CH · Commercial heavy (CH)
Port Orchard, WA · POMC 20.35 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Indoor emergency housing | — | — | — | — | HomeH ADU— |
| Indoor emergency shelter | — | — | — | — | HomeH ADU— |
| Permanent supportive housing | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft POMC 20.35.070(5)(a) | |
| Side setback | 20 ft POMC 20.35.070(5)(c) | |
| Street side setback | 20 ft POMC 20.35.070(5)(b) | |
| Rear setback | 20 ft POMC 20.35.070(5)(d) | |
| Maximum height | ||
| Maximum stories | ||
| Maximum impervious surface | 70% POMC 20.35.070(4) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision POMC 20.86.020; 20.22.040(5) | A | up to 9 POMC 20.86.010; 20.12.200 | — | Minimum lot size 7,000 sq ft POMC 20.35.070(3)(a)(ii) Minimum lot width 70 ft POMC 20.35.070(3)(b)(ii) Minimum lot depth Not set POMC 20.35.070(3) Maximum units per lot Not set POMC 20.35.070(3) |
| Subdivision POMC 20.88.020(1); 20.22.050(5) | H | 10 or more POMC 20.12.200 | — | Minimum lot size 7,000 sq ft POMC 20.35.070(3)(a)(ii) Minimum lot width 70 ft POMC 20.35.070(3)(b)(ii) Minimum lot depth Not set POMC 20.35.070(3) Maximum units per lot Not set POMC 20.35.070(3) |
| Binding site plan POMC 20.94.050(1); 20.22.040(5) | A | Minimum lots Not set POMC 20.94.020 |
— | Minimum lot size 7,000 sq ft POMC 20.35.070(3)(a)(ii) Minimum lot width 70 ft POMC 20.35.070(3)(b)(ii) Minimum lot depth Not set POMC 20.35.070(3) Maximum units per lot Not set POMC 20.94.020 |
| Boundary line adjustment POMC 20.84.020; 20.84.040(2)(b) | A | Maximum lots A boundary line adjustment shall not be used to subdivide land, i.e., it shall not create any new or additional lot, tract or parcel. POMC 20.84.010 |
— | Maximum units per lot Not set POMC 20.84.040 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The lot is a flag lot: a lot with less length of property on a street than is normally required, generally intended to make deeper property accessible
- None of these is true:
- The lot is a flag lot: a lot with less length of property on a street than is normally required, generally intended to make deeper property accessible
- The lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- All of these are true:
- The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070
- The project buys Kitsap County development rights to use the TDR height bonus
- The lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- All of these are true:
- Not all of these are true:
- The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070
- The project buys Kitsap County development rights to use the TDR height bonus
- The lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- Not all of these are true:
- All of these are true:
- The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070
- The project buys Kitsap County development rights to use the TDR height bonus
- Not all of these are true: The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070; The project buys Kitsap County development rights to use the TDR height bonus