Sign in

UCX · Urban Center Mixed-Use District

Tacoma, WA · TMC 13.06.040 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-unit detached
Home✓1 ADU✓2
————
Dwelling, townhouse
Home✓1 ADU✓2
————
Live/Work
Home✓1 ADU✓2
Home✓1 ADU✓2
Home✓1 ADU✓2
Home✓1 ADU✓2
—
Work/Live
Home✓3 ADU✓4
Home✓3 ADU✓4
Home✓3 ADU✓4
Home✓3 ADU✓4
—
Dwelling, two-unit—
Home✓1 ADU✓2
———
Dwelling, three-unit——
Home✓1 ADU✓2
——
Dwelling, multi-unit———
Home✓1 ADU✓2
—
Retirement home———
Home✓3 ADU✓4
—
Group housing————
Home✓1 ADU✓2
Special needs housing————
Home✓1 ADU✓2
Permanent shelter————
Home✓1 ADU✓2
Confidential shelter————
Home✓1 ADU✓2
Juvenile community facility————
Home✓5 ADU✓6
Work release center————
HomeA7 ADU✓8
Temporary shelter————
Home✓9 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set TMC 13.06.040E.3
20 units TMC 13.06.040E.3
for Live/Work (4+ units)1; Work/Live (4+ units)3
Minimum unitsNot set TMC 13.06.040E.3
4 units TMC 13.01.060
for Dwelling, multi-unit (4+ units)1
Minimum lot size0 sq ft TMC 13.06.040F.1.c
Minimum lot width0 ft TMC 13.06.040F.1.d
Minimum density40 units per acre TMC 13.06.040F.5.c
  • No limit10 TMC 13.06.040F.5.c
  • 40 units per acre11 TMC 13.06.040F.5.c
for Dwelling, single-unit detached (1 unit)1; Dwelling, townhouse (1 unit)1; Live/Work (1 unit)1; Work/Live (1 unit)3
Not set TMC 13.06.040E.3
for Group housing (group living)1; Special needs housing (group living)1; Permanent shelter (group living)1; Confidential shelter (group living)1; Juvenile community facility (group living)5; Work release center (group living)7; Temporary shelter (group living)9
Maximum residentsNot set TMC 13.06.040E.3
16 persons TMC 13.06.080H.4.a
for Juvenile community facility (group living)5
15 persons TMC 13.06.040E.3; 13.06.040A
for Work release center (group living)7
the smallest of 100, lot area ÷ 150, rounded down persons TMC 13.06.080N.3.d(1); 13.06.080N.3.d(2)
for Temporary shelter (group living)9

3. Building standards

StandardValueExceptions
Front setback
  • 0 ft12 TMC 13.06.040F.1.e
  • 10 ft13 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.040F.1.e
Maximum front setback
  • 20 ft15 TMC 13.06.040H
  • Not set16 TMC 13.06.040H
Side setback
  • 0 ft17 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.040F.1.e
  • 5 ft17 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.040F.1.e
for Dwelling, townhouse (1 unit)1
Rear setback
  • 0 ft17 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.040F.1.e
  • 5 ft17 TMC 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.040F.1.e
for Dwelling, townhouse (1 unit)1
Building separation
  • 6 ft18 TMC 13.06.010H.4.a(2)
  • 10 ft19 TMC 13.06.010H.4.a(2)
  • 10 + (building stories − 6, rounded up) ft20 TMC 13.06.010H.4.a(3)
  • 10 + (2 × (building stories − 6, rounded up)) ft21 TMC 13.06.010H.4.a(3)
Maximum height
  • 75 ft22 TMC 13.06.040F.2.c
  • 100 ft23 TMC 13.06.040G.3
  • 120 ft24 TMC 13.06.040G.3
  • 65 ft25 TMC 13.06.040G.3
  • 85 ft26 TMC 13.06.040G.3
Minimum parking
  • 0 spaces per unit27 TMC 13.06.090C.4.a(4)
  • 0.5 spaces per unit28 TMC 13.06.090C.3.l(2)
  • 1 space per unit29 TMC 13.06.090C.3.l(2)
0 spaces per sleeping unit TMC 13.06.090C.3.l(3)(d)
for Group housing (group living)1
0.7 × ((0.1 × beds in the project) + employees on the largest shift) spaces TMC 13.06.090C.3.l(2); 13.06.090C.3 Table 1
for Special needs housing (group living)1; Permanent shelter (group living)1; Confidential shelter (group living)1; Temporary shelter (group living)9
0.7 × 1.2 × employees on the largest shift spaces TMC 13.06.090C.3.l(2); 13.06.090C.3 Table 1; 13.06.090C.3 Table 2 note 5
for Juvenile community facility (group living)5; Work release center (group living)7

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units TMC 13.06.080A.4.a
Minimum lot sizeNo limit TMC 13.06.080A.5.a

Building

StandardValueExceptions
Front setback
  • 0 ft12 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • 10 ft13 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.080A.5.d; 13.06.040F.1.e
Side setback
  • 0 ft17 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • 5 ft17 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.080A.5.d; 13.06.040F.1.e
for Dwelling, townhouse (1 unit)2
Rear setback
  • 0 ft17 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • 5 ft17 TMC 13.06.080A.5.d; 13.06.040F.1.e
  • equal to the residential zoning district for the first 100 feet from that side14 TMC 13.06.080A.5.d; 13.06.040F.1.e
for Dwelling, townhouse (1 unit)2
Maximum height
  • 75 ft22 TMC 13.06.080A.5.c; 13.06.040F.2.c
  • 100 ft23 TMC 13.06.080A.5.c; 13.06.040G.3
  • 120 ft24 TMC 13.06.080A.5.c; 13.06.040G.3
  • 65 ft25 TMC 13.06.080A.5.c; 13.06.040G.3
  • 85 ft26 TMC 13.06.080A.5.c; 13.06.040G.3
Minimum parking0 spaces per unit TMC 13.06.080A.4.d
Maximum unit size1,000 sq ft TMC 13.06.080A.5.b(1)
Attached to the main houseNot required TMC 13.06.080A.5.a

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision TMC 13.05.070H Table H; 13.04.090A A 2 to 9 TMC 13.05.070H Table H; TMC 13.01.040 —
Minimum lot size
0 sq ft TMC 13.06.040F.1.c
Minimum lot width
0 ft TMC 13.06.040F.1.d
Subdivision TMC 13.05.110B; 13.05.070H Table H H 10 or more TMC 13.01.040 —
Minimum lot size
0 sq ft TMC 13.06.040F.1.c
Minimum lot width
0 ft TMC 13.06.040F.1.d
Binding site plan TMC 13.05.070H Table H; 13.04.088BOnly for: Dwelling, multi-unit A
Minimum lots
Not set TMC 13.04.088
—
Minimum lot size
Not set TMC 13.04.088

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  2. None of these is true:
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  3. None of these is true:
    • The site is in the Commercial-only area of the UCX District
  4. None of these is true:
    • The site is in the Commercial-only area of the UCX District
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  5. All of these are true:
    • The lot line is one-half mile or more from any other juvenile community facility
    None of these is true:
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  6. All of these are true:
    • The lot line is one-half mile or more from any other juvenile community facility
    None of these is true:
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  7. All of these are true:
    • The lot line is at least one-half mile from any other work release facility
    • The lot line is 600 feet or more from any residential zone, RCX zone, day care, church with day care, family day care, crisis care facility, special needs housing, school or public park
  8. All of these are true:
    • The lot line is at least one-half mile from any other work release facility
    • The lot line is 600 feet or more from any residential zone, RCX zone, day care, church with day care, family day care, crisis care facility, special needs housing, school or public park
    None of these is true:
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  9. None of these is true:
    • The site is in a critical area or its buffer
    • The site is within the area indicated in Figure 4, Tacoma Mall Neighborhood RGC – No Residential Uses
  10. All of these are true:
    • The site is currently developed with one single-unit house
    • The project is one infill single-unit house
  11. Not all of these are true:
    • The site is currently developed with one single-unit house
    • The project is one infill single-unit house
  12. None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
    • The X District property is across a non-designated Pedestrian Street from UR-1, UR-2 or UR-3 District property
  13. All of these are true:
    • The X District property is across a non-designated Pedestrian Street from UR-1, UR-2 or UR-3 District property
    None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  14. The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  15. The lot abuts a designated pedestrian street (TMC 13.06.010D)
  16. None of these is true:
    • The lot abuts a designated pedestrian street (TMC 13.06.010D)
  17. None of these is true:
    • The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
  18. All of these are true:
    • Building height is at most 25
    • Building stories is at most 6
  19. All of these are true:
    • Building height is more than 25
    • Building stories is at most 6
  20. All of these are true:
    • Building stories is more than 6
    None of these is true:
    • Another building on the same site, adjacent to this one, also exceeds six stories
  21. All of these are true:
    • Building stories is more than 6
    • Another building on the same site, adjacent to this one, also exceeds six stories
  22. All of these are true:
    • Which UCX height area of TMC 13.06.040J Figure 2 the site is in (75 ft base or 65 ft base) is base_75
    • Which X-District height bonus level the project uses (none, Level 1 or Level 2 palette) is none
  23. All of these are true:
    • Which UCX height area of TMC 13.06.040J Figure 2 the site is in (75 ft base or 65 ft base) is base_75
    • Which X-District height bonus level the project uses (none, Level 1 or Level 2 palette) is level1
  24. All of these are true:
    • Which UCX height area of TMC 13.06.040J Figure 2 the site is in (75 ft base or 65 ft base) is base_75
    • Which X-District height bonus level the project uses (none, Level 1 or Level 2 palette) is level2
  25. All of these are true:
    • Which UCX height area of TMC 13.06.040J Figure 2 the site is in (75 ft base or 65 ft base) is base_65
    • Which X-District height bonus level the project uses (none, Level 1 or Level 2 palette) is one of none, level2
  26. All of these are true:
    • Which UCX height area of TMC 13.06.040J Figure 2 the site is in (75 ft base or 65 ft base) is base_65
    • Which X-District height bonus level the project uses (none, Level 1 or Level 2 palette) is level1
  27. The project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use
  28. All of these are true:
    • The site is in the Tacoma Mall Center
    None of these is true:
    • The project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use
  29. None of these is true:
    • The project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use
    • The site is in the Tacoma Mall Center