RBX · Regional Business Mix
SeaTac, WA · SMC 15.200.030(O); 15.400.200 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Multi-Family | — | — | — | — | |
| Co-Living | — | — | — | — | |
| College Dormitory | — | — | — | — | |
| Community Residential Facility I | — | — | — | — | Home✓ ADU— |
| Community Residential Facility II | — | — | — | — | Home✓ ADU— |
| Convalescent Center/Nursing Home | — | — | — | — | Home✓ ADU— |
| Emergency Housing | — | — | — | — | Home✓ ADU— |
| Emergency Shelters | — | — | — | — | Home✓ ADU— |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU— |
| Transitional Housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | 7 units SMC 15.105.130 Multi-Family | |
| Maximum residents | Not set SMC 15.400.200 | 5 persons SMC 15.465.400(B)(1)(a)
for Community Residential Facility I (group living) No limit SMC 15.465.400(B)(2)
for Community Residential Facility II (group living) 80 persons SMC 15.465.350(B)(2)(a)(iii)
for Emergency Housing (group living); Emergency Shelters (group living) |
| Maximum beds | Not set SMC 15.400.200 | floor area of all units ÷ 35, rounded down beds SMC 15.465.350(B)(2)(a)(iii)
for Emergency Housing (group living); Emergency Shelters (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum height | Limited by FAA and Fire Department regulations. SMC 15.400.200 | |
| Maximum lot coverage | 75% SMC 15.400.200 | |
| Minimum parking | Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker SMC 15.455.120 | for Multi-Family (4+ units)1 for Co-Living (group living)1 0.5 spaces per sleeping unit SMC 15.455.120
for College Dormitory (group living)2 Parking study from the applicant documenting the number of parking spaces needed by the land use submitted to and approved by the decision maker. SMC 15.455.120
for Community Residential Facility I (group living) Parking plan based on population served and projected needs should be submitted and approved by the City Manager, or designee. SMC 15.455.120
for Community Residential Facility II (group living) 0.2 spaces per bed SMC 15.455.120
for Convalescent Center/Nursing Home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, Short SMC 14.18.050(A) | A | up to 9 SMC 14.18.020(B) | — | Minimum lot size Not set SMC 15.400.200 |
| Subdivision, Long SMC 14.20.057(A) | H | 10 or more SMC 14.20.010 | — | Minimum lot size Not set SMC 15.400.200 |
| Binding Site Plan SMC 14.22.020(A) | A | 2 or more SMC 14.22.020(E) | — | Minimum lot size Not set SMC 14.22 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Any of these is true:
- None of these is true:
- Project fronts International Blvd or S 188th St
- At least 50% of the building's ground floor is retail, service, or commercial use
- None of these is true:
- Operated in direct connection with and accessory to an established College/University use on the same site
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- Lot is within a one-mile radius of SeaTac International Airport
- All of these are true:
- Lot is within a one-half-mile radius of a major transit stop
- Lot is within a one-mile radius of SeaTac International Airport
- None of these is true:
- Lot is within a one-mile radius of SeaTac International Airport
- Lot is within a one-half-mile radius of a major transit stop