Sign in

CG · General commercial zone

Puyallup, WA · PMC 20.30 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, multiple-family——
Home✓1 ADUH1
Home✓1 ADUH1
—
Boardinghome————
Home✓ ADUH
Residential care facility————
Home✓ ADUH
Transitional housing————
Home✓ ADUH
Permanent supportive housing————
Home✓ ADUH
Emergency housing, scattered site units————
Home✓ ADUH
Emergency shelter, scattered site units————
Home✓ ADUH
Emergency housing, congregate————
HomeH ADUH
Emergency shelter, congregate————
HomeH ADUH
Co-living————
Home✓1 ADUH1

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot width50 ft PMC 20.30.030(2)
Minimum lot depth100 ft PMC 20.30.030(3)
Minimum frontage35 ft PMC 20.30.030(8)
Maximum residentsNot set PMC 20.30.030
6 persons PMC 20.30.010(16)
for Boardinghome (group living); Residential care facility (group living)2
8 persons PMC 20.30.010(16)
for Boardinghome (group living)3
4 persons PMC 20.30.010(17)
for Residential care facility (group living)
30 persons PMC 20.72.050(5)
for Emergency housing, congregate (group living); Emergency shelter, congregate (group living)

3. Building standards

StandardValueExceptions
Front setback12 ft PMC 20.30.037(2)(c)
Maximum front setback20 ft PMC 20.30.037(2)(c)(i)
Side setback0 ft PMC 20.30.030(6)
Street side setback12 ft PMC 20.30.037(2)(c)
Rear setback0 ft PMC 20.30.030(5)
Maximum height
  • 75 ft4 PMC 20.30.030(12); 20.30.032(4); 20.30.032(4)(a)(i)-(iv)
  • 50 ft5 PMC 20.30.030(11); 20.30.032(4)
Maximum lot coverage75% PMC 20.30.030(10)
Maximum floor area ratio4 PMC 20.30.030(13)
Minimum parking2 spaces per unit PMC 20.55.010(10)
  • 0 spaces per sleeping unit6 PMC 20.29.035(1)
  • 0.25 spaces per sleeping unit7 PMC 20.29.035(2)
for Co-living (group living)1
Maximum unit sizeNot set PMC 20.30.030
300 sq ft PMC 20.29.020(1)(a)
for Co-living (group living)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit PMC 20.30.022

Building

StandardValueExceptions
Front setback12 ft PMC 20.30.037(2)(c)
Side setback0 ft PMC 20.30.030(6)
Rear setback0 ft PMC 20.30.030(5)
Maximum height
  • 75 ft4 PMC 20.30.030(12); 20.30.032(4); 20.30.032(4)(a)(i)-(iv)
  • 50 ft5 PMC 20.30.030(11); 20.30.032(4)
Minimum parking
  • 0 spaces per unit6 PMC 20.55.010(11)(a)
  • 1 space per unit8 PMC 20.55.010(11)(b)
  • 1 space per unit9 PMC 20.55.010(11)(c)
  • 2 spaces per unit10 PMC 20.55.010(11)(c)
Attached to the main houseNot required PMC 20.30.022

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short PMC 19.07.100(1) A up to 9 PMC 19.07.020 —
Minimum lot width
50 ft PMC 20.30.030(2)
Minimum lot depth
100 ft PMC 20.30.030(3)
Minimum frontage
35 ft PMC 20.30.030(8)
Subdivision, major PMC 19.08.120 H 10 or more PMC 19.08.010 —
Minimum lot width
50 ft PMC 20.30.030(2)
Minimum lot depth
100 ft PMC 20.30.030(3)
Minimum frontage
35 ft PMC 20.30.030(8)
Unit lot subdivision PMC 19.11.020(1)(a) A 2 or more PMC 19.04.210 —
Minimum lot size
Unit lot(s) are not subject to PMC Title 20 dimensional standards of the applicable zoning district but shall meet the applicable building fire separation standards, fire access, adequacy of emergency vehicle access and fire protection water system standards. PMC 19.11.030(1)(d)
Binding site plan PMC 19.10.060(2) A 2 or more PMC 19.04.020 —
Minimum lot width
50 ft PMC 20.30.030(2)
Minimum lot depth
100 ft PMC 20.30.030(3)
Minimum frontage
35 ft PMC 20.30.030(8)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Multiple-family use is accessory to a principal use in a mixed use development and in the same structure
    • Multiple-family use occupies no more than 50% of the structure's gross floor area and no more than 25% of the first story building wall facing a public street
  2. All of these are true:
    • Residents is at least 5
    • Residents is at most 6
  3. All of these are true:
    • Residents is at least 7
    • Residents is at most 8
  4. All of these are true:
    • Project uses the zone's building height bonus provisions
    • Building is located 500 feet or further from any residentially zoned property
  5. Not all of these are true:
    • Project uses the zone's building height bonus provisions
    • Building is located 500 feet or further from any residentially zoned property
  6. Lot is within one-half mile walking distance of a major transit stop
  7. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  8. All of these are true:
    • Lot area is less than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  9. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one ADU is at most 1
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  10. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one ADU is at least 2
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop