R-3 · High Density Residential
Sunnyside, WA · SMC 17.20 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, one-family | Home✓ ADU✓ | — | — | — | — |
| Zero lot line development | Home✓ ADU— | — | — | — | — |
| Dwelling, two-family | — | Home✓ ADU— | — | — | — |
| Dwelling, multiple | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Apartment house | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Mobile home court, park or camp | — | — | — | — | |
| Group residential facility | — | — | — | — | HomeH ADU— |
| Convalescent, nursing, retirement homes | — | — | — | — | HomeH ADU— |
| Charitable institutions and orphanages | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,300 sq ft SMC 17.20.030(A) | |
| Minimum lot width | 50 ft SMC 17.20.030(B) | |
| Minimum density | 1 units per acre SMC 17.20.010 | Not set SMC 16.12.130
for Mobile home court, park or camp (4+ units)1; Group residential facility (group living); Convalescent, nursing, retirement homes (group living); Charitable institutions and orphanages (group living) |
| Maximum density | No limit SMC 17.20.010 | for Mobile home court, park or camp (4+ units)1 Not set SMC 17.20.030
for Group residential facility (group living); Convalescent, nursing, retirement homes (group living); Charitable institutions and orphanages (group living) |
| Minimum development size | Not set SMC 17.20.030 | 130,680 sq ft SMC 17.64.020(U); 16.12.100
for Mobile home court, park or camp (4+ units)1 |
| Maximum residents | Not set SMC 17.64.020(B) | 8 persons SMC 17.04.030
for Group residential facility (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft SMC 17.20.040(A) | |
| Side setback | 5 ft SMC 17.20.040(B) | |
| Street side setback | 20 ft SMC 17.20.040(B) | |
| Rear setback | 15 ft SMC 17.20.040(C) | 5 ft SMC 16.12.120(A)-(B)
for Mobile home court, park or camp (4+ units)1 |
| Building separation | Not set SMC 17.20.040 | 10 ft SMC 16.12.120(B)
for Mobile home court, park or camp (4+ units)1 |
| Maximum height | 35 ft SMC 17.20.030(C) | |
| Maximum stories | 3 stories SMC 17.20.030(C) | |
| Maximum lot coverage | 75% SMC 17.20.030(D) | |
| Minimum parking | 2 spaces per unit SMC 17.64.040(T) | 1 space per unit SMC 17.64.040(A)
for Dwelling, multiple (4+ units); Apartment house (4+ units) for Mobile home court, park or camp (4+ units)1 Parking requirements for any specific occupancy or use not listed in this section will be determined in accordance with the use most closely related to such proposed use as determined by City staff. SMC 17.64.040
for Group residential facility (group living); Charitable institutions and orphanages (group living) the largest of 2, (beds in the project ÷ 5) + (employees on the largest shift ÷ 2) spaces SMC 17.64.040(E)
for Convalescent, nursing, retirement homes (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit SMC 17.64.015(B)(6) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft SMC 17.20.030(C) | |
| Maximum stories | 3 stories SMC 17.20.030(C) | |
| Minimum parking | 1 space per unit SMC 17.64.040(V); 17.64.015(B)(2) | |
| Maximum unit size | 1,000 sq ft SMC 17.64.015(B)(3) | |
| Attached to the main house | Not required SMC 17.64.015(B)(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 16.04.030(A); 16.04.090 | A | up to 9 SMC 16.24.300; 16.04.010(K) | — | Minimum lot size 4,300 sq ft SMC 17.20.030(A) Minimum lot width 50 ft SMC 17.20.030(B) Minimum lot depth Not set SMC 16.32.040 Maximum units per lot Not set SMC 16.32 |
| Subdivision SMC 16.28.070; 16.28.110; 16.28.120 | H | 10 or more SMC 16.24.330; 16.24.300 | — | Minimum lot size 4,300 sq ft SMC 17.20.030(A) Minimum lot width 50 ft SMC 17.20.030(B) Minimum lot depth Not set SMC 16.32.040 Maximum units per lot Not set SMC 16.32 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- Access to the use is only from a collector or arterial street
- Any of these is true:
- Lot area is at most 435,600 sf
- The mobile home park has access on a street designated by the City as a collector or arterial street
- Density increase the Commission grants a mobile home park: none; 10% for dedicated open space of 50% or more; plus 5% for a maintained playground; plus 10% for a recreation/community building is none
- Density increase the Commission grants a mobile home park: none; 10% for dedicated open space of 50% or more; plus 5% for a maintained playground; plus 10% for a recreation/community building is open_space
- Density increase the Commission grants a mobile home park: none; 10% for dedicated open space of 50% or more; plus 5% for a maintained playground; plus 10% for a recreation/community building is open_space_playground
- Density increase the Commission grants a mobile home park: none; 10% for dedicated open space of 50% or more; plus 5% for a maintained playground; plus 10% for a recreation/community building is open_space_playground_building
- The lot line is the line of a lot not approved for zero lot line development
- All of these are true:
- The side lot line is the zero lot line shown on the plat
- The lot line is the line of a lot not approved for zero lot line development
- None of these is true:
- The lot line is the line of a lot not approved for zero lot line development
- The side lot line is the zero lot line shown on the plat
- Streets within the mobile home park are improved to 40 feet in width
- None of these is true:
- Streets within the mobile home park are improved to 40 feet in width
- None of these is true:
- The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
- The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
- The lot is within the arc of a curve or has unusual topography
- None of these is true:
- The lot is within the arc of a curve or has unusual topography