R5-12/1 · Residential—Five to Twelve Dwelling Units per Acre (R 5-12/1)
Thurston County, WA · TCC 20.15 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | Home✓ ADU✓ | — | — | — | — |
| Supportive Housing, Permanent | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Dwelling, Duplex (two-family dwelling) | — | Home✓ ADU✓ | — | — | — |
| Mobile or manufactured home park | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Cottage housing | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Dwelling, Triplex | — | — | Home✓ ADU✓ | — | — |
| Planned residential development | — | — | — | HomeH ADU✓ | — |
| Supportive Housing, Transitional | — | — | — | — | Home✓ ADU✓ |
| Residential care facility | — | — | — | — | Home✓ ADU✓ |
| Nursing or convalescent home | — | — | — | — | HomeH ADU✓ |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set TCC 20.15.060 | 4 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units) |
| Minimum units | Not set TCC 20.15.060 | 2 units TCC 20.31.020(1)
for Mobile or manufactured home park (4+ units); Cottage housing (4+ units) 5 units TCC 20.31.020(2); 20.54.070(21.6)
for Mobile or manufactured home park (4+ units) |
| Minimum lot size | Not set TCC 20.15.060 |
for Dwelling, Single-Family (1 unit)
for Supportive Housing, Permanent (1 unit); Supportive Housing, Transitional (group living)
for Dwelling, Duplex (two-family dwelling) (2 units) for Mobile or manufactured home park (2, 3, 4+ units)
for Dwelling, Triplex (3 units) No limit TCC 20.30.050(3)
for Planned residential development (4+ units) for Residential care facility (group living)
for Residential care facility (group living)18 20,000 sq ft TCC 20.15.060(1)(c); 20.54.040(2)
for Nursing or convalescent home (group living) |
| Minimum lot width |
|
for Mobile or manufactured home park (2, 3, 4+ units); Residential care facility (group living); Residential care facility (group living)18; Nursing or convalescent home (group living) No limit TCC 20.30.040(1)
for Planned residential development (4+ units) |
| Minimum density | ||
| Maximum density | 12 units per acre TCC 20.15.050(2) |
for Dwelling, Single-Family (1 unit) for Cottage housing (2, 3, 4+ units) |
| Minimum development size | Not set TCC 20.15.060 | 43,560 sq ft TCC 20.30.050(2)(a)(i)
for Planned residential development (4+ units) |
| Maximum residents | Not set TCC 20.15.060 | 5 persons TCC 20.54.070(34)(a)
for Residential care facility (group living) 20 persons TCC 20.54.070(34)(c)
for Residential care facility (group living)18 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | for Mobile or manufactured home park (2, 3, 4+ units) 10 ft TCC 20.38.030(J)(1)
for Cottage housing (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units) | |
| Side setback | 5 ft TCC 20.15.060(5)(a); 20.07.030(1) | 10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units) |
| Street side setback | 10 ft TCC 20.15.060(5)(a); 20.07.030(1) | for Mobile or manufactured home park (2, 3, 4+ units) Not set TCC 20.38.030(J)
for Cottage housing (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units) |
| Rear setback | 5 ft TCC 20.15.060(5)(a); 20.07.030(1) | 10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (2, 3, 4+ units) Setbacks from the exterior boundary line of the PRD area shall be comparable to or compatible with those of the existing development of adjacent properties ... In no event shall such setback be less than twenty feet. TCC 20.30.050(7)(a)
for Planned residential development (4+ units) |
| Building separation | Not set TCC 20.15.060 | 10 ft TCC 20.31.030(4)(b)
for Mobile or manufactured home park (2, 3, 4+ units); Cottage housing (2, 3, 4+ units); Planned residential development (4+ units) |
| Maximum height | 35 ft TCC 20.15.060(4) | 25 ft TCC 20.38.030(I)(1)
for Cottage housing (2, 3, 4+ units) The specific setback, lot size, height limits and other dimensional requirements are waived, and the regulations for PRD's shall be those indicated in Section 20.30.060. TCC 20.30.040(1)
for Planned residential development (4+ units) |
| Maximum impervious surface | the smallest of 60, (20,000 ÷ lot area) × 100% TCC 20.15.060(6) | |
| Minimum parking | 1 space per unit TCC 20.44.030(1)(a)(i) | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces TCC 20.31.030(5)(a)-(b)
for Mobile or manufactured home park (2, 3, 4+ units) 1.5 spaces per unit TCC 20.38.030(L)(1)
for Cottage housing (2, 3, 4+ units) for Supportive Housing, Permanent (4+ units); Planned residential development (4+ units) 1 + employees on the largest shift spaces TCC 20.54.070(34)(e); 20.44.030(1)(a)(i)
0.2 spaces per bed TCC 20.44.030(1)(b)(v)
for Nursing or convalescent home (group living) |
| Maximum unit size | Not set TCC 20.15.060 | 1,200 sq ft TCC 20.38.030(D)
for Cottage housing (2, 3, 4+ units) |
| Maximum building footprint | Not set TCC 20.15.060 | 1,000 sq ft TCC 20.38.030(D)
for Cottage housing (2, 3, 4+ units) |
| Minimum open space | Not set TCC 20.15.060 | for Mobile or manufactured home park (2, 3, 4+ units) 20% TCC 20.38.030(G)
for Cottage housing (2, 3, 4+ units) 30% TCC 20.30.060(1)
for Planned residential development (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units TCC 20.34.040(1) | |
| Minimum lot size | 0 sq ft TCC 20.34.040(2)(a) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft TCC 20.34.040(3); TCC 20.15.060(5)(a); 20.07.030(1) | |
| Rear setback | 5 ft TCC 20.34.040(3); TCC 20.15.060(5)(a); 20.07.030(1) | |
| Maximum height | 35 ft TCC 20.34.040(3); TCC 20.15.060(4) | |
| Minimum parking | 1 space per unit TCC 20.34.050(6) | |
| Maximum unit size | 1,000 sq ft TCC 20.34.040(4)(a) | |
| Attached to the main house | Not required TCC 20.34.040(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TCC 18.32.010; 18.32.140(D) | A | up to 4 TCC 18.08.280; 18.32.010 | 12 units per acre TCC 20.15.050(2) Minimum density 5 units per acre TCC 20.15.050(1) |
Minimum lot width 50 ft TCC 20.15.060(2)(a)(i) |
| Subdivision TCC 18.12.090; 20.60.020 Table 2 | H | 5 or more TCC 18.08.310 | 12 units per acre TCC 20.15.050(2) Minimum density 5 units per acre TCC 20.15.050(1) |
Minimum lot width 50 ft TCC 20.15.060(2)(a)(i) |
| Cluster subdivision TCC 20.03.040(20); 18.32.010; 18.32.140(D) | A | up to 4 TCC 18.08.280; 18.32.010 | 12 units per acre TCC 20.15.050(2) Minimum density 5 units per acre TCC 20.15.050(1) |
Minimum lot size 3,000 sq ft TCC 20.15.060(1)(b) |
| Cluster subdivision TCC 20.03.040(20); 18.12.090; 20.60.020 Table 2 | H | 5 or more TCC 18.08.310 | 12 units per acre TCC 20.15.050(2) Minimum density 5 units per acre TCC 20.15.050(1) |
Minimum lot size 3,000 sq ft TCC 20.15.060(1)(b) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The lot is served by public sewer
- Not all of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 5,000 sf
- The lot is (or will be) a lot in a cluster subdivision
- All of these are true:
- The lot is served by public sewer
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 5,000 sf
- The lot is (or will be) a lot in a cluster subdivision
- All of these are true:
- Not all of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 13,000 sf
- The lot is (or will be) a lot in a cluster subdivision
- The lot is served by public sewer
- Not all of these are true:
- All of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 13,000 sf
- The lot is (or will be) a lot in a cluster subdivision
- The lot is served by public sewer
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- Not all of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 3,000 sf
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 3,000 sf
- All of these are true:
- The lot is served by public sewer
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- None of these is true:
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- The lot is served by public sewer
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- The lot is a legal lot under TCC 18.04.045
- The lot is a legal lot under TCC 18.04.045
- Width class of the mobile/manufactured homes placed in the park is single_wide
- Width class of the mobile/manufactured homes placed in the park is double_wide
- Width class of the mobile/manufactured homes placed in the park is triple_wide
- None of these is true:
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- All of these are true:
- The lot is served by public sewer
- The lot is (or will be) a lot in a cluster subdivision
- None of these is true:
- The lot is (or will be) a lot in a cluster subdivision
- The lot is served by public sewer
- The lot is (or will be) a lot in a cluster subdivision
- Residents is more than 5
- All of these are true:
- Corner lot
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- All of these are true:
- Lot fronting a cul-de-sac
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- All of these are true:
- Flag lot
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- Lot fronting a cul-de-sac
- None of these is true:
- The lot is a legal lot under TCC 18.04.045
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- Lot fronting a cul-de-sac
- Flag lot
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- The lot is a legal lot under TCC 18.04.045
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- The lot is a legal lot under TCC 18.04.045
- Corner lot
- All of these are true:
- Corner lot
- The lot is (or will be) a lot in a cluster subdivision
- All of these are true:
- Lot fronting a cul-de-sac
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- All of these are true:
- Flag lot
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- Lot fronting a cul-de-sac
- None of these is true:
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- Lot fronting a cul-de-sac
- Flag lot
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- All of these are true:
- The lot is (or will be) a lot in a cluster subdivision
- Corner lot
- None of these is true:
- Lot area is more than 43,560 sf
- None of these is true:
- The lot is served by public sewer
- Any of these is true:
- Lot area is more than 43,560 sf
- None of these is true:
- The lot is served by public sewer
- Not all of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 3,630 sf
- All of these are true:
- The lot is a legal lot under TCC 18.04.045
- Lot area is less than 3,630 sf
- None of these is true:
- All cottages are built under a green building certificate program (LEED, Passive House, Four Star Built Green)
- All cottages are built under a green building certificate program (LEED, Passive House, Four Star Built Green)
- None of these is true:
- The PRD provides the open space amenities that qualify for the density bonus
- The PRD provides the open space amenities that qualify for the density bonus
- The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
- None of these is true:
- The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
- Main dwelling units on the lot is at most 4
- Main dwelling units on the lot is more than 4
- Lot area is at least 435,600 sf
- Lot area is less than 435,600 sf
- The lot is served by public sewer
- None of these is true:
- The lot is served by public sewer