MFR · Multifamily Residential (MFR)
Spokane Valley, WA · SVMC 19.60; 19.70 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, single-family | Home✓ ADU— | — | — | — | — |
| Dwelling, duplex | — | Home✓ ADU— | — | — | — |
| Dwelling, townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Dwelling, cottage | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Dwelling, multifamily | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Manufactured home park | — | — | — | HomeA ADU— | — |
| Assisted living/convalescent/ nursing home | — | — | — | — | Home✓ ADU— |
| Community residential facilities (8* residents or less) | — | — | — | — | Home✓ ADU— |
| Community residential facilities (greater than 8* and under 25 residents) | — | — | — | — | Home✓ ADU— |
| Dwelling, congregate | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | HomeA ADU— |
| Permanent supportive housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set SVMC 19.70.020 | 5 units SVMC 19.40.080(B)
for Manufactured home park (4+ units) |
| Minimum lot size | Not set SVMC 19.70.020 Table 19.70-1 note 4 | 2,000 sq ft SVMC 19.70.020 Table 19.70-1 note 4
for Dwelling, single-family (1 unit) |
| Maximum density | 22 units per acre SVMC 19.70.020 Table 19.70-1 | 2 × 22 units per acre SVMC 19.40.050(A)(2); 19.70.020 Table 19.70-1
for Dwelling, cottage (2, 3, 4+ units) 12 units per acre SVMC 19.40.080(B); 19.70.020 Table 19.70-1
for Manufactured home park (4+ units) Not set SVMC 19.70.020 Table 19.70-1
for Assisted living/convalescent/ nursing home (group living); Community residential facilities (8* residents or less) (group living); Community residential facilities (greater than 8* and under 25 residents) (group living); Dwelling, congregate (group living); Transitional housing (group living); Permanent supportive housing (group living)1 |
| Maximum residents | Not set SVMC 19.70.020 | 8 persons SVMC 19.60.050
for Community residential facilities (8* residents or less) (group living) 24 persons SVMC 19.60.050
for Community residential facilities (greater than 8* and under 25 residents) (group living) 20 persons SVMC 19.45.030(B)(1)
|
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft SVMC 19.70.020 Table 19.70-1 | 20 ft SVMC 19.40.050(A)(4)(a)
for Dwelling, cottage (2, 3, 4+ units); Manufactured home park (4+ units) |
| Side setback | for Dwelling, townhouse (2, 3, 4+ units) 10 ft SVMC 19.40.080(E) Table 19.40-1
for Manufactured home park (4+ units) | |
| Street side setback | 15 ft SVMC 19.70.020 Table 19.70-1 | 20 ft SVMC 19.40.080(E) Table 19.40-1
for Manufactured home park (4+ units) |
| Rear setback | 10 ft SVMC 19.70.020 Table 19.70-1 | |
| Maximum height |
|
for Dwelling, cottage (2, 3, 4+ units) |
| Maximum lot coverage | 60% SVMC 19.70.020 Table 19.70-1 | |
| Minimum parking | 2 spaces per unit SVMC 22.50.020(B) Table 22.50-1 | 1.5 spaces per unit SVMC 19.40.050(A)(6)
for Dwelling, cottage (2, 3, 4+ units) for Dwelling, multifamily (3, 4+ units) 2.1 spaces per unit SVMC 22.50.020(B) Table 22.50-1
for Manufactured home park (4+ units) (residents ÷ 4) + employees on the largest shift spaces SVMC 22.50.020(B) Table 22.50-1
for Assisted living/convalescent/ nursing home (group living) 0.25 spaces per resident SVMC 22.50.020(B) Table 22.50-1
for Community residential facilities (8* residents or less) (group living); Community residential facilities (greater than 8* and under 25 residents) (group living) 1 space per sleeping unit SVMC 22.50.020(B) Table 22.50-1
for Dwelling, congregate (group living) employees on the largest shift + 5 spaces SVMC 19.45.030(B)(5)(a); 19.45.030(B)(5)(b)
|
| Maximum unit size | Not set SVMC 19.70.020 | 900 sq ft SVMC 19.40.050(B)(1)
for Dwelling, cottage (2, 3, 4+ units) |
| Minimum open space | Not set SVMC 19.70.020 Table 19.70-1 note 3
for Dwelling, single-family (1 unit) 10% SVMC 19.40.080(C)
for Manufactured home park (4+ units) | |
| Maximum units per building | Not set SVMC 19.70.020 | 6 units SVMC 19.40.100(B)(1)
for Dwelling, townhouse (2, 3, 4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short Subdivision SVMC 20.30.030; 20.20.110 | A | up to 9 SVMC 20.20.010(L)(1) | — | Minimum lot size 2,000 sq ft SVMC 20.20.090(B)(3)(a); 19.70.020 Table 19.70-1 note 4 Minimum lot width Not set SVMC 20.20.090(B)(3)(a); 19.70.020 Minimum lot depth Not set SVMC 20.20.090(B)(3)(a); 19.70.020 Minimum frontage Not set SVMC 20.20.090(E) Maximum units per lot Not set SVMC 20.20.090 |
| Subdivision SVMC 20.30.030; 20.20.100; 20.20.110 | H | 10 or more SVMC 20.20.010(L)(2) | — | Minimum lot size 2,000 sq ft SVMC 20.20.090(B)(3)(a); 19.70.020 Table 19.70-1 note 4 Minimum lot width Not set SVMC 20.20.090(B)(3)(a); 19.70.020 Minimum lot depth Not set SVMC 20.20.090(B)(3)(a); 19.70.020 Minimum frontage Not set SVMC 20.20.090(E) Maximum units per lot Not set SVMC 20.20.090 |
| Binding Site Plan SVMC 20.30.030 | A10 | Minimum lots Not set SVMC 20.20.010(L)(3) |
— | Minimum lot size 2,000 sq ft SVMC 20.20.090(B)(3)(a); 19.70.020 Table 19.70-1 note 4 Minimum lot width Not set SVMC 20.20.090(B)(3)(a); 19.70.020 Minimum lot depth Not set SVMC 20.20.090(B)(3)(a); 19.70.020 Minimum frontage Not set SVMC 20.20.090(E) Maximum units per lot Not set SVMC 20.20.090 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The site is at least one mile from the nearest property line of any other emergency shelter, emergency housing, permanent supportive housing or transitional parking use
- None of these is true:
- The property abuts a property located in the R-1, R-2, R-3, or R-4 zone (the 10 ft ground level transitional setback applies on that side)
- The property abuts a property located in the R-1, R-2, R-3, or R-4 zone (the 10 ft ground level transitional setback applies on that side)
- None of these is true:
- Part of the building lies where the upper level setback plane (15 ft at the R-1, R-2, R-3 or R-4 zone boundary, plus 1 ft of height per 1 ft of distance) is lower than the zone height limit
- Part of the building lies where the upper level setback plane (15 ft at the R-1, R-2, R-3 or R-4 zone boundary, plus 1 ft of height per 1 ft of distance) is lower than the zone height limit
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is at least 2
- None of these is true:
- The project provides at least two of the listed amenities (play or sports courts, playgrounds, trails, swimming pools, gazebos, clubhouses), reducing required open space by up to 25 percent
- The project provides at least two of the listed amenities (play or sports courts, playgrounds, trails, swimming pools, gazebos, clubhouses), reducing required open space by up to 25 percent
- The land is to be developed as condominiums or a manufactured home park