AC · Arterial Commercial District (AC)
Thurston County, WA · TCC 20.25 · Official code
By right: 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Residence in conjunction with a permitted use | — | — | — | — | |
| Dwelling, Multiple Family | — | — | |||
| Supportive Housing, Permanent | — | — | |||
| Mobile or manufactured home park | — | — | — | — | |
| Supportive Housing, Shelter (emergency shelter) | — | — | — | — | Home✓ ADU— |
| Supportive Housing, Emergency (emergency housing) | — | — | — | — | Home✓ ADU— |
| Supportive Housing, Transitional | — | — | — | — | Home✓ ADU— |
| Secure community transition facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set TCC 20.25.020(9) | 5 units TCC 20.54.070(21.6); 20.31.020(2)
for Mobile or manufactured home park (4+ units) |
| Minimum lot size |
|
for Mobile or manufactured home park (4+ units) 10,000 sq ft TCC 20.25.040(1); 20.21A.060(1)(a)
for Secure community transition facility (group living)4 |
| Minimum lot width |
|
|
| Minimum density | 8 units per acre TCC 20.25.030(1); 20.21A.050(1) | Not set TCC 20.25.030(1)
|
| Maximum density | 24 units per acre TCC 20.25.030(1); 20.21A.050(2) | for Dwelling, Multiple Family (3, 4+ units) subject to the permitted density of this district or the permitted occupancy adopted by the building code for similar uses TCC 20.25.020(33)
for Supportive Housing, Shelter (emergency shelter) (group living); Supportive Housing, Emergency (emergency housing) (group living); Supportive Housing, Transitional (group living) Not set TCC 20.25.030
for Secure community transition facility (group living)4 |
| Maximum residents | subject to the permitted density of this district or the permitted occupancy adopted by the building code for similar uses TCC 20.25.020(33) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft TCC 20.25.040(5)(b); 20.21A.060(5); 20.07.030(1) | 10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (4+ units) |
| Street side setback | 10 ft TCC 20.25.040(5)(b); 20.21A.060(5); 20.07.030(1) | |
| Rear setback | 5 ft TCC 20.25.040(5)(b); 20.21A.060(5); 20.07.030(1) | 10 ft TCC 20.31.030(4)(a)(ii)
for Mobile or manufactured home park (4+ units) |
| Building separation | Not set TCC 20.25.040 | 10 ft TCC 20.31.030(4)(b)
for Mobile or manufactured home park (4+ units) |
| Maximum height | 45 ft TCC 20.25.040(4); 20.21A.060(4) | |
| Maximum impervious surface | ||
| Minimum parking | The off-street parking requirements for uses not specifically mentioned in this section shall be the same as the use most similar from the standpoint of parking needs TCC 20.44.030(3) | 1 space per unit TCC 20.44.030(1)(a)(i)
for Residence in conjunction with a permitted use (1 unit)1 for Dwelling, Multiple Family (2, 3, 4+ units) (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces TCC 20.31.030(5)(a)-(b)
for Mobile or manufactured home park (4+ units) |
| Minimum open space |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units TCC 20.34.040(1) | |
| Minimum lot size | 10,000 sq ft TCC 20.34.040(2)(a); 20.25.040(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft TCC 20.34.040(3); 20.25.040(5)(b); 20.07.030(1) | |
| Rear setback | 5 ft TCC 20.34.040(3); 20.25.040(5)(b); 20.07.030(1) | |
| Maximum height | 45 ft TCC 20.34.040(3); 20.25.040(4) | |
| Minimum parking | 1 space per unit TCC 20.34.050(6) | |
| Maximum unit size | 1,000 sq ft TCC 20.34.040(4)(a) | |
| Attached to the main house | Not required TCC 20.34.040(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TCC 18.32.010; 18.32.140(D) | A | up to 4 TCC 18.08.280; 18.32.010 | — | Minimum lot size 10,000 sq ft TCC 20.25.040(1); 20.21A.060(1)(a) |
| Subdivision TCC 18.12.090; 20.60.020(1) | H | 5 or more TCC 18.08.310 | — | Minimum lot size 10,000 sq ft TCC 20.25.040(1); 20.21A.060(1)(a) |
| Large lot subdivision TCC 18.28.030; 20.60.020(1) | A | 2 or more TCC 18.28.010 | — | Minimum lot size 217,800 sq ft TCC 18.08.183; 18.28.010 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The residence is built in conjunction with a permitted (listed) nonresidential use on the same site
- All of these are true:
- The residence is built in conjunction with a permitted (listed) nonresidential use on the same site
- Lot is within the Grand Mound Urban Growth Area
- Lot is within the Grand Mound Urban Growth Area
- All of these are true:
- Any of these is true:
- None of these is true:
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a school (public or private) or a school site owned by a school district or private school and planned for school development in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a licensed pre-school in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a licensed child care home or day care center in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a sports field, playground or public park in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a church, synagogue, temple or mosque in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a recreational or community center in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a school bus stop in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a public library in existence when the site is applied for
- The site is adjacent to, immediately across a street or parking lot from, or within the line of sight of a publicly dedicated trail in existence when the site is applied for
- Waterbodies, bluffs, freeways or a similar barrier effectively preclude access from the site to the separated uses
- Following a public hearing, the hearing examiner reduces the separation standards of subsection (b) on the applicant's request, because no site is available that meets them
- None of these is true:
- Any of these is true:
- None of these is true:
- The site is within five hundred feet of a residence or a vacant residential lot
- The applicant obtains development rights or easements that preclude the siting of a residence within five hundred feet of the facility
- Waterbodies, bluffs, freeways or a similar barrier effectively preclude access from the site to the separated uses
- Following a public hearing, the hearing examiner reduces the separation standards of subsection (b) on the applicant's request, because no site is available that meets them
- None of these is true:
- Any of these is true:
- No site is available in any district with a higher siting preference (in order: long-term forestry, military reservation, industrial, commercial) than the district of the proposed site
- The proposed site would pose less of a public safety risk than alternative sites
- Any of these is true:
- None of these is true:
- The lot is a legal lot under TCC 18.04.045
- The lot is a legal lot under TCC 18.04.045
- Width class of the mobile/manufactured homes placed in the park is single_wide
- Width class of the mobile/manufactured homes placed in the park is double_wide
- Width class of the mobile/manufactured homes placed in the park is triple_wide
- All of these are true:
- Lot is within the Grand Mound Urban Growth Area
- The lot is a legal lot under TCC 18.04.045
- Corner lot
- All of these are true:
- Lot is within the Grand Mound Urban Growth Area
- Corner lot
- The lot is a legal lot under TCC 18.04.045
- None of these is true:
- The lot is a legal lot under TCC 18.04.045
- Lot is within the Grand Mound Urban Growth Area
- All of these are true:
- Lot is within the Grand Mound Urban Growth Area
- Corner lot
- All of these are true:
- Lot is within the Grand Mound Urban Growth Area
- Corner lot
- None of these is true:
- Lot is within the Grand Mound Urban Growth Area
- Not all of these are true:
- Lot is within the Grand Mound Urban Growth Area
- The multifamily development provides EV charging stations for 25% of total parking spaces
- All of these are true:
- Lot is within the Grand Mound Urban Growth Area
- The multifamily development provides EV charging stations for 25% of total parking spaces
- Not all of these are true:
- The state requires the county to accommodate additional committed sex offenders
- The hearing examiner authorizes up to a total of six offenders in the secure community transition facility, on a request processed under Chapter 20.54
- All of these are true:
- The state requires the county to accommodate additional committed sex offenders
- The hearing examiner authorizes up to a total of six offenders in the secure community transition facility, on a request processed under Chapter 20.54
- The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
- None of these is true:
- The front yard faces an arterial, state highway or railroad right-of-way (not a collector, local or private road)
- The lot fronts on an arterial (adopted arterial street map)
- None of these is true:
- The lot fronts on an arterial (adopted arterial street map)
- Main dwelling units on the lot is at most 4
- Main dwelling units on the lot is more than 4