45 |
— | Minimum lot size Not set UPMC 21.45 |
| Binding site plan UPMC 21.40.050(A) | A | Maximum lots Not set UPMC 21.40 |
— | Minimum lot size 4,000 sq ft UPMC 19.45.100 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The single-family detached dwelling already exists (existing single-family detached housing)
- All of these are true:
- The single-family detached dwelling already exists (existing single-family detached housing)
- Lot area is at least 4,000 sf
- All of these are true:
- The single-family detached dwelling already exists (existing single-family detached housing)
- Lot area is less than 4,000 sf
- Lot area is at least 4,000 sf
- Lot area is less than 4,000 sf
- None of these is true:
- The lot was legally created before the ordinance and cannot meet the zone's density and minimum lot dimensions
- The lot was legally created before the ordinance and cannot meet the zone's density and minimum lot dimensions
- None of these is true:
- The second front yard of the corner lot abuts an arterial street
- The second front yard of the corner lot abuts an arterial street
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- None of these is true:
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- All of these are true:
- Bedrooms in one unit is less than 2
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- All of these are true:
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is at most 2
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- All of these are true:
- Bedrooms in one unit is at least 3
- Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
- The ADU is the one detached ADU placed within the required side or rear yard under UPMC 19.45.040(H)
- None of these is true:
- The ADU is the one detached ADU placed within the required side or rear yard under UPMC 19.45.040(H)
- All of these are true:
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- The ADU is the one detached ADU placed within the required side or rear yard under UPMC 19.45.040(H)
- None of these is true:
- The ADU is the one detached ADU placed within the required side or rear yard under UPMC 19.45.040(H)
- The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
- Property is within one-half mile walking distance of a major transit stop (RCW 36.70A.696)
- All of these are true:
- Lot area is at most 6,000 sf
- Property is within one-half mile walking distance of a major transit stop (RCW 36.70A.696)
- All of these are true:
- Lot area is more than 6,000 sf
- Property is within one-half mile walking distance of a major transit stop (RCW 36.70A.696)