Sign in

C-2 · C-2: Viking Avenue

Poulsbo, WA · PMC 18.80 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mixed-use structure
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Planned mixed-use developments (PMUD)—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Dwelling, multifamily—
Home✓3 ADU—
Home✓3 ADU—
Home✓3 ADU—
—
Adult family home————
Home✓4 ADU—
Nursing home————
HomeA ADU—
Residential care facility————
HomeA ADU—
Assisted living————
HomeA ADU—
Congregate care senior housing————
HomeA ADU—
Emergency shelter————
HomeA5 ADU—
Emergency housing————
HomeA ADU—
Permanent supportive housing————
HomeA ADU—
Transitional housing————
HomeA6 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit PMC 18.80.040(A)
Maximum residentsNot set PMC 18.80.040
6 persons PMC 18.40.030
for Adult family home (group living)4
40 persons PMC 18.80.080(Q)(2)
for Emergency shelter (group living)5

3. Building standards

StandardValueExceptions
Front setback10 ft PMC 18.80.040(A)
Side setback
  • 15 ft7 PMC 18.80.040(A); 18.80.070(C)(3)
  • 0 ft8 PMC 18.80.070(C)(3)
  • 5 ft9 PMC 18.80.040(A)
Rear setback
  • 15 ft7 PMC 18.80.040(A); 18.80.070(C)(3)
  • 5 ft8 PMC 18.80.070(C)(3)
  • 10 ft9 PMC 18.80.040(A)
Maximum height
  • 55 ft10 PMC 18.80.040(C)(2); 18.80.070(C)(1)(a)-(b)
  • 35 + 10 ft11 PMC 18.80.040(C); 18.80.040(C)(1); 18.310.010(C)
  • 35 ft12 PMC 18.80.040(C); 18.80.070(D)(4)
Maximum lot coverage
  • 80%13 PMC 18.80.070(C)(2)
  • 50%14 PMC 18.80.040(A)
Minimum parking
  • 1.25 + (1 ÷ 10) spaces per unit15 PMC 18.80.110(A)(12)(e); 18.80.110(A)(12)(d)
  • 1 + (1 ÷ 10) spaces per unit16 PMC 18.80.110(A)(12)(b); 18.80.110(A)(12)(d)
  • 2 + (1 ÷ 10) spaces per unit17 PMC 18.80.110(A)(12)(c); 18.80.110(A)(12)(d)
Other uses not specifically listed shall furnish parking as required by the planning director based upon the most analogous use. PMC 18.80.110(A)(16)
for Adult family home (group living)4; Nursing home (group living)
(beds in the project ÷ 4) + (employees on the largest shift ÷ 2) spaces PMC 18.80.110(A)(12)(f)
for Residential care facility (group living); Assisted living (group living); Congregate care senior housing (group living)
(beds in the project ÷ 4) + employees on the largest shift spaces PMC 18.80.110(A)(12)(g)
for Emergency shelter (group living)5; Emergency housing (group living); Permanent supportive housing (group living); Transitional housing (group living)6
Maximum lot sizeNo limit PMC 18.80.040(A)
Minimum open space
  • 15%13 PMC 18.80.070(C)(4)
  • 20%14 PMC 18.80.060(B)(1)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Binding site plan PMC 17.50.030; 17.50.020(A) A — Not set PMC 18.80.040(A)
Minimum lot size
No limit PMC 18.80.040(A); 17.80.010(D)
Short subdivision PMC 17.40.020(A) A up to 4 PMC 17.40.020(A); 17.20.010 Not set PMC 18.80.040(A)
Minimum lot size
No limit PMC 18.80.040(A); 17.40.020(B); 17.60.020(B)
Subdivision (preliminary subdivision) PMC 17.60.020(A) H 5 or more PMC 17.20.010 Not set PMC 18.80.040(A)
Minimum lot size
No limit PMC 18.80.040(A); 17.40.020(B); 17.60.020(B)
Unit lot subdivision PMC 17.65.060; 17.65.020(A)Only for: Dwelling, multifamily, Planned mixed-use developments (PMUD), Mixed-use structure A — Not set PMC 18.80.040(A); 17.65.020(D)
Minimum lot size
No limit PMC 17.65.020(B)
Maximum units per lot
1 unit PMC 17.65.020(D)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Residential units are in a mixed-use structure that contains at least one other complementary, integrated or mutually supporting use (such as offices, retail or services)
  2. Project is a planned mixed-use development in which residential and commercial uses each make up at least 20% of the buildings' gross square footage
  3. All of these are true:
    • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
    • The stand-alone residential structure is located in the interior of the development
  4. The lot has an existing residential use
  5. None of these is true:
    • All of these are true:
      • The emergency shelter is continuously operating (not a temporary response to a natural disaster or similar acute emergency)
      • Lot is within half a mile of a continuously operating emergency housing facility
    • Lot is within half a mile of a property that contains permanent supportive housing
    • Lot is within half a mile of a property that contains transitional housing
  6. None of these is true:
    • Lot is within half a mile of a property that contains permanent supportive housing
    • Lot is within half a mile of a property that contains transitional housing
    • Lot is within half a mile of emergency housing
    • Lot is within half a mile of an emergency shelter
  7. The lot line is adjacent to an R zoning district; the larger setback applies on that side
  8. All of these are true:
    • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
    None of these is true:
    • The lot line is adjacent to an R zoning district; the larger setback applies on that side
  9. None of these is true:
    • The lot line is adjacent to an R zoning district; the larger setback applies on that side
    • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
  10. All of these are true:
    • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
    None of these is true:
    • The building or building segment is within twenty-five feet of an R zone
  11. All of these are true:
    • The structure includes underbuilding parking (height bonus of 10 feet)
    • Not all of these are true:
      • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
      • None of these is true:
        • The building or building segment is within twenty-five feet of an R zone
  12. All of these are true:
    • Not all of these are true:
      • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
      • None of these is true:
        • The building or building segment is within twenty-five feet of an R zone
    None of these is true:
    • The structure includes underbuilding parking (height bonus of 10 feet)
  13. Project uses the C-2 infill and redevelopment alternative development standards through site plan review
  14. None of these is true:
    • Project uses the C-2 infill and redevelopment alternative development standards through site plan review
  15. Residential units are restricted to use for seniors (sixty-five years and older)
  16. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Residential units are restricted to use for seniors (sixty-five years and older)
  17. All of these are true:
    • Bedrooms in one unit is at least 2
    None of these is true:
    • Residential units are restricted to use for seniors (sixty-five years and older)