Sign in

I · I – Industrial district

South Prairie, WA · SPMC 17.04.060 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-family
HomeH ADU✓1
————
Duplex—
HomeH ADU✓1
———
Multifamily residential uses——
HomeH ADU✓1
HomeH ADU✓1
—
Transitional housing facilities————
HomeH ADU—
Rest homes————
HomeH ADU—
Convalescent homes————
HomeH ADU—
Retirement homes————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size20,000 sq ft SPMC 17.04.060(D)(1)
Maximum residentsNot set SPMC 17.04.060(D)
20 persons SPMC 17.04.040(A)(3)(c)
for Transitional housing facilities (group living)

3. Building standards

StandardValueExceptions
Front setback25 ft SPMC 17.04.060(D)(3)(a)
Side setback20 ft SPMC 17.04.060(D)(3)(b)
Street side setback20 ft SPMC 17.04.060(D)(3)(b); 17.08.150
Rear setback25 ft SPMC 17.04.060(D)(3)(c)
Maximum height
  • 35 ft2 SPMC 17.04.060(D)(5)
  • 60 ft3 SPMC 17.04.060(D)(5)
Maximum stories
  • 2 stories2 SPMC 17.04.060(D)(5)
  • 4 stories3 SPMC 17.04.060(D)(5)
Maximum lot coverage50% SPMC 17.04.060(D)(2)
Minimum parking2 spaces per unit SPMC 17.05.040(B)(1)(a)
  • 1 space per unit4 SPMC 17.05.040(B)(1)(c)
  • 2 spaces per unit5 SPMC 17.05.040(B)(1)(c)
  • 1.8 spaces per unit6 SPMC 17.05.040(B)(1)(c)
for Multifamily residential uses (3, 4+ units)
For uses not specifically identified in this section, the amount of parking required shall be determined by the town planner, based on parking required for similar uses, and, if appropriate, documentation provided by the applicant. SPMC 17.05.040(I)
for Transitional housing facilities (group living); Retirement homes (group living)
(beds in the project ÷ 2) + (employees on the largest shift ÷ 3) spaces SPMC 17.05.040(G)(2)
for Rest homes (group living); Convalescent homes (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SPMC 17.08.060(B)(3)
Minimum lot size20,000 sq ft SPMC 17.08.060(B)(4); SPMC 17.04.060(D)(1)

Building

StandardValueExceptions
Front setback25 ft SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(3)(a)
Side setback20 ft SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(3)(b)
Rear setback25 ft SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(3)(c)
Maximum height
  • 35 ft2 SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(5)
  • 60 ft3 SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(5)
Maximum stories
  • 2 stories2 SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(5)
  • 4 stories3 SPMC 17.08.060(B)(5); SPMC 17.04.060(D)(5)
Minimum parking
  • 0 spaces per unit7 SPMC 17.08.060(B)(7)(c)
  • 1 space per unit8 SPMC 17.08.060(B)(7)(a)
  • 2 spaces per unit9 SPMC 17.08.060(B)(7)(b)
Attached to the main houseNot required SPMC 17.08.060(B)(1); 17.08.060(B)(3)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Planned unit development SPMC 17.04.070(A); 17.04.070(E)(5) H — The density of residential development for PUDs shall be based on the gross density of the underlying zoning district. The planning commission may recommend a dwelling unit density not more than 20 percent greater than that permitted by the underlying zone SPMC 17.04.070(D); 17.04.070(D)(1)-(7)
Minimum parent area
Minimum site acreage for a PUD is established according to the zoning district in which the PUD is located; SPMC 17.04.070(C)(2)
Minimum lot size
No limit SPMC 17.04.070(C)(1)
Subdivision, short SPMC 15.64.060(A) H up to 4 SPMC 15.04.020 —
Minimum lot size
20,000 sq ft SPMC 17.04.060(D)(1)
Minimum lot width
Not set SPMC 17.04.060(D)
Minimum frontage
Not set SPMC 17.04.060(D)
Subdivision SPMC 15.66.070(A) H 5 or more SPMC 15.04.020 —
Minimum lot size
20,000 sq ft SPMC 17.04.060(D)(1)
Minimum lot width
Not set SPMC 17.04.060(D)
Minimum frontage
Not set SPMC 17.04.060(D)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Lot is designated with critical areas or their buffers
    • Lot is in a watershed serving a reservoir for potable water that is or was listed as impaired or threatened under Section 303(d) of the federal Clean Water Act
  2. None of these is true:
    • Building goes above two stories or 35 feet, adding one foot of yard for each foot of extra height
  3. Building goes above two stories or 35 feet, adding one foot of yard for each foot of extra height
  4. Floor area of one unit is at most 400
  5. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at most 49
  6. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at least 50
  7. ADU is within one-half mile walking distance of a major transit stop
  8. All of these are true:
    • Lot area is less than 6,000 sf
    None of these is true:
    • ADU is within one-half mile walking distance of a major transit stop
  9. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • ADU is within one-half mile walking distance of a major transit stop