B-1 · Professional business (B-1) zoning district
Selah, WA · SMC 10.18 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Mixed (residential and commercial) use | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
No standards.
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Street side setback | 15 ft SMC 10.08.090 | |
| Rear setback | 0 ft SMC 10.08.090 | |
| Maximum height | No limit SMC 10.08.050 | |
| Maximum lot coverage | 80% SMC 10.08.040 | |
| Minimum parking | 3 spaces per unit SMC 10.28.040(f); 10.34.020; 10.34.120 Table B | 2 spaces per unit SMC 10.28.040(f); 10.34.020; 10.34.120 Table B
for Mixed (residential and commercial) use (3, 4+ units)1 |
| Minimum open space | 20% SMC 10.08.040 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 10.50.015D; 10.50.015A | A | up to 9 SMC 10.50.010 | Not set SMC 10.18.030(a) | Minimum lot size 7,200 sq ft SMC 10.18.030(a) Minimum lot width Not set SMC 10.18.030(a); 10.50.020 Minimum lot depth Not set SMC 10.50.015A; SMC 10.18.030(a) Minimum frontage Not set SMC 10.50.015A; SMC 10.18.030(a) |
| Subdivision SMC 10.50.016J; 10.50.016K | H | 10 or more SMC 10.50.010 | Not set SMC 10.18.030(a) | Minimum lot size 7,200 sq ft SMC 10.18.030(a) Minimum lot width Not set SMC 10.18.030(a); 10.50.020 Minimum lot depth 85 ft SMC 10.50.023(a)(1) Minimum frontage 24 ft SMC 10.50.023(b)(3) |
| Binding site plan SMC 10.50.014G; 10.50.014C; 10.50.014A-10.50.014B | A | Maximum lots Not set SMC 10.50.014A-10.50.014L |
Not set SMC 10.18.030(a) | Minimum lot size 7,200 sq ft SMC 10.18.030(a) Minimum lot width Not set SMC 10.18.030(a); 10.50.020 Minimum lot depth Not set SMC 10.50.014J(3); SMC 10.18.030(a) Minimum frontage Not set SMC 10.50.014J(3); SMC 10.18.030(a) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The first floor along the street frontage is used for commercial uses, with dwelling units above the first floor or to the back of the building
- The lot is served by a municipal (public) water and sewage system
- None of these is true:
- The lot's elevation rises or falls more than four feet in the first twenty feet from the front lot line
- The lot's elevation rises or falls more than four feet in the first twenty feet from the front lot line
- Building stories is at most 1
- Building stories is more than 1