Residential Protection · Residential-protection district (RP)
Sumner, WA · SMC 18.10 · Official code
By right: 1 unit · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | Home✓ ADU✓ | — | — | — | — |
| Manufactured home | — | — | — | — | |
| Retirement home | — | — | — | HomeH ADU— | — |
| Continuing care or life care communities | — | — | — | HomeH ADU— | — |
| Residential structures for agricultural employees of the occupant of the main or principal structure | — | — | — | HomeH ADU— | — |
| Group home, small | — | — | — | — | Home✓ ADU— |
| Assisted living facilities | — | — | — | — | HomeH ADU— |
| Board and care homes | — | — | — | — | HomeH ADU— |
| Hospice | — | — | — | — | HomeH ADU— |
| Nursing home, convalescent home | — | — | — | — | HomeH ADU— |
| Permanent supportive housing | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set SMC 18.10.070 | the number of units in residential structures for agricultural employees shall be limited to the maximum number of employees SMC 18.10.040(O)
for Residential structures for agricultural employees of the occupant of the main or principal structure (4+ units) |
| Minimum lot size | 871,200 sq ft SMC 18.10.070(A) | |
| Minimum lot width | 150 ft SMC 18.10.070(C) | |
| Minimum frontage | 60 ft SMC 18.10.070(K) | |
| Maximum density | 1 ÷ 20 units per acre SMC 18.10.070(B) | |
| Maximum residents | Not set SMC 18.10.070 | 8 persons SMC 18.04.0455
for Group home, small (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 35 ft SMC 18.10.070(D) | |
| Side setback | 10 ft SMC 18.10.070(F) | |
| Street side setback | 15 ft SMC 18.10.070(G) | |
| Rear setback | 40 ft SMC 18.10.070(E) | |
| Maximum height | 35 ft SMC 18.10.070(H) | |
| Maximum lot coverage | 25% SMC 18.10.070(I) | |
| Minimum parking | In the case of a use not specifically mentioned in this chapter the requirements for off-street parking facilities shall be determined by the director. SMC 18.42.090 | 2 spaces per unit SMC 18.10.070(J)
main dwelling units on the lot + (main dwelling units on the lot ÷ 7) + employees on the largest shift spaces SMC 18.42.040(B)(2)
for Retirement home (4+ units) (beds in the project ÷ 6) + employees on the largest shift spaces SMC 18.42.040(E)
for Nursing home, convalescent home (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 18.12.030(A)(1) | |
| Minimum lot size | 871,200 sq ft SMC 18.12.030(A)(1); 18.10.070(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Front yard setback: equal to or greater than existing front setback of the primary dwelling unit SMC 18.12.030(A)(8)(a) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 24 ft SMC 18.12.030(A)(7) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft SMC 18.12.030(A)(3) | |
| Attached to the main house | Not required SMC 18.12.030(A)(5) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Lot line adjustment SMC 17.08.040(C); 18.56.030(B)(3) | ✓ | Maximum lots the relocation does not result in the creation of any additional lot or lots SMC 17.04.060 |
— | Minimum lot size 871,200 sq ft SMC 18.10.070(A) Minimum lot width 150 ft SMC 18.10.070(C) Minimum frontage 60 ft SMC 18.10.070(K) |
| Subdivision, short SMC 18.56.030(D)(1); 18.56.030(G)(4) | A | up to 9 SMC 17.04.040(A); 17.12.030 | — | Minimum lot size 871,200 sq ft SMC 18.10.070(A) Minimum lot width 150 ft SMC 18.10.070(C) Minimum frontage 60 ft SMC 18.10.070(K) |
| Subdivision, full SMC 18.56.030(I)(3); 17.16.040(A) | H | 10 or more SMC 17.04.040(A) | — | Minimum lot size 871,200 sq ft SMC 18.10.070(A) Minimum lot width 150 ft SMC 18.10.070(C) Minimum frontage 60 ft SMC 18.10.070(K) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Manufactured home is new
- ADU is 18 feet or less in height
- None of these is true:
- ADU is 18 feet or less in height
- Rear property line abuts an alley
- All of these are true:
- ADU is 18 feet or less in height
- Rear property line abuts an alley
- None of these is true:
- Rear property line abuts an alley
- ADU is 18 feet or less in height
- None of these is true:
- ADU is within one-half mile of the Sumner transit station
- ADU is within one-half mile of the Sumner transit station