Sign in

BD · Baltimore District (BD)

Ruston, WA · RMC 25.01.050 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live-Work Units
Home✓ ADU—
————
Mixed-Use Buildings
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Dwelling, Cottage Housing—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Dwelling, Rowhouse——
Home✓ ADU—
Home✓ ADU—
—
Dwelling, Courtyard Building——
Home✓ ADU—
Home✓ ADU—
—
Dwelling, Fiveplex———
Home✓ ADU—
—
Dwelling, Sixplex———
Home✓ ADU—
—
Dwelling, High-Rise Multifamily Building———
Home✓ ADU—
—
Adult Family Home————
Home✓ ADU—
Nursing, Convalescent or Retirement Home————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set RMC 25.01.050
5 units RMC 25.99.040
for Dwelling, Fiveplex (4+ units)
6 units RMC 25.99.040
for Dwelling, Sixplex (4+ units)
Minimum unitsNot set RMC 25.01.050
5 units RMC 25.99.040
for Dwelling, Fiveplex (4+ units)
6 units RMC 25.99.040
for Dwelling, Sixplex (4+ units)
Minimum lot sizeNo limit RMC 25.01.050(d)
Maximum residents6 persons RMC 25.99.010
Not set RMC 25.07.020
for Nursing, Convalescent or Retirement Home (group living)

3. Building standards

StandardValueExceptions
Front setback0 ft RMC 25.01.050(f)(1)(A)
Side setback0 ft RMC 25.01.050(f)(1)(C)
Rear setback25 ft RMC 25.01.050(f)(1)(B)
Maximum height
  • 35 ft1 RMC 25.01.050(e)
  • 45 ft2 RMC 25.01.050(e)
Maximum stories
  • 2 stories1 RMC 25.01.050(e)
  • 3 stories2 RMC 25.01.050(e)
Minimum storiesNot set RMC 25.01.050
4 stories RMC 25.99.040
for Dwelling, High-Rise Multifamily Building (4+ units)
Minimum parking
  • 0 spaces per unit3 RMC 25.01.090(a)(4)(A)
  • 2 spaces per unit4 RMC 25.01.090(a)(4)(B)
  • 1 space per unit5 RMC 25.01.090(a)(4)(C)
Not set RMC 25.01.090(a)
for Live-Work Units (1 unit); Mixed-Use Buildings (1, 2 units); Adult Family Home (group living)
2 spaces per unit RMC 25.01.090(a)(3)
for Mixed-Use Buildings (3, 4+ units); Dwelling, High-Rise Multifamily Building (4+ units)
0.25 spaces per bed RMC 25.01.090(a)(1)(H)
for Nursing, Convalescent or Retirement Home (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision RMC 29.02.010(f)(1) A up to 4 RMC 29.02.010(b)(14) —
Minimum lot size
No limit RMC 25.01.050(d)
Minimum lot width
Not set RMC 25.01.050
Subdivision RMC 29.02.010(g); 29.02.010(j) H 5 or more RMC 29.02.010(b)(15) —
Minimum lot size
No limit RMC 25.01.050(d)
Minimum lot width
Not set RMC 25.01.050

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Structure has frontage on 51st Street
  2. Structure has frontage on 51st Street
  3. Within one-half mile walking distance of a major transit stop
  4. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Within one-half mile walking distance of a major transit stop
  5. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Within one-half mile walking distance of a major transit stop