Highway Oriented Commercial · Highway-Oriented Commercial (HOC) Zone
Sultan, WA · SMC 16.12.060 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Apartments accessory to commercial uses | — | — | — | — | |
| Townhouses | — | — | |||
| Live/work dwelling units | — | — | |||
| Apartments/multifamily dwellings | — | — | — | — | |
| Co-living housing | — | — | — | — | |
| Emergency shelters | — | — | — | — | Home✓ ADU— |
| Emergency housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set SMC 16.12.060(F); 16.36.090(A) | |
| Minimum lot size | 1,500 × main dwelling units on the lot sq ft SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 8,000 + (1,000 × (the largest of main dwelling units on the lot − 6, 0)) sq ft SMC 16.12.060(F); 16.36.120(A)
No limit SMC 16.36.030(A)
for Apartments/multifamily dwellings (4+ units)4 |
| Minimum lot width | Not set SMC 16.20.100(B) | |
| Minimum frontage | 20 ft SMC 16.04.010.3 | |
| Maximum density | 36 units per acre SMC 16.20.100(B)(3); 16.12.060(B) | |
| Maximum beds | Not set SMC 16.12.060(F) | 40 beds SMC 16.12.060(G)(3)
for Emergency shelters (group living); Emergency housing (group living) |
| Maximum sleeping units | Not set SMC 16.12.060(F); 16.36.090(A) | No limit SMC 16.12.060(B)
for Co-living housing (group living)3 40 sleeping units SMC 16.12.060(G)(3)
for Emergency shelters (group living); Emergency housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 100 ft SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 25 ft SMC 16.12.060(F); 16.36.120(A)
|
| Maximum front setback | Not set SMC 16.20.100(B) | 35 ft SMC 16.36.030(E)
for Apartments/multifamily dwellings (4+ units)4 |
| Side setback | 10 ft SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 3 ft SMC 16.36.030(E)
for Apartments/multifamily dwellings (4+ units)4 |
| Street side setback | 50 ft SMC 16.12.005(D)(2)(a); 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 12.5 ft SMC 16.12.005(D)(2)(a); 16.12.060(F); 16.36.120(A)
25 ft SMC 16.36.030(E); 16.12.005(D)(2)
for Apartments/multifamily dwellings (4+ units)4 |
| Rear setback | 15 ft SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 |
| Maximum height | 35 ft SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 45 ft SMC 16.36.120(A)
|
| Maximum stories | 3 stories SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 4 stories SMC 16.36.120(A)
|
| Maximum lot coverage | 85% SMC 16.12.060(F); 16.36.090(A) | Not set SMC 16.20.100(B)
for Apartments accessory to commercial uses (1 unit)1 |
| Minimum parking | 1.25 spaces per unit SMC 16.54.140
for Live/work dwelling units (2, 3, 4+ units)2 0.25 spaces per sleeping unit SMC 16.54.140
for Co-living housing (group living)3 0 spaces per bed SMC 16.54.140; 16.68.020(C)(4)(a)-(c)
for Emergency shelters (group living); Emergency housing (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 16.12.005(F)(1)(a)-(b); 16.36.150 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Front yard setbacks for accessory dwelling units are 10 feet behind the primary structure unless a conversion of existing structure or a vertical addition to an existing garage that does not add to the existing footprint of the primary unit or its garage. SMC 16.12.005(F)(1)(d); 16.36.160(A) | |
| Side setback | 10 ft SMC 16.20.100(A); 16.12.060(F) | |
| Rear setback | 15 ft SMC 16.20.100(A); 16.12.060(F) | |
| Maximum height | 24 ft SMC 16.36.160(A); 16.12.060(F) | |
| Minimum parking | 1 space per unit SMC 16.54.140 | |
| Maximum unit size | 1,000 sq ft SMC 16.12.005(F)(1)(c); 16.36.160(A) | |
| Attached to the main house | Not required SMC 16.36.150 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 19.12.050; 19.24.020(B) | A | up to 9 SMC 19.12.010; 19.04.020(A)(44) | — | Minimum lot size Not set SMC 19.14.050(A) Minimum lot width Not set SMC 19.14.050(A) Minimum frontage 20 ft SMC 16.04.010.3 |
| Subdivision SMC 19.06.060(A); 19.08.030; 19.26.020 | H | 10 or more SMC 19.06.020; 19.04.020(A)(49) | — | Minimum lot size Not set SMC 19.08.080(A)(2) Minimum lot width Not set SMC 19.08.080(A)(2) Minimum frontage 20 ft SMC 16.04.010.3 |
| Unit lot subdivision SMC 19.12.010; 19.14.110(A)(2); 19.24.020(B)Only for: Townhouses, Apartments/multifamily dwellings | A | 2 to 9 SMC 19.04.020(A)(51); SMC 19.14.110(A)(3) | — | Minimum lot size A unit lot may be as small as the footprint of the structure it contains, provided it meets applicable building, fire, and utility code requirements. SMC 19.14.110(B)(5) Minimum lot width Not set SMC 19.14.110(B) Minimum frontage Not set SMC 19.14.110(B)(3) |
| Binding site plan, small-scale SMC 19.18.020; 19.18.040; 19.24.020(A) | A | 2 to 9 SMC 19.18.010; SMC 19.04.020(A)(6) | — | Minimum lot size Not set SMC 19.18.110; 19.18.020 Minimum lot width Not set SMC 19.18.110; 19.18.020 Minimum frontage Not set SMC 19.18.110; 19.18.020 |
| Binding site plan, large-scale SMC 19.18.020; 19.18.050 | H | 10 or more SMC 19.04.020(A)(7) | — | Minimum lot size Not set SMC 19.18.110; 19.18.020 Minimum lot width Not set SMC 19.18.110; 19.18.020 Minimum frontage Not set SMC 19.18.110; 19.18.020 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The residential space has a significant, physical connection to the commercial building it is accessory to
- The apartment connects to public water and sewer service
- It is the only accessory apartment for an established business on the site (one apartment per established business, so long as the site does not exceed the maximum density)
- The building is approved by the building official as a legal, permanent structure
- Any of these is true:
- All of these are true:
- Any of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- The residential units are part of a stacked, mixed-use building
- The residential units occupy no more than 30% of the ground floor area
- Any of these is true:
- All of these are true:
- Any of these is true:
- None of these is true:
- The lot abuts US-2
- The residential use is developed as part of a mixed-use development with at least 3,000 square feet of commercial space adjacent to US-2
- None of these is true:
- None of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- Any of these is true:
- All of these are true:
- All of these are true:
- Any of these is true:
- None of these is true:
- The lot abuts US-2
- The residential use is developed as part of a mixed-use development with at least 3,000 square feet of commercial space adjacent to US-2
- None of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- Any of these is true:
- Any of these is true:
- All of these are true:
- Any of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- The residential units are part of a stacked, mixed-use building
- The residential units occupy no more than 30% of the ground floor area
- Any of these is true:
- All of these are true:
- Any of these is true:
- None of these is true:
- The lot abuts US-2
- The residential use is developed as part of a mixed-use development with at least 3,000 square feet of commercial space adjacent to US-2
- None of these is true:
- None of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- Any of these is true:
- All of these are true:
- All of these are true:
- The developer uses the SMC 16.36 Article I form-based standards for mixed-use development in lieu of the use-based standards
- The building(s) contain a residential use and at least one other use permitted in the zone
- At least 40% of the floor area on the ground floor is dedicated and designed for non-residential uses
- Any of these is true:
- All of these are true:
- Any of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- The residential units are part of a stacked, mixed-use building
- The residential units occupy no more than 30% of the ground floor area
- Any of these is true:
- All of these are true:
- Any of these is true:
- None of these is true:
- The lot abuts US-2
- The residential use is developed as part of a mixed-use development with at least 3,000 square feet of commercial space adjacent to US-2
- None of these is true:
- None of these is true:
- 30% or more of the building footprint will be within the HOC commercial buffer
- 3,000 square feet or more of the building footprint will be within the HOC commercial buffer
- Any of these is true:
- All of these are true:
- The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is attached
- The transitional housing or permanent supportive housing is built as a detached, attached, or stacked building form is stacked
- None of these is true:
- The lot is an existing lot, not a lot created by a new division
- The lot is an existing lot, not a lot created by a new division
- None of these is true:
- The lot has a driveway
- The lot has a driveway
- The rear lot line abuts an alley
- None of these is true:
- The rear lot line abuts an alley
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is more than 1