Sign in

CB · Community business zone

Puyallup, WA · PMC 20.30 · Official code

By right: 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, multiple-family——
Home✓1 ADUH1
Home✓1 ADUH1
—
Retirement apartments———
Home✓ ADUH
—
Senior housing complex———
Home✓ ADUH
—
Boardinghome————
Home✓ ADUH
Residential care facility————
Home✓ ADUH
Transitional housing————
Home✓ ADUH
Permanent supportive housing————
Home✓ ADUH
Emergency housing, scattered site units————
Home✓ ADUH
Emergency shelter, scattered site units————
Home✓ ADUH
Emergency housing, congregate————
HomeH ADUH
Emergency shelter, congregate————
HomeH ADUH
Co-living————
Home✓1 ADUH1

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot width75 ft PMC 20.30.030(2)
Minimum lot depth100 ft PMC 20.30.030(3)
Minimum frontage35 ft PMC 20.30.030(8)
Maximum density
  • No limit2 PMC 20.25.022(2)
  • 16 units per acre, a fraction of 0.5 or more rounds up3 PMC 20.25.022(2); 20.30.026(2)(d)
  • 22 units per acre, a fraction of 0.5 or more rounds up4 PMC 20.25.022(2); 20.25.0235; 20.30.026(2)(d)
Maximum residentsNot set PMC 20.30.030
6 persons PMC 20.30.010(16)
for Boardinghome (group living); Residential care facility (group living)5
8 persons PMC 20.30.010(16)
for Boardinghome (group living)6
4 persons PMC 20.30.010(17)
for Residential care facility (group living)
30 persons PMC 20.72.050(5)
for Emergency housing, congregate (group living); Emergency shelter, congregate (group living)
Maximum sleeping unitsNot set PMC 20.30.030
  • No limit2 PMC 20.25.022(2)
  • 4 × ((16 × lot area) ÷ 43,560, rounded) sleeping units3 PMC 20.25.022(2); 20.30.026(2)(d); 20.29.025
  • 4 × ((22 × lot area) ÷ 43,560, rounded) sleeping units4 PMC 20.25.022(2); 20.25.0235; 20.30.026(2)(d); 20.29.025
for Co-living (group living)1

3. Building standards

StandardValueExceptions
Front setback12 ft PMC 20.30.037(2)(c)
Maximum front setback20 ft PMC 20.30.037(2)(c)(i)
Street side setback12 ft PMC 20.30.037(2)(c)
Rear setback10 ft PMC 20.30.030(5)
Maximum height
  • 75 ft7 PMC 20.30.030(12); 20.30.032(4); 20.30.032(4)(a)(i)-(iv)
  • 50 ft8 PMC 20.30.030(11); 20.30.032(4)
Maximum lot coverage75% PMC 20.30.030(10)
Maximum floor area ratio4 PMC 20.30.030(13)
Minimum parking2 spaces per unit PMC 20.55.010(10)
0.5 spaces per unit PMC 20.55.010(25)
for Retirement apartments (4+ units)
Where ambiguity exists in the application of off-street parking requirements, or where the parking requirements for a use are not specifically defined herein, the parking requirements for such use shall be determined by the planning director or the director's designee and such determination shall be based upon the requirements for the most comparable use specified in this chapter. PMC 20.55.015
for Senior housing complex (4+ units)
  • 0 spaces per sleeping unit9 PMC 20.29.035(1)
  • 0.25 spaces per sleeping unit10 PMC 20.29.035(2)
for Co-living (group living)1
Maximum unit sizeNot set PMC 20.30.030
300 sq ft PMC 20.29.020(1)(a)
for Co-living (group living)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit PMC 20.30.022

Building

StandardValueExceptions
Front setback12 ft PMC 20.30.037(2)(c)
Rear setback10 ft PMC 20.30.030(5)
Maximum height
  • 75 ft7 PMC 20.30.030(12); 20.30.032(4); 20.30.032(4)(a)(i)-(iv)
  • 50 ft8 PMC 20.30.030(11); 20.30.032(4)
Minimum parking
  • 0 spaces per unit9 PMC 20.55.010(11)(a)
  • 1 space per unit11 PMC 20.55.010(11)(b)
  • 1 space per unit12 PMC 20.55.010(11)(c)
  • 2 spaces per unit13 PMC 20.55.010(11)(c)
Attached to the main houseNot required PMC 20.30.022

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short PMC 19.07.100(1) A up to 9 PMC 19.07.020 —
Minimum lot width
75 ft PMC 20.30.030(2)
Minimum lot depth
100 ft PMC 20.30.030(3)
Minimum frontage
35 ft PMC 20.30.030(8)
Subdivision, major PMC 19.08.120 H 10 or more PMC 19.08.010 —
Minimum lot width
75 ft PMC 20.30.030(2)
Minimum lot depth
100 ft PMC 20.30.030(3)
Minimum frontage
35 ft PMC 20.30.030(8)
Unit lot subdivision PMC 19.11.020(1)(a) A 2 or more PMC 19.04.210 —
Minimum lot size
Unit lot(s) are not subject to PMC Title 20 dimensional standards of the applicable zoning district but shall meet the applicable building fire separation standards, fire access, adequacy of emergency vehicle access and fire protection water system standards. PMC 19.11.030(1)(d)
Binding site plan PMC 19.10.060(2) A 2 or more PMC 19.04.020 —
Minimum lot width
75 ft PMC 20.30.030(2)
Minimum lot depth
100 ft PMC 20.30.030(3)
Minimum frontage
35 ft PMC 20.30.030(8)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Multifamily residential use is accessory to a commercial use on the same site
    • Gross floor area of multifamily residential and senior housing uses is no more than 50% of the gross floor area of the commercial uses on the site
  2. Lot is within the downtown planned action area
  3. None of these is true:
    • Lot is within the downtown planned action area
    • Project uses the RM bonus density menu options of PMC 20.25.0235
  4. All of these are true:
    • Project uses the RM bonus density menu options of PMC 20.25.0235
    None of these is true:
    • Lot is within the downtown planned action area
  5. All of these are true:
    • Residents is at least 5
    • Residents is at most 6
  6. All of these are true:
    • Residents is at least 7
    • Residents is at most 8
  7. All of these are true:
    • Project uses the zone's building height bonus provisions
    • Building is located 500 feet or further from any residentially zoned property
  8. Not all of these are true:
    • Project uses the zone's building height bonus provisions
    • Building is located 500 feet or further from any residentially zoned property
  9. Lot is within one-half mile walking distance of a major transit stop
  10. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  11. All of these are true:
    • Lot area is less than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  12. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one ADU is at most 1
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  13. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one ADU is at least 2
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop