Sign in

MU-M · Mixed Use – Maritime

University Place, WA · UPMC 19.20.030(B)(13); 19.25.110; 19.45.100 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live-work unit
HomeA1 H2 ADU—
————
Multifamily housing——
HomeA1 H2 ADU—
HomeA1 H2 ADU—
—
Adult family home (6 or fewer)————
Home✓ ADU—
Level I group home————
Home✓ ADU—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—
Emergency housing————
Home✓ ADU—
Emergency shelter————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum density
  • 30 units per acre, on the net lot area3 UPMC 19.45.100; 19.45.030(A); 19.45.030(C)
  • 35 units per acre, on the net lot area4 UPMC 19.45.100; 19.45.110(3)
Maximum residentsNot set UPMC 19.25.040
6 persons UPMC 19.25.040(A)
for Adult family home (6 or fewer) (group living)

3. Building standards

StandardValueExceptions
Front setback0 ft UPMC 19.45.100
Side setback
  • 0 ft5 UPMC 19.45.110(4)
  • 20 ft6 UPMC 19.45.110(4)
  • 10 ft7 UPMC 19.45.110(4)
  • 30 ft8 UPMC 19.45.110(4)
Rear setback
  • 0 ft5 UPMC 19.45.110(4)
  • 20 ft6 UPMC 19.45.110(4)
  • 10 ft7 UPMC 19.45.110(4)
  • 30 ft8 UPMC 19.45.110(4)
Maximum height
  • 35 ft9 UPMC 19.45.110(24)
  • Height may be increased for buildings or structures located more than 100 feet from the OHWM or when located on the upland (easterly) side of 91st Avenue West, up to a range of 45 to 65 feet, when a visual impact assessment is submitted in accordance with UPMC § 18.25.110(E) and the decision-maker determines that a proposal will comply with the purpose and intent of UPMC § 18.25.110 regarding view protection.10 UPMC 19.45.110(24)
Minimum height25 ft UPMC 19.50.050(A)(3)
Maximum impervious surface
  • 50%11 UPMC 19.45.110(22)
  • 65%12 UPMC 19.45.110(22)
  • 75%13 UPMC 19.45.110(23)
  • 90%14 UPMC 19.45.110(23)
Minimum parkingIn the case of a use not specifically mentioned in this chapter, the requirements for off-street parking facilities shall be determined by the Director. UPMC 19.60.070
  • 0.75 spaces per unit15 UPMC 19.60.050
  • 1 space per unit16 UPMC 19.60.050
  • 1.25 spaces per unit17 UPMC 19.60.050
  • 1.5 spaces per unit18 UPMC 19.60.050
for Multifamily housing (3, 4+ units)1; Multifamily housing (3, 4+ units)2
employees on the largest shift + 2 spaces UPMC 19.60.050
for Adult family home (6 or fewer) (group living)
0.5 spaces per bed UPMC 19.60.050
for Level I group home (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision UPMC 21.35.060(A) A up to 9 UPMC 21.10.010 —
Minimum lot size
Not set UPMC 19.45.100
Subdivision UPMC 21.20.050(A) H 10 or more UPMC 21.10.010 —
Minimum lot size
Not set UPMC 19.45.100
Unit lot subdivision UPMC 21.75.020 A up to 9 UPMC 21.75.020
Minimum units
2 units UPMC 21.75.010(B)
Minimum lot size
Not set UPMC 21.75.030
Unit lot subdivision UPMC 21.75.020; 21.20.050(A) H 10 or more UPMC 21.75.020
Minimum units
2 units UPMC 21.75.010(B)
Minimum lot size
Not set UPMC 21.75.030
Residential condominium binding site plan UPMC 21.45.040; 21.40.050(A) A
Maximum lots
Not set UPMC 21.45
—
Minimum lot size
Not set UPMC 21.45
Binding site plan UPMC 21.40.050(A) A
Maximum lots
Not set UPMC 21.40
—
Minimum lot size
Not set UPMC 19.45.100

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Building height is at most 45
  2. Building height is more than 45
  3. None of these is true:
    • Multifamily project receives WSHFC approval for a low income housing tax credit and follows the Chapter 19.53 design standards
  4. Multifamily project receives WSHFC approval for a low income housing tax credit and follows the Chapter 19.53 design standards
  5. None of these is true:
    • The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
  6. All of these are true:
    • The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
    • The subject parcel is in a transition properties overlay
  7. All of these are true:
    • The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
    • The abutting R1 or R2 parcels are part of the project site
    None of these is true:
    • The subject parcel is in a transition properties overlay
  8. All of these are true:
    • The parcel abuts an R1 or R2 zone (the rule applies along the abutting lot line or portion)
    None of these is true:
    • The subject parcel is in a transition properties overlay
    • The abutting R1 or R2 parcels are part of the project site
  9. The building or area is within 100 feet of the ordinary high water mark
  10. None of these is true:
    • The building or area is within 100 feet of the ordinary high water mark
  11. All of these are true:
    • The building or area is within 100 feet of the ordinary high water mark
    None of these is true:
    • The project restores or enhances the vegetation conservation area per UPMC 18.25.100
  12. All of these are true:
    • The building or area is within 100 feet of the ordinary high water mark
    • The project restores or enhances the vegetation conservation area per UPMC 18.25.100
  13. None of these is true:
    • The building or area is within 100 feet of the ordinary high water mark
    • The project restores or enhances the vegetation conservation area per UPMC 18.25.100
  14. All of these are true:
    • The project restores or enhances the vegetation conservation area per UPMC 18.25.100
    None of these is true:
    • The building or area is within 100 feet of the ordinary high water mark
  15. Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
  16. All of these are true:
    • Bedrooms in one unit is less than 2
    None of these is true:
    • Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
  17. All of these are true:
    • Bedrooms in one unit is at least 2
    • Bedrooms in one unit is at most 2
    None of these is true:
    • Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)
  18. All of these are true:
    • Bedrooms in one unit is at least 3
    None of these is true:
    • Within one-quarter mile of a transit stop served at least four times per hour or 12 or more hours per day (transit proximity multifamily)