Sign in

PSM 100/120-150 · Pioneer Square Mixed (PSM 100/120-150)

Seattle, WA · SMC 23.49 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent supportive housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Artist's studio/dwelling
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Mobile home
Home✓ ADU—
————
Caretaker's quarters
Home✓1 ADU—
————
Congregate residence————
Home✓ ADU—
Assisted living facility————
Home✓ ADU—
Nursing home————
Home✓ ADU—
Adult family home————
Home✓ ADU✓

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

No standards.

3. Building standards

StandardValueExceptions
Maximum front setback0 ft SMC 23.66.150(A)-(C)
Maximum height
  • 120 ft2 SMC 23.49.178(D)
  • 150 ft3 SMC 23.49.178(D)(1)-(6)
Minimum height50 ft SMC 23.66.140(B)
Minimum parking0 spaces per unit SMC 23.49.019(A)(1)
0 spaces per sleeping unit SMC 23.49.019(A)(1)
for Congregate residence (group living)
0 spaces per bed SMC 23.49.019(A)(1)
for Assisted living facility (group living); Nursing home (group living)
Maximum unit sizeNot set SMC 23.49.178; 23.66.140; 23.66.150
800 sq ft SMC 23.84A.032
for Caretaker's quarters (1 unit)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 23.42.022(C)

Building

StandardValueExceptions
Maximum height
  • 120 ft2 SMC 23.42.022(E); 23.49.178(D)
  • 150 ft3 SMC 23.42.022(E); 23.49.178(D)(1)-(6)
Minimum parking0 spaces per unit SMC 23.42.022(I); 23.54.015 Table B
Maximum unit size
  • 1,000 sq ft4 SMC 23.42.022(G)(1)(a)
  • 1,200 sq ft5 SMC 23.42.022(G)(1)(b)
Attached to the main houseNot required SMC 23.42.022(D)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 23.76.004 Table A; 23.24.050 A up to 9 SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.24.040(A)(9)(b)
Minimum frontage
  • 10 ft6 SMC 23.24.040(A)(9)(a)
  • Not set7 SMC 23.24.040(A)(9)(a)
Subdivision SMC 23.76.004 Table A; 23.76.024 H 10 or more SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.22.100(C)(3)(b)
Minimum frontage
  • 10 ft6 SMC 23.22.100(C)(3)(a)
  • Not set7 SMC 23.22.100(C)(3)(a)
Short subdivision, zero lot line SMC 23.76.004 Table A; 23.24.045Only for: Housing A up to 9 SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.24.045(B)
Subdivision, zero lot line SMC 23.76.004 Table A; 23.22.062Only for: Housing H 10 or more SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.22.062(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The dwelling unit is occupied by a caretaker or watchperson and is accessory to a nonresidential use on the lot
  2. Not all of these are true:
    • Construction does not involve the demolition or removal of any building or structure except as approved pursuant to Section 23.66.115
    • No contributing building or structure has been demolished or removed from the lot within the ten years before the building permit application
    • No portion of the structure has been determined to be contributing pursuant to Section 23.66.032
    • The gross floor area in residential use equals or exceeds the gross floor area of the portion of the structure above 100 feet
    • The project gains bonus or extra residential floor area (or the related extra height) through the incentive provisions of Chapter 23.58A
    • Lot area is at least 7,200 sf
  3. All of these are true:
    • Construction does not involve the demolition or removal of any building or structure except as approved pursuant to Section 23.66.115
    • No contributing building or structure has been demolished or removed from the lot within the ten years before the building permit application
    • No portion of the structure has been determined to be contributing pursuant to Section 23.66.032
    • The gross floor area in residential use equals or exceeds the gross floor area of the portion of the structure above 100 feet
    • The project gains bonus or extra residential floor area (or the related extra height) through the incentive provisions of Chapter 23.58A
    • Lot area is at least 7,200 sf
  4. Bedrooms in one ADU is at most 2
  5. Bedrooms in one ADU is at least 3
  6. The new lot is proposed with street frontage
  7. None of these is true:
    • The new lot is proposed with street frontage