Sign in

RC · Resource Conservation

Renton, WA · RMC 4-2-020(B) · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family
Home✓ ADU✓
————
Manufactured homes
Home✓ ADU—
————
Permanent supportive housing
HomeH ADU—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Transitional housing
HomeH ADU—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Middle housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Cottage——
Home✓ ADU✓
Home✓ ADU✓
—
Adult family home————
Home✓ ADU✓
Co-living housing————
Home✓1 ADU—
Group homes II————
HomeA2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot read RMC 4-2-110(G); 4-2-080(A)(32)
100 units RMC 4-2-080(A)(88)
for Permanent supportive housing (4+ units); Transitional housing (4+ units)
Minimum unitsNot read RMC 4-2-110(F)
3 units RMC 4-11-030
for Cottage (4+ units)
Minimum lot sizeNot read RMC 4-2-110(A)
Minimum lot widthNot read RMC 4-2-110(A)
Minimum lot depthNot read RMC 4-2-110(A)
Minimum frontageNot read RMC 4-2-110(A)
Minimum densityNot read RMC 4-2-110(A)
Maximum densityNot read RMC 4-2-110(A)
subject to the density and dimensional standards of the corresponding zone or to no more than one hundred (100) dwelling units, whichever is less RMC 4-2-080(A)(88); RMC 4-2-110(A)
for Permanent supportive housing (1, 2, 3, 4+ units); Transitional housing (1, 2, 3, 4+ units)
Minimum development sizeNot read RMC 4-2-110(A)
Maximum residentsNot set RMC 4-2-060(D); 4-2-080(A)
  • 6 persons3 RMC 4-11-010(S)
  • 8 persons4 RMC 4-11-010(S)
for Adult family home (group living)

3. Building standards

StandardValueExceptions
Front setbackNot read RMC 4-2-110(A)
Maximum front setbackNot read RMC 4-2-110(A)
Side setbackNot read RMC 4-2-110(A)
Total side setbacksNot read RMC 4-2-110(A)
Street side setbackNot read RMC 4-2-110(A)
Rear setbackNot read RMC 4-2-110(A)
Building separationNot read RMC 4-2-110(A)
Maximum heightNot read RMC 4-2-110(A)
Maximum storiesNot read RMC 4-2-110(A)
Minimum heightNot read RMC 4-2-110(A)
Minimum storiesNot read RMC 4-2-110(A)
Maximum lot coverageNot read RMC 4-2-110(A)
Maximum impervious surfaceNot read RMC 4-2-110(A)
Maximum floor area ratioNot read RMC 4-2-110(A)
Minimum parkingDepartment staff shall determine which of the below uses is most similar based upon staff experience with various uses and information provided by the applicant. The amount of required parking for uses not listed above shall be the same as for the most similar use listed below. RMC 4-4-080(F)(10)(e)
2 spaces per unit RMC 4-4-080(F)(10)(e)
for Single-family (1 unit); Manufactured homes (1 unit); Adult family home (group living)
Not read RMC 4-2-110(F)
for Middle housing (2, 3, 4+ units)
  • 1 space per unit5 RMC 4-4-080(F)(10)(e)
  • 1.4 spaces per unit6 RMC 4-4-080(F)(10)(e)
  • 1.6 spaces per unit7 RMC 4-4-080(F)(10)(e)
for Cottage (3, 4+ units)
  • 0 spaces per sleeping unit8 RMC 4-4-080(F)(10)(e)
  • 0.25 spaces per sleeping unit9 RMC 4-4-080(F)(10)(e)
for Co-living housing (group living)1
Maximum unit sizeNot read RMC 4-2-110(A)
1,500 sq ft RMC 4-11-030
for Cottage (3, 4+ units)
Maximum building floor areaNot read RMC 4-2-110(A)
Maximum lot sizeNot read RMC 4-2-110(A)
Maximum building footprintNot read RMC 4-2-110(A)
Minimum open spaceNot read RMC 4-2-110(A)
Maximum units per buildingNot read RMC 4-2-110(A)

4. ADU standards

Lot

StandardValueExceptions
Maximum unitsNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Minimum lot sizeNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)

Building

StandardValueExceptions
Front setbackNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Side setbackNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Rear setbackNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Maximum heightNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Maximum storiesNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Minimum parkingNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Maximum unit sizeNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Attached to the main houseNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)
Owner lives on siteNot read RMC 4-2-110(C); 4-2-080(A)(7)(d)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision RMC 4-7-050(C)(4) A up to 9 RMC 4-7-070(C)(1) —
Minimum lot size
Not read RMC 4-2-110(A)
Minimum lot width
Not read RMC 4-2-110(A)
Minimum lot depth
Not read RMC 4-2-110(A)
Subdivision RMC 4-7-050(D)(5) H 10 or more RMC 4-7-080(C); 4-11-160(WW) —
Minimum lot size
Not read RMC 4-2-110(A)
Minimum lot width
Not read RMC 4-2-110(A)
Minimum lot depth
Not read RMC 4-2-110(A)
Unit lot subdivision RMC 4-7-090(D)(1)Only for: Middle housing A up to 9 RMC 4-7-090(D)(1) The density of the parent site shall not exceed the maximum net density of the zone, except for middle housing, which shall conform to the maximum number of dwelling units allowed pursuant to RMC 4-2-110F6, Maximum Dwelling Units per Legal Lot. RMC 4-7-090(F)(4)
Minimum lot size
Individual unit lots created for townhouses, middle housing, or cottage house development are exempt from the following standards of RMC 4-2-110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. RMC 4-7-090(E)(1)
Minimum lot width
Individual unit lots created for townhouses, middle housing, or cottage house development are exempt from the following standards of RMC 4-2-110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. RMC 4-7-090(E)(1)
Minimum lot depth
Individual unit lots created for townhouses, middle housing, or cottage house development are exempt from the following standards of RMC 4-2-110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. RMC 4-7-090(E)(1)
Maximum units per lot
1 unit RMC 4-7-090(F)(4)
Unit lot subdivision RMC 4-7-090(D)(2); 4-7-050(D)(5)Only for: Middle housing H 10 or more RMC 4-7-090(D)(2) The density of the parent site shall not exceed the maximum net density of the zone, except for middle housing, which shall conform to the maximum number of dwelling units allowed pursuant to RMC 4-2-110F6, Maximum Dwelling Units per Legal Lot. RMC 4-7-090(F)(4)
Minimum lot size
Individual unit lots created for townhouses, middle housing, or cottage house development are exempt from the following standards of RMC 4-2-110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. RMC 4-7-090(E)(1)
Minimum lot width
Individual unit lots created for townhouses, middle housing, or cottage house development are exempt from the following standards of RMC 4-2-110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. RMC 4-7-090(E)(1)
Minimum lot depth
Individual unit lots created for townhouses, middle housing, or cottage house development are exempt from the following standards of RMC 4-2-110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. RMC 4-7-090(E)(1)
Maximum units per lot
1 unit RMC 4-7-090(F)(4)
Hillside subdivision RMC 4-7-050(C)(4); 4-7-220(C) A10 up to 9 RMC 4-7-070(C)(1); 4-11-160(XX) —
Minimum lot size
Not read RMC 4-2-110(A)
Minimum lot width
Not read RMC 4-2-110(A)
Minimum lot depth
Not read RMC 4-2-110(A)
Hillside subdivision RMC 4-7-050(D)(5); 4-7-220(C) H10 10 or more RMC 4-11-160(WW) —
Minimum lot size
Not read RMC 4-2-110(A)
Minimum lot width
Not read RMC 4-2-110(A)
Minimum lot depth
Not read RMC 4-2-110(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot is within 1/4 mile walking distance of a Major Transit Stop (Area B walkshed)
  2. Residents is at most 6
  3. None of these is true:
    • DSHS determines the home may serve up to eight adults
  4. DSHS determines the home may serve up to eight adults
  5. Bedrooms in one unit is at most 1
  6. Bedrooms in one unit is 2
  7. Bedrooms in one unit is at least 3
  8. Lot is within 1/2 mile walking distance of a Major Transit Stop (Area A)
  9. None of these is true:
    • Lot is within 1/2 mile walking distance of a Major Transit Stop (Area A)
  10. Any of these is true:
    • The average slope of the site is twenty percent (20%)
    • A street in the subdivision has grades greater than fifteen percent (15%) at any point