Sign in

MU · Mixed Use (MU)

Spokane Valley, WA · SVMC 19.60; 19.70 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-family
Home✓ ADU✓
————
Dwelling, duplex—
Home✓ ADU—
———
Dwelling, townhouse—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Dwelling, cottage—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Dwelling, multifamily——
Home✓ ADU—
Home✓ ADU—
—
Assisted living/convalescent/ nursing home————
Home✓ ADU—
Community residential facilities (8* residents or less)————
Home✓ ADU—
Community residential facilities (greater than 8* and under 25 residents)————
Home✓ ADU—
Dwelling, congregate————
Home✓ ADU—
Emergency housing————
HomeA1 ADU—
Emergency shelter————
HomeA1 ADU—
Transitional housing————
HomeA ADU—
Permanent supportive housing————
HomeA1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set SVMC 19.70.050(G); 19.70.020 Table 19.70-1 note 4
2,000 sq ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1 note 4
for Dwelling, single-family (1 unit)
Maximum densityNot set SVMC 19.70.050(G); 19.70.020 Table 19.70-1
22 units per acre SVMC 19.70.050(G); 19.70.020 Table 19.70-1
for Dwelling, single-family (1 unit); Dwelling, duplex (2 units); Dwelling, townhouse (2, 3, 4+ units); Dwelling, multifamily (3, 4+ units)
2 × 22 units per acre SVMC 19.40.050(A)(2); 19.70.050(G); 19.70.020 Table 19.70-1
for Dwelling, cottage (2, 3, 4+ units)
Maximum residents20 persons SVMC 19.45.030(B)(1)
Not set SVMC 19.70.020
for Assisted living/convalescent/ nursing home (group living); Dwelling, congregate (group living)
8 persons SVMC 19.60.050
for Community residential facilities (8* residents or less) (group living)
24 persons SVMC 19.60.050
for Community residential facilities (greater than 8* and under 25 residents) (group living)

3. Building standards

StandardValueExceptions
Front setback15 ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1
20 ft SVMC 19.40.050(A)(4)(a)
for Dwelling, cottage (2, 3, 4+ units)
Side setback
  • 5 ft2 SVMC 19.70.050(G); 19.70.020 Table 19.70-1
  • 10 ft3 SVMC 19.70.050(G); 19.70.020 Table 19.70-1; 19.75.020(A)(1)(a); 19.75.030(A)
  • 6 ft2 SVMC 19.40.100(B)(3)
  • 10 ft3 SVMC 19.40.100(B)(3); 19.75.020(A)(1)(a); 19.75.030(A)
for Dwelling, townhouse (2, 3, 4+ units)
Street side setback15 ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Rear setback10 ft SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Maximum height
  • 50 ft4 SVMC 19.70.050(G); 19.70.020 Table 19.70-1
  • Starting at a height of 15 feet at the boundary of an R-1, R-2, R-3, or R-4 zone, the building height may be increased at a ratio of one foot of height for every one foot of horizontal distance from the nearest R-1, R-2, or R-3 zone boundary.5 SVMC 19.75.030(A)(2)(a)
  • 25 ft4 SVMC 19.40.050(B)(2)
  • Starting at a height of 15 feet at the boundary of an R-1, R-2, R-3, or R-4 zone, the building height may be increased at a ratio of one foot of height for every one foot of horizontal distance from the nearest R-1, R-2, or R-3 zone boundary.5 SVMC 19.75.030(A)(2)(a)
for Dwelling, cottage (2, 3, 4+ units)
Maximum lot coverage60% SVMC 19.70.050(G); 19.70.020 Table 19.70-1
Minimum parking2 spaces per unit SVMC 22.50.020(B) Table 22.50-1
1.5 spaces per unit SVMC 19.40.050(A)(6)
for Dwelling, cottage (2, 3, 4+ units)
  • 1.05 spaces per unit6 SVMC 22.50.020(B) Table 22.50-1
  • 1.575 spaces per unit7 SVMC 22.50.020(B) Table 22.50-1
for Dwelling, multifamily (3, 4+ units)
(residents ÷ 4) + employees on the largest shift spaces SVMC 22.50.020(B) Table 22.50-1
for Assisted living/convalescent/ nursing home (group living)
0.25 spaces per resident SVMC 22.50.020(B) Table 22.50-1
for Community residential facilities (8* residents or less) (group living); Community residential facilities (greater than 8* and under 25 residents) (group living)
1 space per sleeping unit SVMC 22.50.020(B) Table 22.50-1
for Dwelling, congregate (group living)
employees on the largest shift + 10 spaces SVMC 19.45.030(B)(5)(a); 19.45.030(B)(5)(c)
for Emergency housing (group living)1; Emergency shelter (group living)1; Transitional housing (group living); Permanent supportive housing (group living)1
Maximum unit sizeNot set SVMC 19.70.020
900 sq ft SVMC 19.40.050(B)(1)
for Dwelling, cottage (2, 3, 4+ units)
Minimum open space
  • 10%8 SVMC 19.70.050(G); 19.70.020 Table 19.70-1; 19.70.050(F)(1)
  • 10 × 0.75%9 SVMC 19.70.050(G); 19.70.020 Table 19.70-1; 19.70.050(F)(1); 19.70.050(F)(2)
Not set SVMC 19.70.050(G); 19.70.020 Table 19.70-1 note 3
for Dwelling, single-family (1 unit)
Maximum units per buildingNot set SVMC 19.70.020
6 units SVMC 19.40.100(B)(1)
for Dwelling, townhouse (2, 3, 4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit SVMC 19.40.030(A)(2)

Building

StandardValueExceptions
Front setback15 ft SVMC 19.40.030(C)(1); 19.70.050(G); 19.70.020 Table 19.70-1
Side setback
  • 5 ft2 SVMC 19.40.030(C)(2); 19.70.050(G); 19.70.020 Table 19.70-1
  • 10 ft3 SVMC 19.40.030(C)(2); 19.70.050(G); 19.70.020 Table 19.70-1; 19.75.020(A)(1)(a); 19.75.030(A)
Rear setback10 ft SVMC 19.40.030(C)(2); 19.70.050(G); 19.70.020 Table 19.70-1
Maximum height
  • 50 ft4 SVMC 19.70.050(G); 19.70.020 Table 19.70-1
  • Starting at a height of 15 feet at the boundary of an R-1, R-2, R-3, or R-4 zone, the building height may be increased at a ratio of one foot of height for every one foot of horizontal distance from the nearest R-1, R-2, or R-3 zone boundary.5 SVMC 19.75.030(A)(2)(a)
Minimum parking1 space per unit SVMC 19.40.030(A)(3); 22.50.020(B) Table 22.50-1
Maximum unit size0.5 × floor area of the main house sq ft SVMC 19.40.030(B)(3)
Attached to the main houseNot required SVMC 19.40.030(A)(2)
Owner lives on siteRequired SVMC 19.40.030(D)(1)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short Subdivision SVMC 20.30.030; 20.20.110 A up to 9 SVMC 20.20.010(L)(1) —
Minimum lot size
2,000 sq ft SVMC 20.20.090(B)(3)(a); 19.70.050(G); 19.70.020 Table 19.70-1 note 4
Minimum lot width
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum lot depth
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum frontage
Not set SVMC 20.20.090(E)
Maximum units per lot
Not set SVMC 20.20.090
Subdivision SVMC 20.30.030; 20.20.100; 20.20.110 H 10 or more SVMC 20.20.010(L)(2) —
Minimum lot size
2,000 sq ft SVMC 20.20.090(B)(3)(a); 19.70.050(G); 19.70.020 Table 19.70-1 note 4
Minimum lot width
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum lot depth
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum frontage
Not set SVMC 20.20.090(E)
Maximum units per lot
Not set SVMC 20.20.090
Binding Site Plan SVMC 20.30.030 A
Minimum lots
Not set SVMC 20.20.010(L)(3)
—
Minimum lot size
2,000 sq ft SVMC 20.20.090(B)(3)(a); 19.70.050(G); 19.70.020 Table 19.70-1 note 4
Minimum lot width
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum lot depth
Not set SVMC 20.20.090(B)(3)(a); 19.70.020
Minimum frontage
Not set SVMC 20.20.090(E)
Maximum units per lot
Not set SVMC 20.20.090

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The site is at least one mile from the nearest property line of any other emergency shelter, emergency housing, permanent supportive housing or transitional parking use
  2. None of these is true:
    • The property abuts a property located in the R-1, R-2, R-3, or R-4 zone (the 10 ft ground level transitional setback applies on that side)
  3. The property abuts a property located in the R-1, R-2, R-3, or R-4 zone (the 10 ft ground level transitional setback applies on that side)
  4. None of these is true:
    • Part of the building lies where the upper level setback plane (15 ft at the R-1, R-2, R-3 or R-4 zone boundary, plus 1 ft of height per 1 ft of distance) is lower than the zone height limit
  5. Part of the building lies where the upper level setback plane (15 ft at the R-1, R-2, R-3 or R-4 zone boundary, plus 1 ft of height per 1 ft of distance) is lower than the zone height limit
  6. Bedrooms in one unit is at most 1
  7. Bedrooms in one unit is at least 2
  8. None of these is true:
    • The project provides at least two of the listed amenities (play or sports courts, playgrounds, trails, swimming pools, gazebos, clubhouses), reducing required open space by up to 25 percent
  9. The project provides at least two of the listed amenities (play or sports courts, playgrounds, trails, swimming pools, gazebos, clubhouses), reducing required open space by up to 25 percent