R2 · High density residential—R2 zone
Tieton, WA · TMC 17.12 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, single-family | Home✓ ADU✓ | — | — | — | — |
| Mobile/manufactured home | — | — | — | — | |
| Dwelling, duplex | — | Home✓ ADU— | — | — | — |
| Townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Cottage housing | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Dwelling, triplex | — | — | Home✓ ADU— | — | — |
| Dwelling, fourplex | — | — | — | Home✓ ADU— | — |
| Dwelling, multifamily | — | — | — | Home✓ ADU— | — |
| Mobilehome park | — | — | — | HomeH ADU— | — |
| Boarding houses | — | — | — | — | HomeH ADU— |
| Hospitals and health clinics including nursing homes | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set TMC 17.12.040 | 4 units TMC 17.04.080(C)
for Dwelling, fourplex (4+ units) |
| Minimum units | Not set TMC 17.12.040 | 5 units TMC 17.04.080(C)
for Dwelling, multifamily (4+ units) 8 units TMC 17.32.020(B)
for Mobilehome park (4+ units) |
| Minimum lot size | 7,200 + (1,800 × (main dwelling units on the lot − 2)) sq ft TMC 17.12.040(A)(2) | 5,000 sq ft TMC 17.12.040(A)(1)
7,200 sq ft TMC 17.12.040(A)(2)
for Dwelling, duplex (2 units) 3,600 × main dwelling units on the lot sq ft TMC 17.32.020(B)
for Mobilehome park (4+ units) Not set TMC 17.12.040(A)
for Boarding houses (group living); Hospitals and health clinics including nursing homes (group living) |
| Minimum lot width | 50 ft TMC 17.12.040(B) | |
| Minimum lot depth | 100 ft TMC 17.12.040(C) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft TMC 17.12.040(E) | |
| Side setback | 7 ft TMC 17.12.040(F) | |
| Rear setback | 15 ft TMC 17.12.040(G) | |
| Maximum height | 30 ft TMC 17.12.040(H) | |
| Maximum lot coverage | 40% TMC 17.12.040(D) | |
| Minimum parking | 1.5 spaces per unit TMC 17.36.020(A)(2) | 2 spaces per unit TMC 17.36.020(A)(1)
for Dwelling, single-family (1 unit); Mobile/manufactured home (1 unit)1; Dwelling, duplex (2 units); Mobilehome park (4+ units) Requirements for buildings and uses not specifically listed herein shall be determined by the planning commission whose decision shall be based upon the requirements of comparable listed uses within the subject zone. TMC 17.36.010(C)
for Boarding houses (group living); Hospitals and health clinics including nursing homes (group living) |
| Maximum unit size | Not set TMC 17.12.040 | 1,200 sq ft TMC 17.12.010(C); 17.04.080(C)
for Cottage housing (2, 3, 4+ units) |
| Minimum open space | Not set TMC 17.12.040 | 10% TMC 17.32.020(D)
for Mobilehome park (4+ units) |
4. ADU standards
Lot
No standards.
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft TMC 17.12.040(E) | |
| Side setback | 7 ft TMC 17.12.040(F) | |
| Rear setback | ||
| Maximum height | 30 ft TMC 17.12.040(H) | |
| Minimum parking | 1.5 spaces per unit TMC 17.36.020(A)(2) | |
| Maximum unit size | 900 sq ft TMC 17.04.080(C) | |
| Attached to the main house | Not required TMC 17.04.080(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TMC 16.08.010(B); 16.08.050(A) | A | up to 4 TMC 16.04.090(D); 16.08.010(A) | — | Minimum lot size 5,000 sq ft TMC 17.12.040(A)(1); 16.16.020(A)(4) Minimum lot width 50 ft TMC 17.12.040(B); 16.16.020(A)(4) Minimum lot depth 100 ft TMC 17.12.040(C); 16.16.020(A)(4) Minimum frontage Each lot shall have direct access to a street and front on an approved dedicated public street. The city may waive this requirement provided access to a public street is secured by a permanent access easement not less than twenty (20) feet in width and, further provided, the access easement shall not be disruptive to existing traffic patterns or cause undue traffic congestion. TMC 16.16.020(A)(1) |
| Subdivision TMC 16.12.010(2); 16.12.050(A) | H | 5 or more TMC 16.04.090(D); 16.12.010(1) | — | Minimum lot size 5,000 sq ft TMC 17.12.040(A)(1); 16.16.020(A)(4) Minimum lot width 50 ft TMC 17.12.040(B); 16.16.020(A)(4) Minimum lot depth 100 ft TMC 17.12.040(C); 16.16.020(A)(4) Minimum frontage Each lot shall have direct access to a street and front on an approved dedicated public street. The city may waive this requirement provided access to a public street is secured by a permanent access easement not less than twenty (20) feet in width and, further provided, the access easement shall not be disruptive to existing traffic patterns or cause undue traffic congestion. TMC 16.16.020(A)(1) |
| Binding site plans TMC 16.14.090(A)-(C) | A6 | Maximum lots Not set TMC 16.14.020 |
— | Minimum lot size 5,000 sq ft TMC 17.12.040(A)(1); 16.14.120(A) Minimum lot width 50 ft TMC 17.12.040(B); 16.14.120(A) Minimum lot depth 100 ft TMC 17.12.040(C); 16.14.120(A) Minimum frontage Each lot shall have direct access to a street and front on an approved dedicated public street. The city may waive this requirement provided access to a public street is secured by a permanent access easement not less than twenty (20) feet in width and, further provided, the access easement shall not be disruptive to existing traffic patterns or cause undue traffic congestion. TMC 16.16.020(A)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The manufactured home is not more than ten (10) years of age from the date of placement
- The single-family dwelling is in an approved zero lot line development, on its own platted lot
- None of these is true:
- The single-family dwelling is in an approved zero lot line development, on its own platted lot
- The building is an accessory building detached from the primary residential structure
- None of these is true:
- The building is an accessory building detached from the primary residential structure
- The land is subject to Chapter 64.32 RCW (Horizontal Property Regimes Act) or Chapter 64.34 RCW (Washington Condominium Act)