LDSF · Low density single-family residential (LDSF) zoning district
Selah, WA · SMC 10.10 · Official code
By right: 1 unit · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | Home✓ ADU— | — | — | — | — |
| Manufactured homes | Home✓ ADU— | — | — | — | — |
| Mobile/manufactured home parks | — | — | — | HomeH ADU— | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum density | Not set SMC 10.10.030(a) | The density of a park or park expansion shall not exceed the underlying land use designation contained on the city of Selah Urban Growth Area Comprehensive Plan Future Land Use Map. SMC 10.26.030; 10.28.040(e)
for Mobile/manufactured home parks (4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Street side setback | 20 ft SMC 10.08.090 | |
| Rear setback | 20 ft SMC 10.08.090 | |
| Building separation | Not set SMC 10.08.090; SMC 10.10 | 10 ft SMC 10.26.030(9)
for Mobile/manufactured home parks (4+ units) |
| Maximum height | 35 ft SMC 10.08.050 | |
| Maximum lot coverage | 35% SMC 10.08.040 | |
| Minimum parking | 3 spaces per unit SMC 10.34.020; 10.34.120 Table B | 2 spaces per unit SMC 10.26.030(4)
for Mobile/manufactured home parks (4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 10.50.015D; 10.50.015A | A | up to 9 SMC 10.50.010 | Not set SMC 10.10.030(a) | Minimum lot size Minimum lot width Not set SMC 10.10.030(a); 10.50.020 Minimum lot depth Not set SMC 10.50.015A; SMC 10.10.030(a) Minimum frontage Not set SMC 10.50.015A; SMC 10.10.030(a) |
| Subdivision SMC 10.50.016J; 10.50.016K | H | 10 or more SMC 10.50.010 | Not set SMC 10.10.030(a) | Minimum lot size Minimum lot width Not set SMC 10.10.030(a); 10.50.020 Minimum lot depth 85 ft SMC 10.50.023(a)(1) Minimum frontage 24 ft SMC 10.50.023(b)(3) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot's elevation rises or falls more than four feet in the first twenty feet from the front lot line
- The lot's elevation rises or falls more than four feet in the first twenty feet from the front lot line
- Building stories is at most 1
- Building stories is more than 1
- All of these are true:
- Slope class of the lot in the zone's minimum lot size table (<10%, 10-15%, 15-20%, 20-25%, >25%) is one of slope_under_10, slope_10_to_15, slope_15_to_20, slope_20_to_25
- The lot is served by a municipal (public) water and sewage system
- All of these are true:
- Slope class of the lot in the zone's minimum lot size table (<10%, 10-15%, 15-20%, 20-25%, >25%) is one of slope_under_10, slope_10_to_15, slope_15_to_20, slope_20_to_25
- The lot is served by a municipal (public) water and sewage system
- Slope class of the lot in the zone's minimum lot size table (<10%, 10-15%, 15-20%, 20-25%, >25%) is slope_over_25