Sign in

R-2 · Medium Density Residential

Sunnyside, WA · SMC 17.16 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, one-family
Home✓ ADU✓
————
Zero lot line development
Home✓ ADU—
————
Manufactured home
HomeH1 ADU✓1
————
Dwelling, two-family—
Home✓ ADU—
———
Dwelling, multiple——
Home✓ ADU—
Home✓ ADU—
—
Apartment house——
Home✓ ADU—
Home✓ ADU—
—
Group residential facility————
HomeH ADU—
Convalescent, nursing, retirement homes————
HomeH ADU—
Charitable institutions and orphanages————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size4,300 sq ft SMC 17.16.030(A)
Minimum lot width50 ft SMC 17.16.030(B)
Minimum density1 units per acre SMC 17.16.010
Not set SMC 17.16.030
for Group residential facility (group living); Convalescent, nursing, retirement homes (group living); Charitable institutions and orphanages (group living)
Maximum density9 units per acre SMC 17.16.010
16 units per acre SMC 17.16.010
for Dwelling, multiple (3, 4+ units); Apartment house (3, 4+ units)
Not set SMC 17.16.030
for Group residential facility (group living); Convalescent, nursing, retirement homes (group living); Charitable institutions and orphanages (group living)
Maximum residentsNot set SMC 17.64.020(B)
8 persons SMC 17.04.030
for Group residential facility (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft SMC 17.16.040(A)
Side setback5 ft SMC 17.16.040(B)
  • 10 ft2 SMC 17.16.070(C)(4)
  • 0 ft3 SMC 17.16.070(C)(1)
  • 5 ft4 SMC 17.16.040(B)
for Zero lot line development (1 unit)
Street side setback20 ft SMC 17.16.040(B)
Rear setback15 ft SMC 17.16.040(C)
Maximum height35 ft SMC 17.16.030(C)
Maximum stories2 stories SMC 17.16.030(C)
Maximum lot coverage55% SMC 17.16.030(D)
Minimum parking2 spaces per unit SMC 17.64.040(T)
1 space per unit SMC 17.64.040(A)
for Dwelling, multiple (4+ units); Apartment house (4+ units)
Parking requirements for any specific occupancy or use not listed in this section will be determined in accordance with the use most closely related to such proposed use as determined by City staff. SMC 17.64.040
for Group residential facility (group living); Charitable institutions and orphanages (group living)
the largest of 2, (beds in the project ÷ 5) + (employees on the largest shift ÷ 2) spaces SMC 17.64.040(E)
for Convalescent, nursing, retirement homes (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit SMC 17.64.015(B)(6)

Building

StandardValueExceptions
Front setback
  • 20 ft5 SMC 17.16.040(A)
  • 20 ft6 SMC 17.16.040(D)
Side setback
  • 5 ft5 SMC 17.16.040(B)
  • 5 ft6 SMC 17.16.040(D)
Rear setback
  • 15 ft5 SMC 17.16.040(C)
  • 5 ft6 SMC 17.16.040(D)
Maximum height35 ft SMC 17.16.030(C)
Maximum stories2 stories SMC 17.16.030(C)
Minimum parking1 space per unit SMC 17.64.040(V); 17.64.015(B)(2)
Maximum unit size1,000 sq ft SMC 17.64.015(B)(3)
Attached to the main houseNot required SMC 17.64.015(B)(1)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 16.04.030(A); 16.04.090 A up to 9 SMC 16.24.300; 16.04.010(K) —
Minimum lot size
4,300 sq ft SMC 17.16.030(A)
Minimum lot width
50 ft SMC 17.16.030(B)
Minimum lot depth
Not set SMC 16.32.040
Minimum frontage
  • 40 ft7 SMC 16.32.040(B)
  • 50 ft8 SMC 16.32.040(B); 17.16.030(B)
Maximum units per lot
Not set SMC 16.32
Subdivision SMC 16.28.070; 16.28.110; 16.28.120 H 10 or more SMC 16.24.330; 16.24.300 —
Minimum lot size
4,300 sq ft SMC 17.16.030(A)
Minimum lot width
50 ft SMC 17.16.030(B)
Minimum lot depth
Not set SMC 16.32.040
Minimum frontage
  • 40 ft7 SMC 16.32.040(B)
  • 50 ft8 SMC 16.32.040(B); 17.16.030(B)
Maximum units per lot
Not set SMC 16.32

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The manufactured home is placed permanently on a lot with a foundation built to conventional construction requirements
    • The manufactured home is designated as real property and taxed as real property
    • Floor area of the main house is at least 950
    • The manufactured home is built to federal manufactured home construction and safety standards, with an affixed certification label (24 CFR 3280.8)
    • The manufactured home meets any other requirements to be eligible for FHA mortgage insurance (Title II)
    • The manufactured home is new or not previously occupied
  2. The lot line is the line of a lot not approved for zero lot line development
  3. All of these are true:
    • The side lot line is the zero lot line shown on the plat
    None of these is true:
    • The lot line is the line of a lot not approved for zero lot line development
  4. None of these is true:
    • The lot line is the line of a lot not approved for zero lot line development
    • The side lot line is the zero lot line shown on the plat
  5. None of these is true:
    • The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
  6. The ADU is attached to or built above a detached garage, or is a stand-alone structure (not attached to the primary structure)
  7. The lot is within the arc of a curve or has unusual topography
  8. None of these is true:
    • The lot is within the arc of a curve or has unusual topography