RM-10 · Medium density multiple-family residential zone
Puyallup, WA · PMC 20.25 · Official code
By right: 2 units, 3 units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Manufactured/mobile home | — | — | — | — | |
| Dwelling, duplex | — | Home✓ ADU— | — | — | — |
| Dwelling, triplex | — | — | Home✓ ADU— | — | — |
| Dwelling, fourplex | — | — | — | — | |
| Townhouse | — | — | — | — | |
| Retirement apartments | — | — | — | — | |
| Congregate living facility | — | — | — | — | |
| Affordable retirement apartments | — | — | — | — | |
| Senior housing complex | — | — | — | — | |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Boardinghome | — | — | — | — | Home✓ ADU— |
| Residential care facility | — | — | — | — | Home✓ ADU— |
| Residential treatment facility | — | — | — | — | |
| Nursing home | — | — | — | — | HomeH ADU— |
| Assisted living facility | — | — | — | — | HomeH ADU— |
| Boardinghouse | — | — | — | — | HomeH ADU— |
| Fraternity houses | — | — | — | — | HomeH ADU— |
| Co-living | — | — | — | — | |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Emergency housing, scattered site units | — | — | — | — | Home✓ ADU— |
| Emergency shelter, scattered site units | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set PMC 20.25.022 | |
| Minimum units | Not set PMC 20.25.010 | |
| Minimum lot size | 2,400 sq ft PMC 20.25.020(1) | 4,800 sq ft PMC 20.25.010(2)
for Dwelling, duplex (2 units) 7,200 sq ft PMC 20.25.010(3)
for Dwelling, triplex (3 units) |
| Minimum lot width | 30 ft PMC 20.25.020(2) | |
| Minimum lot depth | 70 ft PMC 20.25.020(3) | |
| Minimum frontage | 15 ft PMC 20.25.020(10) | |
| Minimum density | 8 units per acre PMC 20.25.023(1) | Not set PMC 20.29.025
for Co-living (group living)2 |
| Maximum density | 28 units per acre, a fraction of 0.5 or more rounds up PMC 20.25.022(1); 20.25.040(16)(a)
For a senior housing complex, the overall density of the project shall be determined by the mix of uses contained therein, according to the following standards: PMC 20.25.015(12)(e); 20.25.015(12)(e)(i)-(iii)
for Senior housing complex (4+ units)4 | |
| Maximum residents | Not set PMC 20.25.020 | 8 persons PMC 20.15.010
6 persons PMC 20.25.010(14)
4 persons PMC 20.25.010(15)
for Residential care facility (group living) |
| Maximum sleeping units | Not set PMC 20.25.020 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 3 ft PMC 20.25.020(6) | |
| Street side setback | 10 ft PMC 20.25.020(7) | |
| Rear setback | 15 ft PMC 20.25.020(5) | |
| Building separation | 10 ft PMC 20.25.020(11) | |
| Maximum height | ||
| Maximum lot coverage | 60% PMC 20.25.020(9) | |
| Maximum floor area ratio | 1.5 PMC 20.25.020(18) | |
| Minimum parking | 1 space per unit PMC 20.25.010(16)(b)
0.5 spaces per unit PMC 20.25.010(17)(b)
0.75 spaces per unit PMC 20.25.040(16)(b)
Parking shall be provided as follows: PMC 20.25.015(12)(a); 20.25.015(12)(a)(i)-(iv)
for Senior housing complex (4+ units)4 0.3333 spaces per bed PMC 20.55.010(24)
for Nursing home (group living) Where ambiguity exists in the application of off-street parking requirements, or where the parking requirements for a use are not specifically defined herein, the parking requirements for such use shall be determined by the planning director or the director's designee and such determination shall be based upon the requirements for the most comparable use specified in this chapter. PMC 20.55.015
for Assisted living facility (group living) 0.5 spaces per sleeping unit PMC 20.55.010(26)
for Boardinghouse (group living); Fraternity houses (group living) | |
| Maximum unit size | Not set PMC 20.25.020 | 300 sq ft PMC 20.29.020(1)(a)
for Co-living (group living)2 |
| Minimum open space | 25% PMC 20.25.020(13) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short PMC 19.07.100(1) | A | up to 9 PMC 19.07.020 | — | Minimum lot size 2,400 sq ft PMC 20.25.020(1) Minimum lot width 30 ft PMC 20.25.020(2) Minimum lot depth 70 ft PMC 20.25.020(3) Minimum frontage 15 ft PMC 20.25.020(10) |
| Subdivision, major PMC 19.08.120 | H | 10 or more PMC 19.08.010 | — | Minimum lot size 2,400 sq ft PMC 20.25.020(1) Minimum lot width 30 ft PMC 20.25.020(2) Minimum lot depth 70 ft PMC 20.25.020(3) Minimum frontage 15 ft PMC 20.25.020(10) |
| Unit lot subdivision PMC 19.11.020(1)(a) | A | 2 or more PMC 19.04.210 | — | Minimum lot size Unit lot(s) are not subject to PMC Title 20 dimensional standards of the applicable zoning district but shall meet the applicable building fire separation standards, fire access, adequacy of emergency vehicle access and fire protection water system standards. PMC 19.11.030(1)(d) |
| Residential lot split PMC 19.11.020(2)(a) | A19 | up to 2 PMC 19.11.020(2)(a) | Maximum parent area If a residential lot split results in any lot(s) of a size that would allow for further land division, the property is not eligible for a residential lot split but may be divided under other applicable land subdivision processes (e.g., short plat). PMC 19.11.030(2)(a) |
Minimum lot size 2,400 sq ft PMC 20.25.020(1) Minimum lot width 30 ft PMC 20.25.020(2) Minimum lot depth 70 ft PMC 20.25.020(3) Minimum frontage 15 ft PMC 20.25.020(10) |
| Binding site plan PMC 19.10.060(2) | A | 2 or more PMC 19.04.020 | — | Minimum lot size 2,400 sq ft PMC 20.25.020(1) Minimum lot width 30 ft PMC 20.25.020(2) Minimum lot depth 70 ft PMC 20.25.020(3) Minimum frontage 15 ft PMC 20.25.020(10) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot is within a manufactured/mobile home park established prior to July 1, 2005
- Any of these is true:
- Lot area is at least 23,958 sf
- All of these are true:
- Project uses the RM bonus density menu options of PMC 20.25.0235
- Lot area is at least 17,114 sf
- Main dwelling units on the lot is at most 50
- Main dwelling units on the lot is more than 50
- No other residential treatment facility is within 1,000 feet
- None of these is true:
- Project uses the RM bonus density menu options of PMC 20.25.0235
- Project uses the RM bonus density menu options of PMC 20.25.0235
- All of these are true:
- Residents is at least 7
- Residents is at most 8
- All of these are true:
- Residents is at least 5
- Residents is at most 6
- Project uses the traditional street system organization option of PMC 20.26.200(3)
- None of these is true:
- Project uses the traditional street system organization option of PMC 20.26.200(3)
- Any of these is true:
- The portion of the building is within 100 feet of an RS single-family zone district
- Where the project puts parking (covering at least 60% of the building footprint) to get RM bonus height is none
- All of these are true:
- Where the project puts parking (covering at least 60% of the building footprint) to get RM bonus height is under_building
- The portion of the building is within 100 feet of an RS single-family zone district
- All of these are true:
- Where the project puts parking (covering at least 60% of the building footprint) to get RM bonus height is underground
- The portion of the building is within 100 feet of an RS single-family zone district
- Lot is within the downtown planned action area
- None of these is true:
- Lot is within the downtown planned action area
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The parent lot was itself created through a residential lot split