Sign in

UI U/65 · Urban Industrial

Seattle, WA · SMC 23.50A · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Housing
HomeA1 ADUA1
HomeA1 ADUA1
HomeA1 ADUA1
HomeA1 ADUA1
—
Permanent supportive housing
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
—
Mobile home
HomeA1 ADU—
————
Artist's studio/dwelling
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
—
Caretaker's quarters
HomeA2 ADU—
————
Congregate residence————
HomeA1 ADU—
Assisted living facility————
HomeA1 ADU—
Nursing home————
HomeA1 ADU—
Adult family home————
HomeA1 ADUA1

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum density50 units per acre, ADUs included SMC 23.50A.062(C)(1); 23.42.022(J)
Not set SMC 23.42.049
for Congregate residence (group living)1; Adult family home (group living)1
Maximum sleeping unitsNot set SMC 23.50A.100
4 × ((50 × lot area) ÷ 43,560), rounded down sleeping units SMC 23.50A.062(C)(1); 23.42.049
for Congregate residence (group living)1

3. Building standards

StandardValueExceptions
Maximum height
  • 30 ft3 SMC 23.50A.140(C)
  • 65 ft4 SMC 23.50A.140(B); 23.32
Maximum floor area ratio
  • 4.55 SMC 23.50A.100(A) Table A
  • 46 SMC 23.50A.100(A) Table A
Minimum parking
  • 0 spaces per unit7 SMC 23.54.015 Table B rows G, I
  • 0 spaces per unit8 SMC 23.54.015 Table B row K
  • 0.5 spaces per unit9 SMC 23.54.015 Table B row F
0 spaces per unit SMC 23.54.015 Table B row L
for Permanent supportive housing (1, 2, 3, 4+ units)1
  • 0 spaces per unit7 SMC 23.54.015 Table B rows G, I
  • 0 spaces per unit8 SMC 23.54.015 Table B row K
  • In the case of a use not shown on Table A for 23.54.015, Table B for 23.54.015, or Table C for 23.54.015, the requirements for off-street parking will be determined by the Director based on the requirements for the most comparable use.9 SMC 23.54.015(H)
for Mobile home (1 unit)1
  • 0 spaces per sleeping unit10 SMC 23.54.015 Table B rows G, I, J
  • 0 spaces per sleeping unit11 SMC 23.54.015 Table B row K
  • 0.25 spaces per sleeping unit12 SMC 23.54.015 Table B row D
for Congregate residence (group living)1
0 spaces per bed SMC 23.54.015 Table B row B
for Assisted living facility (group living)1; Nursing home (group living)1
Maximum unit sizeNot set SMC 23.50A.100
800 sq ft SMC 23.84A.032
for Caretaker's quarters (1 unit)2

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 23.42.022(C)

Building

StandardValueExceptions
Maximum height
  • 30 ft3 SMC 23.42.022(E); 23.50A.140(C)
  • 65 ft4 SMC 23.42.022(E); 23.50A.140(B); 23.32
Minimum parking0 spaces per unit SMC 23.42.022(I); 23.54.015 Table B
Maximum unit size
  • 1,000 sq ft13 SMC 23.42.022(G)(1)(a)
  • 1,200 sq ft14 SMC 23.42.022(G)(1)(b)
Attached to the main houseNot required SMC 23.42.022(D)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 23.76.004 Table A; 23.24.050 A up to 9 SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.24.040(A)(9)(b)
Minimum frontage
  • 10 ft15 SMC 23.24.040(A)(9)(a)
  • Not set16 SMC 23.24.040(A)(9)(a)
Subdivision SMC 23.76.004 Table A; 23.76.024 H 10 or more SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.22.100(C)(3)(b)
Minimum frontage
  • 10 ft15 SMC 23.22.100(C)(3)(a)
  • Not set16 SMC 23.22.100(C)(3)(a)
Short subdivision, zero lot line SMC 23.76.004 Table A; 23.24.045Only for: Housing A up to 9 SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.24.045(B)
Subdivision, zero lot line SMC 23.76.004 Table A; 23.22.062Only for: Housing H 10 or more SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.22.062(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The residential use is part of a mixed-use development that includes non-residential uses permitted in UI zones
    • The residential component is no more than 50 percent of the total floor area of the mixed-use development
    • Any of these is true:
      • All dwelling units are live-work units in which the commercial activity qualifies as industrial
      • All dwelling units are caretakers' quarters associated with a business on the same site, with no more than three per business
      • At least 50 percent of the dwelling units are moderate-income units
    None of these is true:
    • The residential use would be within 200 feet of a shoreline
    • The residential use would be within 200 feet of a designated major truck street
  2. All of these are true:
    • The residential use is part of a mixed-use development that includes non-residential uses permitted in UI zones
    • The residential component is no more than 50 percent of the total floor area of the mixed-use development
    • Any of these is true:
      • All dwelling units are live-work units in which the commercial activity qualifies as industrial
      • All dwelling units are caretakers' quarters associated with a business on the same site, with no more than three per business
      • At least 50 percent of the dwelling units are moderate-income units
    • The dwelling unit is occupied by a caretaker or watchperson and is accessory to a nonresidential use on the lot
    None of these is true:
    • The residential use would be within 200 feet of a shoreline
    • The residential use would be within 200 feet of a designated major truck street
  3. The portion of the structure is within 20 feet of an abutting lot in a residential zone
  4. None of these is true:
    • The portion of the structure is within 20 feet of an abutting lot in a residential zone
  5. The lot is within the Stadium Transition Area Overlay District
  6. None of these is true:
    • The lot is within the Stadium Transition Area Overlay District
  7. Any of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  8. All of these are true:
    • Floor area of one unit is less than 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  9. All of these are true:
    • Floor area of one unit is at least 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  10. Any of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  11. All of these are true:
    • Floor area of all units is less than 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  12. All of these are true:
    • Floor area of all units is at least 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  13. Bedrooms in one ADU is at most 2
  14. Bedrooms in one ADU is at least 3
  15. The new lot is proposed with street frontage
  16. None of these is true:
    • The new lot is proposed with street frontage