Sign in

IDR 45/125-270 · International District Residential (IDR 45/125-270)

Seattle, WA · SMC 23.49 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent supportive housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Artist's studio/dwelling
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Mobile home
Home✓ ADU—
————
Caretaker's quarters
Home✓1 ADU—
————
Congregate residence————
Home✓ ADU—
Assisted living facility————
Home✓ ADU—
Nursing home————
Home✓ ADU—
Adult family home————
Home✓ ADU✓

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size
  • 21,000 sq ft2 SMC 23.49.242(B)
  • Not set3 SMC 23.49.242(B)

3. Building standards

StandardValueExceptions
Maximum height
  • 125 ft4 SMC 23.49.236(B)(1)
  • 270 ft5 SMC 23.49.236(B)(1); 23.49.023
  • 280 ft6 SMC 23.49.236(B)(1); 23.49.023; 23.49.008(F)-(G)
Maximum floor area ratioNo limit SMC 23.49.011(B)(1)(f)
Minimum parking0 spaces per unit SMC 23.49.019(A)(1)
0 spaces per sleeping unit SMC 23.49.019(A)(1)
for Congregate residence (group living)
0 spaces per bed SMC 23.49.019(A)(1)
for Assisted living facility (group living); Nursing home (group living)
Maximum unit sizeNot set SMC 23.49.236; 23.49.242; 23.49.250
800 sq ft SMC 23.84A.032
for Caretaker's quarters (1 unit)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units SMC 23.42.022(C)

Building

StandardValueExceptions
Maximum height
  • 125 ft4 SMC 23.42.022(E); 23.49.236(B)(1)
  • 270 ft5 SMC 23.42.022(E); 23.49.236(B)(1); 23.49.023
  • 280 ft6 SMC 23.42.022(E); 23.49.236(B)(1); 23.49.023; 23.49.008(F)-(G)
Minimum parking0 spaces per unit SMC 23.42.022(I); 23.54.015 Table B
Maximum unit size
  • 1,000 sq ft7 SMC 23.42.022(G)(1)(a)
  • 1,200 sq ft8 SMC 23.42.022(G)(1)(b)
Attached to the main houseNot required SMC 23.42.022(D)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 23.76.004 Table A; 23.24.050 A up to 9 SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.24.040(A)(9)(b)
Minimum frontage
  • 10 ft9 SMC 23.24.040(A)(9)(a)
  • Not set10 SMC 23.24.040(A)(9)(a)
Subdivision SMC 23.76.004 Table A; 23.76.024 H 10 or more SMC 23.84A.036 —
Minimum lot width
10 ft SMC 23.22.100(C)(3)(b)
Minimum frontage
  • 10 ft9 SMC 23.22.100(C)(3)(a)
  • Not set10 SMC 23.22.100(C)(3)(a)
Short subdivision, zero lot line SMC 23.76.004 Table A; 23.24.045Only for: Housing A up to 9 SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.24.045(B)
Subdivision, zero lot line SMC 23.76.004 Table A; 23.22.062Only for: Housing H 10 or more SMC 23.84A.036 —
Minimum lot size
Not set SMC 23.22.062(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The dwelling unit is occupied by a caretaker or watchperson and is accessory to a nonresidential use on the lot
  2. Building height is more than 170
  3. Building height is at most 170
  4. None of these is true:
    • The project gains bonus or extra residential floor area (or the related extra height) through the incentive provisions of Chapter 23.58A
  5. All of these are true:
    • The project gains bonus or extra residential floor area (or the related extra height) through the incentive provisions of Chapter 23.58A
    None of these is true:
    • The structure includes at least ten dwelling units of at least 900 gross square feet with three or more bedrooms, each with access to a qualifying outdoor amenity area on the same story
    • The structure complies with the Chapter 23.58C performance option with at least ten units over 400 square feet restricted at or below 50 percent of median income
  6. All of these are true:
    • The project gains bonus or extra residential floor area (or the related extra height) through the incentive provisions of Chapter 23.58A
    • Any of these is true:
      • The structure includes at least ten dwelling units of at least 900 gross square feet with three or more bedrooms, each with access to a qualifying outdoor amenity area on the same story
      • The structure complies with the Chapter 23.58C performance option with at least ten units over 400 square feet restricted at or below 50 percent of median income
  7. Bedrooms in one ADU is at most 2
  8. Bedrooms in one ADU is at least 3
  9. The new lot is proposed with street frontage
  10. None of these is true:
    • The new lot is proposed with street frontage