Neighborhood Commercial · Neighborhood Commercial (NC) Zone
Sultan, WA · SMC 16.12.040 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached dwellings | Home✓ ADU✓ | — | — | — | — |
| Manufactured homes | Home✓ ADU✓ | — | — | — | — |
| Apartments accessory to commercial uses | — | — | — | — | |
| Duplexes/two-family dwellings | — | Home✓ ADU✓ | — | — | — |
| Townhouses | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Cottage housing | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Apartments/multifamily dwellings | — | — | — | Home✓ ADU✓ | — |
| Group homes | — | — | — | — | Home✓ ADU✓ |
| Boarding houses | — | — | — | — | Home✓ ADU✓ |
| Residential care facilities | — | — | — | — | Home✓ ADU✓ |
| Co-living housing | — | — | — | — | Home✓ ADU✓ |
| Transitional housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set SMC 16.12.040(E); 16.36.090(A) | 5 units SMC 16.04.040.29
|
| Minimum lot size | 2,000 × main dwelling units on the lot sq ft SMC 16.12.040(E); 16.36.090(A) | for Single-family detached dwellings (1 unit); Manufactured homes (1 unit); Group homes (group living) Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 1,500 × main dwelling units on the lot sq ft SMC 16.12.040(E); 16.36.200(A)
for Cottage housing (2, 3, 4+ units) 8,000 + (1,000 × (the largest of main dwelling units on the lot − 4, 0)) sq ft SMC 16.12.040(E); 16.36.120(A)
No limit SMC 16.36.030(A)
for Apartments/multifamily dwellings (4+ units)5 for Boarding houses (group living); Residential care facilities (group living) 8,000 + (250 × (the largest of sleeping units in the project − 24, 0)) sq ft SMC 16.12.040(E)
for Co-living housing (group living) |
| Minimum lot width | Not set SMC 16.12.040(E); 16.36.060(A) | |
| Minimum frontage | 20 ft SMC 16.04.010.3 | |
| Maximum density | 24 units per acre SMC 16.12.040(B) | No limit SMC 16.12.040(B)
for Cottage housing (2, 3, 4+ units); Apartments/multifamily dwellings (4+ units)5; Co-living housing (group living) |
| Maximum residents | Not set SMC 16.12.040(E); 16.36.060(A) | 20 persons SMC 16.04.020.18
for Boarding houses (group living) |
| Maximum sleeping units | Not set SMC 16.12.040(E); 16.36.060(A) | 10 sleeping units SMC 16.12.040(F)(6)
for Boarding houses (group living); Residential care facilities (group living) No limit SMC 16.12.040(B)
for Co-living housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 0 ft SMC 16.36.030(E)
for Apartments/multifamily dwellings (4+ units)5 for Boarding houses (group living); Residential care facilities (group living) | |
| Maximum front setback | Not set SMC 16.12.040(E); 16.36.060(A) | 10 ft SMC 16.36.030(E)
for Apartments/multifamily dwellings (4+ units)5 |
| Side setback | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 0 ft SMC 16.36.030(E)
for Apartments/multifamily dwellings (4+ units)5 | |
| Street side setback | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 0 ft SMC 16.36.030(E); 16.12.005(D)(2)
for Apartments/multifamily dwellings (4+ units)5 | |
| Rear setback | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 | |
| Building separation | Not set SMC 16.12.040(E); 16.36.060(A) | 10 ft SMC 16.36.200(A)
for Cottage housing (2, 3, 4+ units) |
| Maximum height | 30 ft SMC 16.12.040(E); 16.36.060(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 24 ft SMC 16.12.040(E)
for Cottage housing (2, 3, 4+ units) |
| Maximum stories | Not set SMC 16.12.040(E); 16.36.060(A) | |
| Maximum lot coverage | 60% SMC 16.12.040(E); 16.36.060(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 50% SMC 16.12.040(E); 16.36.200(A)
for Cottage housing (2, 3, 4+ units) 65% SMC 16.36.030(E)
for Apartments/multifamily dwellings (4+ units)5 |
| Minimum parking | 1 space per unit SMC 16.54.140
for Cottage housing (2, 3, 4+ units) 2 spaces per unit SMC 16.54.140
for Group homes (group living) 1 × bedrooms in the whole project spaces SMC 16.54.140
for Boarding houses (group living) 1 space per bed SMC 16.54.140
for Residential care facilities (group living) 0.25 spaces per sleeping unit SMC 16.54.140
for Co-living housing (group living) 1.25 × employees on the largest shift spaces SMC 16.54.140; 16.68.010(C)(3)(a)-(c)
| |
| Maximum building floor area | Not set SMC 16.12.040(E); 16.36.060(A) | |
| Maximum building footprint | Not set SMC 16.12.040(E); 16.36.060(A) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 16.12.005(F)(1)(a)-(b); 16.36.150 | 1 unit SMC 16.12.005(F)(1)(a)-(b); 16.36.150
for Duplexes/two-family dwellings (2 units) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Front yard setbacks for accessory dwelling units are 10 feet behind the primary structure unless a conversion of existing structure or a vertical addition to an existing garage that does not add to the existing footprint of the primary unit or its garage. SMC 16.12.005(F)(1)(d); 16.36.160(A) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 24 ft SMC 16.36.160(A); 16.12.040(E) | |
| Minimum parking | 1 space per unit SMC 16.54.140 | |
| Maximum unit size | 1,000 sq ft SMC 16.12.005(F)(1)(c); 16.36.160(A) | |
| Attached to the main house | Not required SMC 16.36.150 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 19.12.050; 19.24.020(B) | A | up to 9 SMC 19.12.010; 19.04.020(A)(44) | — | Minimum lot size Not set SMC 19.14.050(A) Minimum lot width Not set SMC 19.14.050(A) Minimum frontage 20 ft SMC 16.04.010.3 |
| Subdivision SMC 19.06.060(A); 19.08.030; 19.26.020 | H | 10 or more SMC 19.06.020; 19.04.020(A)(49) | — | Minimum lot size Not set SMC 19.08.080(A)(2) Minimum lot width Not set SMC 19.08.080(A)(2) Minimum frontage 20 ft SMC 16.04.010.3 |
| Unit lot subdivision SMC 19.12.010; 19.14.110(A)(2); 19.24.020(B)Only for: Single-family detached dwellings, Manufactured homes, Duplexes/two-family dwellings, Townhouses, Cottage housing, Apartments/multifamily dwellings | A | 2 to 9 SMC 19.04.020(A)(51); SMC 19.14.110(A)(3) | — | Minimum lot size A unit lot may be as small as the footprint of the structure it contains, provided it meets applicable building, fire, and utility code requirements. SMC 19.14.110(B)(5) Minimum lot width Not set SMC 19.14.110(B) Minimum frontage Not set SMC 19.14.110(B)(3) |
| Binding site plan, small-scale SMC 19.18.020; 19.18.040; 19.24.020(A) | A | 2 to 9 SMC 19.18.010; SMC 19.04.020(A)(6) | — | Minimum lot size Not set SMC 19.18.110; 19.18.020 Minimum lot width Not set SMC 19.18.110; 19.18.020 Minimum frontage Not set SMC 19.18.110; 19.18.020 |
| Binding site plan, large-scale SMC 19.18.020; 19.18.050 | H | 10 or more SMC 19.04.020(A)(7) | — | Minimum lot size Not set SMC 19.18.110; 19.18.020 Minimum lot width Not set SMC 19.18.110; 19.18.020 Minimum frontage Not set SMC 19.18.110; 19.18.020 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The residential space has a significant, physical connection to the commercial building it is accessory to
- The apartment connects to public water and sewer service
- It is the only accessory apartment for an established business on the site (one apartment per established business, so long as the site does not exceed the maximum density)
- The building is approved by the building official as a legal, permanent structure
- The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is detached
- The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is attached
- The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is stacked
- All of these are true:
- The developer uses the SMC 16.36 Article I form-based standards for mixed-use development in lieu of the use-based standards
- The building(s) contain a residential use and at least one other use permitted in the zone
- At least 40% of the floor area on the ground floor is dedicated and designed for non-residential uses
- None of these is true:
- The lot is an existing lot, not a lot created by a new division
- The lot is an existing lot, not a lot created by a new division
- None of these is true:
- The lot has a driveway
- The lot has a driveway
- Building height is at most 10
- All of these are true:
- Building height is more than 10
- Building height is at most 20
- Building height is more than 20
- The rear lot line abuts an alley
- None of these is true:
- The rear lot line abuts an alley
- None of these is true:
- The building has a pitched roof
- The building has a pitched roof
- The cottage is built to the Type A (1.5 stories, 800 sq ft footprint) or Type B (2 stories, 1,400 sq ft floor area) standards is type_a
- The cottage is built to the Type A (1.5 stories, 800 sq ft footprint) or Type B (2 stories, 1,400 sq ft floor area) standards is type_b
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is more than 1