MU · Low-intensity mixed use
Shelton, WA · SMC 20.10 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Low-density residential: 1—4 dwelling units per lot, and accessory dwellings | Home✓ ADU✓ | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Medium-density residential: 5+ dwelling units per lot, townhomes, apartments, condominiums | — | — | — | Home✓ ADU— | — |
| Group home | — | — | — | — | Home✓ ADU— |
| Rooming house | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 4 units SMC Table 20.06.030(B) | Not set SMC 20.10
for Medium-density residential: 5+ dwelling units per lot, townhomes, apartments, condominiums (4+ units) |
| Minimum units | 4 units SMC Table 20.06.030(B) | 5 units SMC Table 20.06.030(B)
for Medium-density residential: 5+ dwelling units per lot, townhomes, apartments, condominiums (4+ units) |
| Minimum lot size | 6,000 sq ft SMC 20.10.070(A) | |
| Maximum density | 12 units per acre SMC 20.10.020(B) | Not set SMC 20.10.020(B)
for Group home (group living); Rooming house (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft SMC 20.10.070(B) | |
| Maximum front setback | No limit SMC Table 20.06.030(A) | |
| Side setback | 10 ft SMC 20.10.070(C) | |
| Street side setback | 10 ft SMC Table 20.06.030(A) | |
| Rear setback | ||
| Maximum height | No limit SMC 20.10.070(G); Table 20.06.030(A) | |
| Maximum lot coverage | ||
| Maximum impervious surface | ||
| Minimum parking | 2 + (1.5 × (main dwelling units on the lot − 1)) spaces SMC 20.10.080; Table 20.40.100 | 2 spaces per unit SMC 20.10.080; Table 20.40.100
for Low-density residential: 1—4 dwelling units per lot, and accessory dwellings (1, 2 units) Uses which are not specifically listed shall be required to provide the amount of parking corresponding to the most similar listed use as determined by the planning department. SMC 20.40.100
for Group home (group living) 1 space per sleeping unit SMC 20.10.080; Table 20.40.100
for Rooming house (group living) |
| Maximum building floor area | 9,000 sq ft SMC Table 20.06.030(A) | |
| Maximum building footprint | 6,000 sq ft SMC Table 20.06.030(A) |
4. ADU standards
Lot
No standards.
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum stories | ||
| Minimum parking | 1 space per unit SMC 20.64.040(C) | |
| Maximum unit size | the smallest of 1,000, 0.8 × floor area of the main house sq ft SMC 20.64.040(A)-(B) | |
| Attached to the main house | Not required SMC 20.64.040(B); 20.64.040(D) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 19.28.040 | A | 2 to 4 SMC 19.28.010(A); SMC 19.28.010(A); 19.08.220 | — | Minimum lot size 6,000 sq ft SMC 20.10.070(A) |
| Subdivision SMC 19.16.020; 19.16.060(E) | H | Minimum lots 5 lots SMC 19.16.010; 19.08.300 Maximum lots Not set SMC 19.16 |
— | Minimum lot size 6,000 sq ft SMC 20.10.070(A) |
| Binding site plan SMC 19.34.025; 19.34.050 | H11 | Maximum lots Not set SMC 19.34 |
— | Minimum lot size Not set SMC 19.34 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The property adjoins a land use district with greater setbacks
- None of these is true:
- The property adjoins a land use district with greater setbacks
- The project provides a corridor that facilitates pedestrian access through the block or along a creek, lake, or other natural amenity
- None of these is true:
- The project provides a corridor that facilitates pedestrian access through the block or along a creek, lake, or other natural amenity
- The ADU is in a building detached from the main house
- None of these is true:
- The ADU is in a building detached from the main house
- All of these are true:
- The ADU is in a building detached from the main house
- The rear lot line abuts a platted alley
- All of these are true:
- The ADU is in a building detached from the main house
- The rear lot line abuts a platted alley
- All of these are true:
- The property adjoins a land use district with greater setbacks
- The ADU is in a building detached from the main house
- None of these is true:
- The ADU is in a building detached from the main house
- The property adjoins a land use district with greater setbacks
- The project is the establishment of a condominium development