Sign in

MF · Multi-family residential (MF) zone

Tenino, WA · TMC 106.30.040 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Single-Family Unit
Home✓ ADUA
————
Attached Single-Family Unit
Home✓1 ADU—
Home✓1 ADU—
Home✓ ADU—
Home✓ ADU—
—
Duplex—
Home✓ ADU—
———
Group Home————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot width20 ft TMC 106.30.040(D)(1)(a)
Minimum lot depth55 ft TMC 106.30.040(D)(1)(b)
Minimum frontage
  • Flag lots in residential zones (SF-ES, SF, SF-D, and MF) shall have a minimum frontage of 20 feet on a public road or street from which access is taken. If such frontage does not exist, an easement to a public road or street shall be a minimum of 20 feet in width.2 TMC 108.30.040(E)(1)
  • Not set3 TMC 106.30.040(D)(1)
Maximum density
  • Individual water and septic: Defers to Thurston County standards.4 TMC 106.30.040(D)(2)(a)
  • Public water and individual septic: Defers to Thurston County standards.5 TMC 106.30.040(D)(2)(b)
  • 40 units per acre, on the net lot area6 TMC 106.30.040(D)(2)(c); 108.30.030(A)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft7 TMC 106.30.040(B)(1)
  • Averaging may be used to reduce a front yard setback requirement when a principal building has been established on an adjacent lot within the required yard. This provision shall not apply if the adjacent lot has received a reduced setback based upon a discretionary land use approval. Averaging shall be calculated by adding the existing front yard setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front yard setback of the adjacent developed lot with the minimum front yard setback of the zone in which the construction is proposed and dividing that figure by two.8 TMC 108.30.040(F); 108.30.040(F)(1)-(2)
Side setback
  • 0 ft9 TMC 106.30.040(F)(1)
  • 5 ft10 TMC 106.30.040(B)(1)
5 ft TMC 106.30.040(B)(1)
for Detached Single-Family Unit (1 unit); Duplex (2 units); Group Home (group living)
Street side setback10 ft TMC 106.30.040(B)(1); 108.30.040(B)-(C)
Rear setback10 ft TMC 106.30.040(B)(1)
Maximum height35 ft TMC 106.30.040(B)(6); 108.30.040(N)(1)
Maximum impervious surface60% TMC 106.30.040(B)(2)
Minimum parking1.5 spaces per unit TMC 106.30.040(C)(2); 108.50.020(A)
2 spaces per unit TMC 106.30.040(C)(2); 108.50.020(A)
for Detached Single-Family Unit (1 unit); Duplex (2 units)
0.5 spaces per bed TMC 106.30.040(C)(2); 108.50.020(A)
for Group Home (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit TMC 108.40.110(B)(3)(a); 108.40.110(B)(3)(b)

Building

StandardValueExceptions
Front setback
  • 10 ft7 TMC 106.30.040(B)(1); 108.40.110(A)(2)(c)
  • Averaging may be used to reduce a front yard setback requirement when a principal building has been established on an adjacent lot within the required yard. This provision shall not apply if the adjacent lot has received a reduced setback based upon a discretionary land use approval. Averaging shall be calculated by adding the existing front yard setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front yard setback of the adjacent developed lot with the minimum front yard setback of the zone in which the construction is proposed and dividing that figure by two.8 TMC 108.30.040(F); 108.30.040(F)(1)-(2)
Side setback5 ft TMC 106.30.040(B)(1); 108.40.110(A)(2)(c)
Rear setback10 ft TMC 106.30.040(B)(1); 108.40.110(A)(2)(c)
Maximum height35 ft TMC 106.30.040(B)(6); 108.40.110(A)(2)(c)
Minimum parking1 space per unit TMC 106.30.040(C)(2); 108.50.020(A)
Maximum unit size1,000 sq ft TMC 108.40.110(B)(3)(c)
Attached to the main houseNot required TMC 108.40.110(B)(3)(d)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision TMC 114.60.010; 100.40.070 A up to 4 TMC 114.10.040 —
Minimum lot size
Not set TMC 106.30.040(D)(1)
Minimum lot width
20 ft TMC 106.30.040(D)(1)(a)
Minimum lot depth
55 ft TMC 106.30.040(D)(1)(b)
Minimum frontage
  • Flag lots in residential zones (SF-ES, SF, SF-D, and MF) shall have a minimum frontage of 20 feet on a public road or street from which access is taken. If such frontage does not exist, an easement to a public road or street shall be a minimum of 20 feet in width.2 TMC 108.30.040(E)(1)
  • Not set3 TMC 106.30.040(D)(1)
Subdivision TMC 114.40.020; 114.40.030; 100.40.110 H 5 or more TMC 114.10.040 —
Minimum lot size
Not set TMC 106.30.040(D)(1)
Minimum lot width
20 ft TMC 106.30.040(D)(1)(a)
Minimum lot depth
55 ft TMC 106.30.040(D)(1)(b)
Minimum frontage
  • Flag lots in residential zones (SF-ES, SF, SF-D, and MF) shall have a minimum frontage of 20 feet on a public road or street from which access is taken. If such frontage does not exist, an easement to a public road or street shall be a minimum of 20 feet in width.2 TMC 108.30.040(E)(1)
  • Not set3 TMC 106.30.040(D)(1)
Residential condominium binding site plan TMC 114.90.010; 114.90.050; 114.90.060Only for: Attached Single-Family Unit A
Maximum lots
Not set TMC 114.90.040
Maximum units
Not set TMC 114.90.040(A)(1)
Minimum lot size
Not set TMC 114.90

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The building also has nonresidential units, so each dwelling unit is connected by common walls to at least two other dwelling or nonresidential units
  2. The lot is a pipestem or flag lot
  3. None of these is true:
    • The lot is a pipestem or flag lot
  4. Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
  5. Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_individual_septic
  6. Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_sewer
  7. None of these is true:
    • A principal building on an adjacent lot stands within the required front yard, and that lot did not get its reduced setback through a discretionary land use approval
  8. A principal building on an adjacent lot stands within the required front yard, and that lot did not get its reduced setback through a discretionary land use approval
  9. A row of townhouses or other attached dwelling units is built on different lots as part of the same development
  10. None of these is true:
    • A row of townhouses or other attached dwelling units is built on different lots as part of the same development