1 unit2 units3 units4+ unitsGroup living
Dwelling, Single-Family
Home✓ ADU✓1 ✓2 ✓3 ✓4 ✓5 ✓6 ✓7 ✓8 ✓9 H10
————
Supportive Housing, Permanent
Home✓ ADU✓9
Home✓ ADU✓9
Home✓ ADU✓9
Home✓ ADU✓9
—
Dwelling, Duplex (two-family dwelling)—
Home✓ ADU✓9
———
Mobile or manufactured home park—
Home✓ ADU✓9
Home✓ ADU✓9
Home✓ ADU✓9
—
Supportive Housing, Transitional————
Home✓ ADU✓9
Residential care facility————
Home✓ ADU✓9
Secure community transition facility————
HomeH11 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set TCC 20.09A.050
4 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units)
Minimum unitsNot set TCC 20.09A.050
2 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units)
5 units TCC 20.31.020(2); 20.54.070(21.6)
for Mobile or manufactured home park (4+ units)
Minimum lot size
  • 2,400 × main dwelling units on the lot sq ft12 TCC 20.31.030(11)(a)
  • 3,600 × main dwelling units on the lot sq ft13 TCC 20.31.030(11)(b)
  • 4,800 × main dwelling units on the lot sq ft14 TCC 20.31.030(11)(c)
  • 217,800 sq ft15 TCC 20.09A.050(2)(a)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.16 TCC 20.56.020(2)
for Dwelling, Single-Family (1 unit)
  • 217,800 sq ft17 TCC 20.09A.050(2)(a)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.18 TCC 20.56.020(2)
for Supportive Housing, Permanent (1 unit); Dwelling, Duplex (two-family dwelling) (2 units); Supportive Housing, Transitional (group living)
Not set TCC 20.09A.050
for Supportive Housing, Permanent (2, 3, 4+ units)
the largest of 217,800, 12,500 sq ft TCC 20.09A.050(2)(a); 20.54.070(34)(d)
for Residential care facility (group living)
the largest of 217,800, 12,500, 12,000 + (1,000 × (residents − 10)) sq ft TCC 20.09A.050(2)(a); 20.54.070(34)(d)
for Residential care facility (group living)19
217,800 sq ft TCC 20.09A.050(2)(c)
for Secure community transition facility (group living)11
Maximum density1 unit per 217,800 sq ft, on the net lot area TCC 20.09A.040; 20.09A.040(2)(a)-(c)
  • 1 unit per 217,800 sq ft, on the net lot area15 TCC 20.09A.040; 20.09A.040(2)(a)-(c)
  • Legal lots, as defined under Section 18.04.045 of this code, not subject to the exception in subsection (1) of this section may be developed for uses and in the manner permitted by this title and amendments thereto even though the lot fails to meet lot area and width standards prescribed by this title for the lot.16 TCC 20.56.020(2)
for Dwelling, Single-Family (1 unit)
Maximum residentsNot set TCC 20.09A.050
5 persons TCC 20.54.070(34)(a)
for Residential care facility (group living)
20 persons TCC 20.54.070(34)(c)
for Residential care facility (group living)19
  • 3 persons20 TCC 20.54.070(39.5)(a)
  • 6 persons21 TCC 20.54.070(39.5)(a)
for Secure community transition facility (group living)11

3. Building standards

StandardValueExceptions
Front setback
  • 25 ft22 TCC 20.09A.050(5); 20.07.030(1)
  • 20 ft23 TCC 20.09A.050(5); 20.07.030(1)
  • the largest of 60 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft22 TCC 20.31.030(4)(a)(iii)-(iv)
  • the largest of 50 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft23 TCC 20.31.030(4)(a)(iii)-(iv)
for Mobile or manufactured home park (2, 3, 4+ units)
Side setback5 ft TCC 20.09A.050(5); 20.07.030(1)
10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units)
Street side setback10 ft TCC 20.09A.050(5); 20.07.030(1)
  • the largest of 60 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft22 TCC 20.31.030(4)(a)(iii)-(iv)
  • the largest of 50 − (width of the street right-of-way in front of the lot ÷ 2), 20 ft23 TCC 20.31.030(4)(a)(iii)-(iv)
for Mobile or manufactured home park (2, 3, 4+ units)
Rear setback5 ft TCC 20.09A.050(5); 20.07.030(1)
10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units)
Building separationNot set TCC 20.09A.050
10 ft TCC 20.31.030(4)(b)
for Mobile or manufactured home park (2, 3, 4+ units)
Maximum height35 ft TCC 20.09A.050(4); 20.07.080
Maximum impervious surface
  • the smallest of 45, (10,000 ÷ lot area) × 100%24 TCC 20.09A.050(6)(a)(i)
  • 6%25 TCC 20.09A.050(6)(a)(ii)
  • 10%26 TCC 20.09A.050(6)(b)(i)
  • the smallest of 60, (10,000 ÷ lot area) × 100%27 TCC 20.09A.050(6)(b)(ii)
Minimum parking1 space per unit TCC 20.44.030(1)(a)(i)
(2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces TCC 20.31.030(5)(a)-(b)
for Mobile or manufactured home park (2, 3, 4+ units)
  • 1 space per unit28 TCC 20.44.030(1)(a)(i)-(ii)
  • 0 spaces per unit29 TCC 20.44.030(1)(a)(iii)
for Supportive Housing, Permanent (4+ units)
1 + employees on the largest shift spaces TCC 20.54.070(34)(e); 20.44.030(1)(a)(i)
for Residential care facility (group living); Residential care facility (group living)19
The off-street parking requirements for uses not specifically mentioned in this section shall be the same as the use most similar from the standpoint of parking needs TCC 20.44.030(3)
for Secure community transition facility (group living)11

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units TCC 20.09A.020(6)(b)
1 unit TCC 20.34.020(1)
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Single-Family (1 unit)3; Dwelling, Single-Family (1 unit)4
3 units TCC 20.09A.020(6)(c)
for Dwelling, Single-Family (1 unit)6
4 units TCC 20.09A.020(6)(d)
for Dwelling, Single-Family (1 unit)7; Dwelling, Single-Family (1 unit)8
(lot area ÷ 871,200, rounded down) + 1 units TCC 20.09A.020(6)(e); TCC 20.09A.020(6)(a)-(d)
for Dwelling, Single-Family (1 unit)10
Minimum lot size0 sq ft TCC 20.34.020(2)(a)
217,800 sq ft TCC 20.09A.020(6)(a)
for Dwelling, Single-Family (1 unit)4
871,200 sq ft TCC 20.09A.020(6)(b)
for Dwelling, Single-Family (1 unit)5
1,742,400 sq ft TCC 20.09A.020(6)(c)
for Dwelling, Single-Family (1 unit)6
2,613,600 sq ft TCC 20.09A.020(6)(d)
for Dwelling, Single-Family (1 unit)7
3,484,800 sq ft TCC 20.09A.020(6)(e)
for Dwelling, Single-Family (1 unit)8; Dwelling, Single-Family (1 unit)10

Building

StandardValueExceptions
Front setback
  • 25 ft22 TCC 20.34.020(3); TCC 20.09A.050(5); 20.07.030(1)
  • 20 ft23 TCC 20.34.020(3); TCC 20.09A.050(5); 20.07.030(1)
Side setback5 ft TCC 20.34.020(3); TCC 20.09A.050(5); 20.07.030(1)
Rear setback5 ft TCC 20.34.020(3); TCC 20.09A.050(5); 20.07.030(1)
Maximum height35 ft TCC 20.34.020(3); TCC 20.09A.050(4); 20.07.080
Minimum parking1 space per unit TCC 20.34.050(6)
Maximum unit size1,000 sq ft TCC 20.34.040(4)(a)
0.5 × floor area of the main house sq ft TCC 20.34.020(4)(a)
for Dwelling, Single-Family (1 unit)1
No limit TCC 20.34.020(4)(b)
for Dwelling, Single-Family (1 unit)2
  • 1,000 sq ft30 TCC 20.34.020(4)(c)
  • 1,200 sq ft31 TCC 20.34.020(4)(c)(i)
for Dwelling, Single-Family (1 unit)3
Not set TCC 20.09A.020(6)
for Dwelling, Single-Family (1 unit)4; Dwelling, Single-Family (1 unit)5; Dwelling, Single-Family (1 unit)6; Dwelling, Single-Family (1 unit)7; Dwelling, Single-Family (1 unit)8; Dwelling, Single-Family (1 unit)10
Attached to the main houseNot required TCC 20.03.040(37.1)(b); 20.34.020(4)(b)
Required TCC 20.03.040(37.1)(a)
for Dwelling, Single-Family (1 unit)1
Not set TCC 20.09A.020(6)
for Dwelling, Single-Family (1 unit)4; Dwelling, Single-Family (1 unit)5; Dwelling, Single-Family (1 unit)6; Dwelling, Single-Family (1 unit)7; Dwelling, Single-Family (1 unit)8; Dwelling, Single-Family (1 unit)10

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Large lot subdivision TCC 18.28.010; 18.28.030(B); 20.60.020 Table 2 A 2 or more TCC 18.08.183; 18.28.010 1 unit per 217,800 sq ft, on the net lot area TCC 20.09A.040; 20.09A.040(2)(a)-(c)
Minimum lot size
217,800 sq ft TCC 20.09A.050(1)(a); 20.09A.050(2)(a)
Planned rural residential development (PRRD) TCC 20.30A.080; 20.30A.020(4); 20.60.020 Table 2; 18.32.010; 18.32.140(D) A up to 4 TCC 18.08.280; 18.32.010
  • 1 unit per 217,800 sq ft, on the net lot area32 TCC 20.09A.040; 20.09A.040(2)(a)-(c)
  • 0.32 units per acre, on the net lot area33 TCC 20.30A.060(1)(b); 20.30A.060(2)(b)
Minimum parent area
871,200 sq ft TCC 20.30A.031(1)
Maximum parent area
4,356,000 sq ft TCC 20.30A.031(2)
Minimum lot size
No limit TCC 20.30A.070(1); 20.09A.050(1)(b); 20.09A.050(2)(b)
Planned rural residential development (PRRD) TCC 20.30A.080; 20.30A.020(4); 20.60.020 Table 2; 18.12.090; 20.60.020 Table 2 H 5 or more TCC 18.08.310
  • 1 unit per 217,800 sq ft, on the net lot area32 TCC 20.09A.040; 20.09A.040(2)(a)-(c)
  • 0.32 units per acre, on the net lot area33 TCC 20.30A.060(1)(b); 20.30A.060(2)(b)
Minimum parent area
871,200 sq ft TCC 20.30A.031(1)
Maximum parent area
4,356,000 sq ft TCC 20.30A.031(2)
Minimum lot size
No limit TCC 20.30A.070(1); 20.09A.050(1)(b); 20.09A.050(2)(b)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is adu_attached
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  2. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is adu_conversion
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  3. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is adu_detached
    • A detached ADU on the lot is consistent with historical rural density patterns, as calculated by the department
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  4. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is farm_housing
    • The property meets the definition of a farm in RCW 84.34.020
    • The dwelling on the property is the farm residence (the single-family dwelling which is the primary dwelling for a farm)
    • Lot area is at least 217,800 sf
    • Lot area is less than 871,200 sf
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  5. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is farm_housing
    • The property meets the definition of a farm in RCW 84.34.020
    • The dwelling on the property is the farm residence (the single-family dwelling which is the primary dwelling for a farm)
    • Lot area is at least 871,200 sf
    • Lot area is less than 1,742,400 sf
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  6. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is farm_housing
    • The property meets the definition of a farm in RCW 84.34.020
    • The dwelling on the property is the farm residence (the single-family dwelling which is the primary dwelling for a farm)
    • Lot area is at least 1,742,400 sf
    • Lot area is less than 2,613,600 sf
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  7. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is farm_housing
    • The property meets the definition of a farm in RCW 84.34.020
    • The dwelling on the property is the farm residence (the single-family dwelling which is the primary dwelling for a farm)
    • Lot area is at least 2,613,600 sf
    • Lot area is less than 3,484,800 sf
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  8. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is farm_housing
    • The property meets the definition of a farm in RCW 84.34.020
    • The dwelling on the property is the farm residence (the single-family dwelling which is the primary dwelling for a farm)
    • Lot area is at least 3,484,800 sf
    • ADUs on the lot is at most 4
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  9. The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  10. All of these are true:
    • Which one accessory dwelling the owner adds: attached ADU, ADU conversion, detached ADU, family member unit, or farm housing is farm_housing
    • The property meets the definition of a farm in RCW 84.34.020
    • The dwelling on the property is the farm residence (the single-family dwelling which is the primary dwelling for a farm)
    • Lot area is at least 3,484,800 sf
    • ADUs on the lot is more than 4
    None of these is true:
    • The lot is within the Yelm, Rainier or Tenino urban growth area (layer Jurisdiction YELMUGA, RAINUGA or TENUGA)
  11. All of these are true:
    • Any of these is true:
      • None of these is true:
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a school (public or private) or a school site owned by a school district or private school and planned for school development in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a licensed pre-school in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a licensed child care home or day care center in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a sports field, playground or public park in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a church, synagogue, temple or mosque in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a recreational or community center in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a school bus stop in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a public library in existence when the site is applied for
        • The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a publicly dedicated trail in existence when the site is applied for
      • Waterbodies, bluffs, freeways or a similar barrier effectively preclude access from the site to the separated uses
      • Following a public hearing, the hearing examiner reduces the separation standards of subsection (b) on the applicant's request, because no site is available that meets them
    • Any of these is true:
      • None of these is true:
        • The site is within five hundred feet of a residence or a vacant residential lot
      • The applicant obtains development rights or easements that preclude the siting of a residence within five hundred feet of the facility
      • Waterbodies, bluffs, freeways or a similar barrier effectively preclude access from the site to the separated uses
      • Following a public hearing, the hearing examiner reduces the separation standards of subsection (b) on the applicant's request, because no site is available that meets them
    • Any of these is true:
      • No site is available in any district with a higher siting preference (in order: long-term forestry, military reservation, industrial, commercial) than the district of the proposed site
      • The proposed site would pose less of a public safety risk than alternative sites
    • Any of these is true:
      • The proposed site would pose less of a public safety risk than alternative sites
      • No site meeting the secure community transition facility requirements is available in other zoning districts
  12. Width class of the mobile/manufactured homes placed in the park is single_wide
  13. Width class of the mobile/manufactured homes placed in the park is double_wide
  14. Width class of the mobile/manufactured homes placed in the park is triple_wide
  15. Not all of these are true:
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 217,800 sf
  16. All of these are true:
    • The lot is a legal lot under TCC 18.04.045
    • Lot area is less than 217,800 sf
  17. None of these is true:
    • The lot is a legal lot under TCC 18.04.045
  18. The lot is a legal lot under TCC 18.04.045
  19. Residents is more than 5
  20. Not all of these are true:
    • The state requires the county to accommodate additional committed sex offenders
    • The hearing examiner authorizes up to a total of six offenders in the secure community transition facility, on a request processed under Chapter 20.54
  21. All of these are true:
    • The state requires the county to accommodate additional committed sex offenders
    • The hearing examiner authorizes up to a total of six offenders in the secure community transition facility, on a request processed under Chapter 20.54
  22. The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
  23. None of these is true:
    • The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
  24. All of these are true:
    • The lot is within the Green Cove Creek Drainage Basin
    • Lot area is less than 174,240 sf
  25. All of these are true:
    • The lot is within the Green Cove Creek Drainage Basin
    • Lot area is at least 174,240 sf
  26. All of these are true:
    • Lot area is at least 108,900 sf
    None of these is true:
    • The lot is within the Green Cove Creek Drainage Basin
  27. All of these are true:
    • Lot area is less than 108,900 sf
    None of these is true:
    • The lot is within the Green Cove Creek Drainage Basin
  28. Main dwelling units on the lot is at most 4
  29. Main dwelling units on the lot is more than 4
  30. None of these is true:
    • One transferable development right is purchased from the Long-Term Agriculture District under Chapter 20.62
  31. One transferable development right is purchased from the Long-Term Agriculture District under Chapter 20.62
  32. None of these is true:
    • The PRRD uses a conservation or small-home cluster density bonus with retired development rights
  33. The PRRD uses a conservation or small-home cluster density bonus with retired development rights