M1 · Light Industrial District
Tacoma, WA · TMC 13.06.060 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Live/Work | — | ||||
| Work/Live | — | ||||
| Multiplex | — | — | — | — | |
| Retirement home | — | — | — | — | |
| Group housing | — | — | — | — | |
| Special needs housing | — | — | — | — | |
| Permanent shelter | — | — | — | — | |
| Confidential shelter | — | — | — | — | |
| Temporary shelter | — | — | — | — | |
| Juvenile community facility | — | — | — | — | |
| Work release center | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set TMC 13.06.060E.5 | 20 units TMC 13.06.060E.5
for Live/Work (4+ units); Work/Live (4+ units) |
| Minimum units | Not set TMC 13.06.060E.5 | 7 units TMC 13.01.060
for Multiplex (4+ units)2 |
| Maximum residents | Not set TMC 13.06.060E.5 | the smallest of 100, lot area ÷ 150, rounded down persons TMC 13.06.080N.3.d(1); 13.06.080N.3.d(2)
16 persons TMC 13.06.080H.4.a
for Juvenile community facility (group living)8 25 persons TMC 13.06.080R.3.a
for Work release center (group living)10 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 0 ft TMC 13.06.060F.5 | |
| Rear setback | 0 ft TMC 13.06.060F.6 | |
| Building separation | ||
| Maximum height | 75 ft TMC 13.06.060F.7 | |
| Maximum lot coverage | 75% TMC 13.06.060F.3 | |
| Minimum parking | 1.25 spaces per unit TMC 13.06.090C.3 Table 1
0.75 spaces per sleeping unit TMC 13.06.090C.3 Table 1
for Group housing (group living)4 (0.1 × beds in the project) + employees on the largest shift spaces TMC 13.06.090C.3 Table 1
| |
| Minimum open space | Not set TMC 13.06.060E.5 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units TMC 13.06.080A.4.a | |
| Minimum lot size | No limit TMC 13.06.080A.5.a |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 0 ft TMC 13.06.080A.5.d; 13.06.060F.5 | |
| Rear setback | 0 ft TMC 13.06.080A.5.d; 13.06.060F.6 | |
| Maximum height | 75 ft TMC 13.06.080A.5.c; 13.06.060F.7 | |
| Minimum parking | 0 spaces per unit TMC 13.06.080A.4.d | |
| Maximum unit size | 1,000 sq ft TMC 13.06.080A.5.b(1) | |
| Attached to the main house | Not required TMC 13.06.080A.5.a |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision TMC 13.05.070H Table H; 13.04.090A | A | 2 to 9 TMC 13.05.070H Table H; TMC 13.01.040 | — | Minimum lot size Not set TMC 13.06.060F.1 |
| Subdivision TMC 13.05.110B; 13.05.070H Table H | H | 10 or more TMC 13.01.040 | — | Minimum lot size Not set TMC 13.06.060F.1 |
| Binding site plan TMC 13.05.070H Table H; 13.04.088B | A | Minimum lots Not set TMC 13.04.088 |
— | Minimum lot size Not set TMC 13.04.088 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The site is within the South Tacoma M/IC Overlay District
- The dwellings are within a mixed-use building where at least 1/3 of the building is devoted to industrial or commercial use
- All of these are true:
- The dwellings are within a mixed-use building where at least 1/3 of the building is devoted to industrial or commercial use
- The site is within the South Tacoma M/IC Overlay District
- All of these are true:
- Any of these is true:
- The use is within a residential or institutional building in existence on December 31, 2008
- The dwellings are within a mixed-use building where at least 1/3 of the building is devoted to industrial or commercial use
- The site is within the South Tacoma M/IC Overlay District
- Any of these is true:
- All of these are true:
- Any of these is true:
- The use is within a residential or institutional building in existence on December 31, 2008
- The dwellings are within a mixed-use building where at least 1/3 of the building is devoted to industrial or commercial use
- The site is within the South Tacoma M/IC Overlay District
- The site is within the South Tacoma M/IC Overlay District
- Any of these is true:
- None of these is true:
- The site is within the South Tacoma M/IC Overlay District
- The site is within the South Tacoma M/IC Overlay District
- The site is within the South Tacoma M/IC Overlay District
- All of these are true:
- The lot line is one-half mile or more from any other juvenile community facility
- The site is within the South Tacoma M/IC Overlay District
- All of these are true:
- The lot line is one-half mile or more from any other juvenile community facility
- The site is within the South Tacoma M/IC Overlay District
- The site is within the South Tacoma M/IC Overlay District
- All of these are true:
- The lot line is at least one-half mile from any other work release facility
- The lot line is 600 feet or more from any residential zone, RCX zone, day care, church with day care, family day care, crisis care facility, special needs housing, school or public park
- All of these are true:
- The lot line is at least one-half mile from any other work release facility
- The lot line is 600 feet or more from any residential zone, RCX zone, day care, church with day care, family day care, crisis care facility, special needs housing, school or public park
- The site is within the South Tacoma M/IC Overlay District
- None of these is true:
- The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
- The lot abuts a residentially zoned property (the setback applies for the first 100 feet from that side)
- All of these are true:
- Building height is at most 25
- Building stories is at most 6
- All of these are true:
- Building height is more than 25
- Building stories is at most 6
- All of these are true:
- Building stories is more than 6
- Another building on the same site, adjacent to this one, also exceeds six stories
- All of these are true:
- Building stories is more than 6
- Another building on the same site, adjacent to this one, also exceeds six stories
- The live/work or work/live units are within a building lawfully in existence prior to December 5, 1989
- None of these is true:
- The live/work or work/live units are within a building lawfully in existence prior to December 5, 1989