Sign in

SM-NR 95 · Seattle Mixed—North Rainier

Seattle, WA · SMC 23.48 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Artist's studio/dwelling
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Permanent supportive housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Mobile home
Home✓ ADU—
————
Caretaker's quarters
Home✓1 ADU—
————
Congregate residence————
Home✓ ADU—
Assisted living facility————
Home✓ ADU—
Adult family home————
Home✓ ADU✓
Nursing home————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum densityNot set SMC 23.48.420
No limit SMC 23.48.090(A)
for Assisted living facility (group living)

3. Building standards

StandardValueExceptions
Maximum height
  • 95 ft2 SMC 23.48.025(A)(1); 23.32
  • 135 ft3 SMC 23.48.025(A)(1); 23.32; 23.48.100(A)(2)
Minimum height
  • 45 ft4 SMC 23.48.040(A)(2)(a)
  • 25 ft5 SMC 23.48.040(A)(2)(b)
  • 15 ft6 SMC 23.48.040(A)(2)(c)
Maximum floor area ratio
  • 6.252 SMC 23.48.420 Table A
  • 9.253 SMC 23.48.420 Table A; 23.48.100(B)(2)
Minimum parking
  • 0 spaces per unit7 SMC 23.54.015 Table B rows G, I
  • 0 spaces per unit8 SMC 23.54.015 Table B row K
  • 0.5 spaces per unit9 SMC 23.54.015 Table B row F
0 spaces per unit SMC 23.54.015 Table B row L
for Permanent supportive housing (1, 2, 3, 4+ units)
  • 0 spaces per unit7 SMC 23.54.015 Table B rows G, I
  • 0 spaces per unit8 SMC 23.54.015 Table B row K
  • In the case of a use not shown on Table A for 23.54.015, Table B for 23.54.015, or Table C for 23.54.015, the requirements for off-street parking will be determined by the Director based on the requirements for the most comparable use.9 SMC 23.54.015(H)
for Mobile home (1 unit)
  • 0 spaces per sleeping unit10 SMC 23.54.015 Table B rows G, I, J
  • 0 spaces per sleeping unit11 SMC 23.54.015 Table B row K
  • 0.25 spaces per sleeping unit12 SMC 23.54.015 Table B row D
for Congregate residence (group living)
0 spaces per bed SMC 23.54.015 Table B row B
for Assisted living facility (group living); Nursing home (group living)
Maximum unit sizeNot set SMC 23.48
800 sq ft SMC 23.84A.032
for Caretaker's quarters (1 unit)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 23.42.022(C)

Building

StandardValueExceptions
Maximum height
  • 95 ft2 SMC 23.42.022(E); 23.48.025(A)(1); 23.32
  • 135 ft3 SMC 23.42.022(E); 23.48.025(A)(1); 23.32; 23.48.100(A)(2)
Minimum parking0 spaces per unit SMC 23.42.022(I); 23.54.015 Table B
Maximum unit size
  • 1,000 sq ft13 SMC 23.42.022(G)(1)(a)
  • 1,200 sq ft14 SMC 23.42.022(G)(1)(b)
Attached to the main houseNot required SMC 23.42.022(D)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 23.76.004 Table A; 23.24.050 A up to 9 SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.24.040(A)(9)(b)
Minimum frontage
  • 10 ft15 SMC 23.24.040(A)(9)(a)
  • Not set16 SMC 23.24.040(A)(9)(a)
Subdivision SMC 23.76.004 Table A; 23.76.024 H 10 or more SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.22.100(C)(3)(b)
Minimum frontage
  • 10 ft15 SMC 23.22.100(C)(3)(a)
  • Not set16 SMC 23.22.100(C)(3)(a)
Short subdivision, zero lot line SMC 23.76.004 Table A; 23.24.045Only for: Housing A up to 9 SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.24.045(B)
Subdivision, zero lot line SMC 23.76.004 Table A; 23.22.062Only for: Housing H 10 or more SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.22.062(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The dwelling unit is occupied by a caretaker or watchperson and is accessory to a nonresidential use on the lot
  2. None of these is true:
    • The development meets Section 23.42.055 (affordable units on property owned or controlled by a religious organization) and uses the zone's standards for such development
  3. The development meets Section 23.42.055 (affordable units on property owned or controlled by a religious organization) and uses the zone's standards for such development
  4. Classification of the street the street-facing facade faces on Map A for 23.48.440 (North Rainier): Class 1 Pedestrian Street, Class 2 Pedestrian Street, Neighborhood Green Street, or other street is class_1
  5. Classification of the street the street-facing facade faces on Map A for 23.48.440 (North Rainier): Class 1 Pedestrian Street, Class 2 Pedestrian Street, Neighborhood Green Street, or other street is one of class_2, neighborhood_green
  6. Classification of the street the street-facing facade faces on Map A for 23.48.440 (North Rainier): Class 1 Pedestrian Street, Class 2 Pedestrian Street, Neighborhood Green Street, or other street is other
  7. Any of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  8. All of these are true:
    • Floor area of one unit is less than 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  9. All of these are true:
    • Floor area of one unit is at least 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
  10. Any of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  11. All of these are true:
    • Floor area of all units is less than 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  12. All of these are true:
    • Floor area of all units is at least 1,200
    None of these is true:
    • Lot is inside a regional center or an urban center (Seattle Comprehensive Plan)
    • Lot is within a Station Area Overlay District
    • Lot is within a major transit service area (map adopted by Director's rule)
    • Lot is within a frequent transit service area (map adopted by Director's rule)
  13. Bedrooms in one ADU is at most 2
  14. Bedrooms in one ADU is at least 3
  15. The new lot is proposed with street frontage
  16. None of these is true:
    • The new lot is proposed with street frontage