CBD · Central business district zone
Puyallup, WA · PMC 20.30 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, multiple-family | — | — | — | ||
| Boardinghome | — | — | — | — | Home✓ ADU— |
| Residential care facility | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Emergency housing, scattered site units | — | — | — | — | Home✓ ADU— |
| Emergency shelter, scattered site units | — | — | — | — | Home✓ ADU— |
| Emergency housing, congregate | — | — | — | — | HomeH ADU— |
| Emergency shelter, congregate | — | — | — | — | HomeH ADU— |
| Co-living | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot width | 30 ft PMC 20.30.030(2) | |
| Minimum lot depth | 70 ft PMC 20.30.030(3) | |
| Minimum frontage | 30 ft PMC 20.30.030(8) | |
| Maximum density | No limit PMC 20.30.025 | |
| Maximum residents | Not set PMC 20.30.030 | 6 persons PMC 20.30.010(16)
8 persons PMC 20.30.010(16)
for Boardinghome (group living)3 4 persons PMC 20.30.010(17)
for Residential care facility (group living) 30 persons PMC 20.72.050(5)
for Emergency housing, congregate (group living); Emergency shelter, congregate (group living) |
| Maximum sleeping units | Not set PMC 20.30.030 | No limit PMC 20.30.025
for Co-living (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft PMC 20.30.031 | |
| Maximum front setback | Building shall be located on the front setback line (i.e., a zero-foot front yard setback) but may be set back far enough to incorporate one or a combination of the following site amenities: PMC 20.30.031 | |
| Side setback | 0 ft PMC 20.30.030(6) | |
| Street side setback | 0 ft PMC 20.30.030(7) | |
| Rear setback | 0 ft PMC 20.30.030(5) | |
| Maximum height | ||
| Maximum lot coverage | 100% PMC 20.30.030(10) | |
| Maximum floor area ratio | 2.75 PMC 20.30.030(13) | |
| Minimum parking | ||
| Maximum unit size | Not set PMC 20.30.030 | 300 sq ft PMC 20.29.020(1)(a)
for Co-living (group living)1 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short PMC 19.07.100(1) | A | up to 9 PMC 19.07.020 | — | Minimum lot width 30 ft PMC 20.30.030(2) Minimum lot depth 70 ft PMC 20.30.030(3) Minimum frontage 30 ft PMC 20.30.030(8) |
| Subdivision, major PMC 19.08.120 | H | 10 or more PMC 19.08.010 | — | Minimum lot width 30 ft PMC 20.30.030(2) Minimum lot depth 70 ft PMC 20.30.030(3) Minimum frontage 30 ft PMC 20.30.030(8) |
| Unit lot subdivision PMC 19.11.020(1)(a) | A | 2 or more PMC 19.04.210 | — | Minimum lot size Unit lot(s) are not subject to PMC Title 20 dimensional standards of the applicable zoning district but shall meet the applicable building fire separation standards, fire access, adequacy of emergency vehicle access and fire protection water system standards. PMC 19.11.030(1)(d) |
| Binding site plan PMC 19.10.060(2) | A | 2 or more PMC 19.04.020 | — | Minimum lot width 30 ft PMC 20.30.030(2) Minimum lot depth 70 ft PMC 20.30.030(3) Minimum frontage 30 ft PMC 20.30.030(8) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Any of these is true:
- None of these is true:
- Lot fronts on Meridian Street or on an intersecting side street within one block of Meridian Street
- At least 75 percent of the sidewalk level frontage consists of, or is adaptable to, commercial space
- None of these is true:
- All of these are true:
- Residents is at least 5
- Residents is at most 6
- All of these are true:
- Residents is at least 7
- Residents is at most 8
- All of these are true:
- Project uses the zone's building height bonus provisions
- Building does not directly abut residentially zoned property outside the downtown planned action area nor property listed on a National Historic Register
- Not all of these are true:
- Project uses the zone's building height bonus provisions
- Building does not directly abut residentially zoned property outside the downtown planned action area nor property listed on a National Historic Register
- Lot is within the downtown planned action area
- None of these is true:
- Lot is within the downtown planned action area
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-half mile walking distance of a major transit stop