CC · Commercial corridor (CC)
Port Orchard, WA · POMC 20.35 · Official code
By right: 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Shopfront house | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Mixed use shopfront | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| General building | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Live-work | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Co-living | — | — | — | — | Home✓ ADU— |
| All group living (9 or more residents) | — | — | — | — | Home✓ ADU— |
| Indoor emergency housing | — | — | — | — | HomeH ADU— |
| Indoor emergency shelter | — | — | — | — | HomeH ADU— |
| Permanent supportive housing | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 5,000 sq ft POMC 20.35.060(3)(a)(ii) | 1,000 sq ft POMC 20.35.060(3)(a)(i)
for Live-work (3, 4+ units) |
| Minimum lot width | 50 ft POMC 20.35.060(3)(b)(ii) | 25 ft POMC 20.35.060(3)(b)(i)
for Live-work (3, 4+ units) |
| Minimum frontage | ||
| Minimum development size | Not set POMC 20.35.060(3) | 4,000 sq ft POMC 20.32.110(1)(a)
for Live-work (3, 4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft POMC 20.35.060(5)(a) | |
| Maximum front setback | 50 ft POMC 20.35.060(5)(a) | |
| Side setback | 10 ft POMC 20.35.060(5)(c) | |
| Street side setback | 0 ft POMC 20.35.060(5)(b) | |
| Rear setback | 10 ft POMC 20.35.060(5)(d) | |
| Maximum height | ||
| Maximum stories | 3 stories POMC 20.32.120(2)(a)
for Shopfront house (2, 3, 4+ units); Live-work (3, 4+ units) | |
| Maximum impervious surface | 70% POMC 20.35.060(4) | |
| Minimum parking | for Co-living (group living) Not set POMC 20.124.140(1)
for All group living (9 or more residents) (group living); Indoor emergency housing (group living); Indoor emergency shelter (group living); Permanent supportive housing (group living); Transitional housing (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision POMC 20.86.020; 20.22.040(5) | A | up to 9 POMC 20.86.010; 20.12.200 | — | Minimum lot size 1,000 sq ft POMC 20.35.060(3)(a)(i) Minimum lot width 25 ft POMC 20.35.060(3)(b)(i) Minimum lot depth Not set POMC 20.35.060(3) Maximum units per lot Not set POMC 20.35.060(3) |
| Subdivision POMC 20.88.020(1); 20.22.050(5) | H | 10 or more POMC 20.12.200 | — | Minimum lot size 1,000 sq ft POMC 20.35.060(3)(a)(i) Minimum lot width 25 ft POMC 20.35.060(3)(b)(i) Minimum lot depth Not set POMC 20.35.060(3) Maximum units per lot Not set POMC 20.35.060(3) |
| Binding site plan POMC 20.94.050(1); 20.22.040(5) | A | Minimum lots Not set POMC 20.94.020 |
— | Minimum lot size 1,000 sq ft POMC 20.35.060(3)(a)(i) Minimum lot width 25 ft POMC 20.35.060(3)(b)(i) Minimum lot depth Not set POMC 20.35.060(3) Maximum units per lot Not set POMC 20.94.020 |
| Boundary line adjustment POMC 20.84.020; 20.84.040(2)(b) | A | Maximum lots A boundary line adjustment shall not be used to subdivide land, i.e., it shall not create any new or additional lot, tract or parcel. POMC 20.84.010 |
— | Maximum units per lot Not set POMC 20.84.040 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The lot is a flag lot: a lot with less length of property on a street than is normally required, generally intended to make deeper property accessible
- None of these is true:
- The lot is a flag lot: a lot with less length of property on a street than is normally required, generally intended to make deeper property accessible
- The lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- All of these are true:
- The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070
- The project buys Kitsap County development rights to use the TDR height bonus
- The lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- All of these are true:
- Not all of these are true:
- The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070
- The project buys Kitsap County development rights to use the TDR height bonus
- The lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- Not all of these are true:
- It is not true that the lot is within the view protection overlay district (VPOD) shown on Figure 3 of POMC 20.38.800
- All of these are true:
- The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070
- The project buys Kitsap County development rights to use the TDR height bonus
- Not all of these are true: The lot is within an eligible TDR receiving area shown on the map in POMC 20.41.070; The project buys Kitsap County development rights to use the TDR height bonus
- Any of these is true:
- The dwelling units are affordable housing
- The dwelling units are senior housing
- Floor area of one unit is at most 1,200
- All of these are true:
- Floor area of one unit is more than 1,200
- The dwelling units are affordable housing
- The dwelling units are senior housing
- The site is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535(11)
- None of these is true:
- The site is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535(11)