NRX · Neighborhood Residential Mixed-Use District
Tacoma, WA · TMC 13.06.040 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, single-unit detached | Home✓ ADU✓ | — | — | — | — |
| Dwelling, townhouse | HomeA ADU✓ | — | — | — | — |
| Live/Work | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Work/Live | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Dwelling, two-unit | — | HomeA ADU✓ | — | — | — |
| Dwelling, three-unit | — | — | HomeA ADU✓ | — | — |
| Retirement home | — | — | — | Home✓ ADU✓ | — |
| Group housing | — | — | — | — | Home✓ ADU✓ |
| Special needs housing | — | — | — | — | |
| Permanent shelter | — | — | — | — | Home✓ ADU✓ |
| Confidential shelter | — | — | — | — | Home✓ ADU✓ |
| Juvenile community facility | — | — | — | — | |
| Temporary shelter | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 20 units TMC 13.06.040E.3 | Not set TMC 13.06.040E.3
for Retirement home (4+ units) |
| Minimum lot size | Not set TMC 13.06.040F.1.c | 3,500 sq ft TMC 13.06.040F.1.c
for Dwelling, single-unit detached (1 unit) 2,500 × main dwelling units on the lot sq ft TMC 13.06.040F.1.c
for Dwelling, two-unit (2 units) 6,000 sq ft TMC 13.06.040F.1.c
for Dwelling, three-unit (3 units) |
| Minimum lot width | Not set TMC 13.06.040F | 25 ft TMC 13.06.040F.1.d
for Dwelling, single-unit detached (1 unit); Dwelling, two-unit (2 units); Dwelling, three-unit (3 units) 14 ft TMC 13.06.040F.1.d
for Dwelling, townhouse (1 unit) |
| Minimum density | No limit TMC 13.06.040F.5.c | Not set TMC 13.06.040E.3; 13.05.070H Table H; 13.06.080H.3
for Juvenile community facility (group living)3 |
| Minimum development size | Not set TMC 13.06.040E.3 | 5,000 sq ft TMC 13.06.040F.1.c
for Dwelling, townhouse (1 unit) |
| Maximum residents | Not set TMC 13.06.040E.3 | 8 persons TMC 13.06.080H.4.a
for Juvenile community facility (group living)3 the smallest of 100, lot area ÷ 150, rounded down persons TMC 13.06.080N.3.d(1); 13.06.080N.3.d(2)
for Temporary shelter (group living)4 |
| Maximum beds | Not set TMC 13.06.040E.3 | 24 beds TMC 13.06.040E.3
for Special needs housing (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Building separation | ||
| Maximum height | 35 ft TMC 13.06.040F.2.c | |
| Minimum parking | 0 spaces per sleeping unit TMC 13.06.090C.3.l(3)(d)
for Group housing (group living) 0.7 × ((0.1 × beds in the project) + employees on the largest shift) spaces TMC 13.06.090C.3.l(2); 13.06.090C.3 Table 1
0.7 × 1.2 × employees on the largest shift spaces TMC 13.06.090C.3.l(2); 13.06.090C.3 Table 1; 13.06.090C.3 Table 2 note 5
for Juvenile community facility (group living)3 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units TMC 13.06.080A.4.a | |
| Minimum lot size | No limit TMC 13.06.080A.5.a |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft TMC 13.06.080A.5.c; 13.06.040F.2.c | |
| Minimum parking | 0 spaces per unit TMC 13.06.080A.4.d | |
| Maximum unit size | 1,000 sq ft TMC 13.06.080A.5.b(1) | |
| Attached to the main house | Not required TMC 13.06.080A.5.a |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TMC 13.05.070H Table H; 13.04.090A | A | 2 to 9 TMC 13.05.070H Table H; TMC 13.01.040 | ||
| Subdivision TMC 13.05.110B; 13.05.070H Table H | H | 10 or more TMC 13.01.040 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Beds in the project is at most 24
- Beds in the project is more than 24
- The lot line is one-half mile or more from any other juvenile community facility
- None of these is true:
- The site is in a critical area or its buffer
- None of these is true:
- The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
- The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
- All of these are true:
- Building height is at most 25
- Building stories is at most 6
- All of these are true:
- Building height is more than 25
- Building stories is at most 6
- All of these are true:
- Building stories is more than 6
- Another building on the same site, adjacent to this one, also exceeds six stories
- All of these are true:
- Building stories is more than 6
- Another building on the same site, adjacent to this one, also exceeds six stories
- The project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use
- It is not true that the project is mixed-use with at least 50 percent of the floor area designed for commercial or institutional use
- The new lots are for townhouse dwellings
- None of these is true:
- The new lots are for townhouse dwellings