TC E · Reserve zone (TC-E)
Sammamish, WA · SMC 21.07.020(G); 21.07.050(B) · Official code
By right: 1 unit · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single detached | Home✓ ADU✓ | — | — | — | — |
| Community residential facility, I | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot width | 30 ft SMC 21.07.050(B)(9) | |
| Minimum density | No limit SMC 21.07.050(B) | Not set SMC 21.07.050(B)(3)
for Community residential facility, I (group living) |
| Maximum density | 1 units per acre, a fraction of 0.5 or more rounds up, on the net lot area SMC 21.07.050(B); 21.07.050(C)(1)(e); 21.07.050(F)(4) | Not set SMC 21.07.050(B)
for Community residential facility, I (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft SMC 21.07.050(B) | |
| Side setback | 10 ft SMC 21.07.050(B) | |
| Rear setback | 20 ft SMC 21.07.050(B) | |
| Maximum height | 35 ft SMC 21.07.050(B) | |
| Minimum parking | 2 spaces per unit SMC 21.07.080(C)(1) | 0.5 × bedrooms in the whole project spaces SMC 21.07.080(C)(1)
for Community residential facility, I (group living) |
| Minimum open space | 40% SMC 21.07.060(D)(2)(g) | Not set SMC 21.07.050(B)
for Community residential facility, I (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit SMC 21.07.040(D)(4)(a) |
Building
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision SMC 21.09.010(B)(4) | A | up to 9 SMC 21.02.060(D)(3)(a) | — | Minimum lot width 30 ft SMC 21.07.050(B) |
| Subdivision SMC 21.09.010(B)(4) | H | 10 or more SMC 21.02.060(B)(32); 21.02.060(D)(3)(a) | — | Minimum lot width 30 ft SMC 21.07.050(B) |
| Unit lot subdivision SMC 21.02.060(H)(2); 21.09.010(B)(4) | A5 | up to 9 SMC 21.02.060(H)(2); 21.02.060(D)(3)(a) | — | Minimum lot size Not set SMC 21.02.060(H)(3) |
| Unit lot subdivision SMC 21.02.060(H)(2); 21.09.010(B)(4) | H5 | 10 or more SMC 21.02.060(H)(2); 21.02.060(B)(32); 21.02.060(D)(3)(a) | — | Minimum lot size Not set SMC 21.02.060(H)(3) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The property line abuts R-1 through R-8, TC-C or TC-E zones
- None of these is true:
- The property line abuts R-1 through R-8, TC-C or TC-E zones
- None of these is true:
- One ADU is wholly contained within the existing residence (or a basement or attic)
- One ADU is wholly contained within the existing residence (or a basement or attic)
- No dwelling units are stacked on other dwelling units or another use