RMF · Residential Multifamily
Spokane, WA · SMC 17C.111 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Unit Residential Building | Home✓ ADU✓ | — | — | — | — |
| Manufactured Home | — | — | — | — | |
| Middle housing | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Multi-Unit Residential Building | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Mobile Home Parks | — | — | — | Home✓ ADU✓ | — |
| Group Living | — | — | — | — | |
| Alternative or Post Incarceration Facilities | — | — | — | — | HomeH ADU✓ |
| Co-living | — | — | — | — | Home✓ ADU✓ |
| Single Room Occupancy (SRO) | — | — | — | — | Home✓ ADU✓ |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set SMC 17C.111.200(C)(1) | 435,600 sq ft SMC 17C.345.120(B)
for Mobile Home Parks (4+ units) |
| Minimum frontage | ||
| Minimum density | 15 units per acre SMC Table 17C.111.205-1; 17C.111.210(B) | 4 units per acre SMC 17C.345.120(E)
for Mobile Home Parks (4+ units) |
| Maximum density | No limit SMC Table 17C.111.205-1 | 10 units per acre SMC 17C.345.120(E)
for Mobile Home Parks (4+ units) |
| Maximum residents | 2.5 × (lot area ÷ 1,000) persons SMC 17C.330.120(A)(3); Table 17C.330.120-1; 17C.111.110(A)(1)(a) | Not set SMC 17C.111.210
for Co-living (group living); Single Room Occupancy (SRO) (group living) |
| Maximum sleeping units | Not set SMC 17C.330.120 | No limit SMC Table 17C.111.205-1; 17C.111.210(F)
for Co-living (group living); Single Room Occupancy (SRO) (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC Table 17C.111.205-2; 17C.111.235(C) | 20 ft SMC 17C.345.120(C)(1)(a)-(b)
for Mobile Home Parks (4+ units) |
| Side setback | 20 ft SMC 17C.345.120(C)(1)(a)
for Mobile Home Parks (4+ units) | |
| Street side setback | 5 ft SMC Table 17C.111.205-2 | 20 ft SMC 17C.345.120(C)(1)(b)
for Mobile Home Parks (4+ units) |
| Rear setback | 20 ft SMC 17C.345.120(C)(1)(a)
for Mobile Home Parks (4+ units) | |
| Building separation | Not read SMC 17C.111.235(B)(1) | 10 ft SMC 17C.345.120(C)(1)(d)
for Mobile Home Parks (4+ units) |
| Maximum height |
|
|
| Maximum lot coverage | 100% SMC Table 17C.111.205-1; 17C.111.220(B) | |
| Maximum impervious surface | ||
| Minimum parking | 0 spaces per unit SMC 17C.230.110(A); Table 17C.230.020-1; 17C.111.255(C) | 1.5 spaces per unit SMC 17C.345.120(I)
for Mobile Home Parks (4+ units) 0 spaces per resident SMC 17C.230.110(A); Table 17C.230.020-1; 17C.330.120(D)
0 spaces per sleeping unit SMC 17C.230.110(A); Table 17C.230.020-1; 17C.330.120(D)
for Co-living (group living); Single Room Occupancy (SRO) (group living) |
| Minimum open space | Not set SMC Table 17C.111.205-2 | 15% SMC 17C.345.120(D)
for Mobile Home Parks (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units SMC 17C.300.100(B) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft SMC 17C.111.235(B)(1); Table 17C.111.205-2 | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 25 ft SMC Table 17C.111.205-2; 17C.300.130(B)(2); 17C.111.230(E) | |
| Minimum parking | 0 spaces per unit SMC 17C.300.130(A)(3); 17C.230.110(A) | |
| Maximum unit size | 1,000 sq ft SMC 17C.300.110(A)(1)(a); 17C.300.110(A)(2)(b) | |
| Attached to the main house | Not required SMC 17C.300.100(A) | |
| Owner lives on site |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short Subdivision SMC 17G.080.040; Table 17G.061.010-1 | A | up to 9 SMC 17A.020.190 | No limit SMC Table 17C.111.205-1 Minimum density 15 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2) |
Minimum lot size 1,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1 Minimum lot width |
| Subdivision SMC 17G.080.050(D)-(E); Table 17G.061.010-1 | H | 10 or more SMC 17A.020.190 | No limit SMC Table 17C.111.205-1 Minimum density 15 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2) |
Minimum lot size 1,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1 Minimum lot width |
| Binding Site Plan SMC 17G.080.060(C)(1); 17G.080.060(E); Table 17G.061.010-1 | A | — | No limit SMC Table 17C.111.205-1 Minimum density 15 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2) |
Minimum lot size 1,200 sq ft SMC 17C.111.200(C)(1); Table 17C.111.205-1 Minimum lot width |
| Unit Lot Subdivisions SMC 17G.080.065(C); Table 17G.061.010-1 | A21 | up to 9 SMC 17G.080.065(C) | No limit SMC Table 17C.111.205-1 Maximum parent area 87,120 sq ft SMC Table 17C.111.205-1; 17G.080.065(B)(1) Minimum density 15 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2) |
Minimum lot size No limit SMC Table 17C.111.205-1; 17G.080.065(D)(5) Minimum lot depth No limit SMC Table 17C.111.205-1 |
| Unit Lot Subdivisions SMC 17G.080.065(C); Table 17G.061.010-1 | H21 | 10 or more SMC 17G.080.065(C) | No limit SMC Table 17C.111.205-1 Maximum parent area 87,120 sq ft SMC Table 17C.111.205-1; 17G.080.065(B)(1) Minimum density 15 units per acre SMC Table 17C.111.205-1; 17C.111.210(B); 17C.111.210(K)(2) |
Minimum lot size No limit SMC Table 17C.111.205-1; 17G.080.065(D)(5) Minimum lot depth No limit SMC Table 17C.111.205-1 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The manufactured home is a new unit not previously titled to a retail purchaser
- The lot is in a designated historic district
- Residents is at most 12
- Residents is more than 12
- None of these is true:
- Lot is within an Airfield Overlay Zone
- Lot is within an Airfield Overlay Zone
- Lot width is at most 40 ft
- Lot width is more than 40 ft
- Lot was established as of May 27, 1929
- None of these is true:
- Lot was established as of May 27, 1929
- The official zoning map shows a height after the zone symbol with a dash (e.g. RHD-150, CB-150, DTG-100)
- All of these are true:
- Part of the development is within forty feet of an R1 or R2 zone
- The official zoning map shows a height after the zone symbol with a dash (e.g. RHD-150, CB-150, DTG-100)
- None of these is true:
- The official zoning map shows a height after the zone symbol with a dash (e.g. RHD-150, CB-150, DTG-100)
- Part of the development is within forty feet of an R1 or R2 zone
- The application includes an engineer's stormwater drainage plan
- All of these are true:
- The project is exempted from review under the Spokane Regional Stormwater Manual
- The application includes an engineer's stormwater drainage plan
- The site is in an Area of Drainage Concern
- All of these are true:
- The project is exempted from review under the Spokane Regional Stormwater Manual
- The site is in an Area of Drainage Concern
- The application includes an engineer's stormwater drainage plan
- None of these is true:
- The application includes an engineer's stormwater drainage plan
- The project is exempted from review under the Spokane Regional Stormwater Manual
- The lot has an alley at the rear
- None of these is true:
- The lot has an alley at the rear
- The lot with the ADU also has a Short-Term Rental
- None of these is true:
- The lot with the ADU also has a Short-Term Rental
- Main dwelling units on the lot is at least 2