Sign in

ROC · Residential/Office-Civic

Pierce County, WA · PCC 18A.10.080(C)(2)(b) · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Single-Family Housing
Home✓ ADU✓1
————
Duplexes—
Home✓ ADU✓1
———
Attached Single-Family Housing—
Home✓ ADU✓1
Home✓ ADU✓1
Home✓ ADU✓1
—
Middle Housing——
Home✓ ADU✓1
Home✓ ADU✓1
—
Multi-Family Housing Level 1———
Home✓ ADU—
—
Multi-Family Housing Level 2———
Home✓2 ADU—
—
Senior Housing Level 2———
Home✓ ADU—
—
Cottage Housing———
Home✓ ADU—
—
Group Home————
Home✓3 H4 ADU—
Residential Care Facility Level 1————
Home✓ ADU—
Residential Care Facility Level 2————
Home✓ ADU—
Senior Housing Level 1————
Home✓ ADU—
Boarding and Rooming Houses————
Home✓ ADU—
Congregate Housing————
Home✓ ADU—
Shared Housing Villages————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set PCC 18A.33.210
5 units PCC 18A.33.210(G)
for Middle Housing (4+ units)
16 units PCC 18A.33.210(G)
for Cottage Housing (4+ units)
Minimum unitsNot set PCC 18A.33.210
6 units PCC 18A.33.210(D)
for Multi-Family Housing Level 1 (4+ units)
Minimum lot sizeNot set PCC Table 18A.15.020-1
  • In any zone that permits a single-family dwelling unit, a single-family dwelling unit and permitted accessory structures may be constructed or enlarged on a lot which cannot satisfy the lot size and/or density requirements of the zone where the lot was legally created.5 PCC 18A.15.010(B)
  • Not set6 PCC Table 18A.15.020-1
for Detached Single-Family Housing (1 unit)
Minimum density
  • 0 units per acre, on the net lot area7 PCC 18A.15.020(B)(2)(a)
  • 6 × 0.5 units per acre, on the net lot area8 PCC Table 18A.15.020-1; 18A.15.020(A)(9)
  • 6 units per acre, on the net lot area9 PCC Table 18A.15.020-1
Not set PCC 18A.15.020
for Group Home (group living)4; Group Home (group living)3; Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living); Boarding and Rooming Houses (group living); Congregate Housing (group living); Shared Housing Villages (group living)
Maximum density
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • In any zone that permits a single-family dwelling unit, a single-family dwelling unit and permitted accessory structures may be constructed or enlarged on a lot which cannot satisfy the lot size and/or density requirements of the zone where the lot was legally created.22 PCC 18A.15.010(B)
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area24 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area25 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area26 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area27 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area28 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area29 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area30 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
for Detached Single-Family Housing (1 unit)
10 × 2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area PCC Table 18A.15.020-1; PCC 18A.15.020(E)(1)(i)
for Cottage Housing (4+ units)
Not set PCC 18A.15.020
for Group Home (group living)4; Group Home (group living)3; Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living); Boarding and Rooming Houses (group living); Congregate Housing (group living); Shared Housing Villages (group living)
Maximum sleeping unitsNot set PCC 18A.33.210
  • 4 × ((10 × lot area minus critical areas and buffers) ÷ 43,560, rounded) sleeping units31 PCC Table 18A.15.020-1; PCC 18A.15.020(A)(8)
  • 4 × ((12 × lot area minus critical areas and buffers) ÷ 43,560, rounded) sleeping units32 PCC Table 18A.15.020-1; PCC 18A.15.020(A)(8); PCC 18A.15.020(D)
for Boarding and Rooming Houses (group living); Congregate Housing (group living); Shared Housing Villages (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • The height and setbacks for buildings in HRD, ROC, and NC zone classifications in the South Hill Community Plan area shall be limited to the maximum height and minimum setbacks of any immediately adjacent residential zone classification, pursuant to PCC 18J.50.080.A.34 PCC 18A.15.040(B)(1)(d)
  • Averaging may be used to reduce a front setback requirement when a principal building has been established on an adjacent lot within the required yard. Averaging shall be calculated by adding the existing front setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front setback of the adjacent developed lot with the minimum front setback of the zone in which the construction is proposed and dividing that figure by two.35 PCC 18A.15.040(B)(3)(b); 18A.15.040(B)(3)(b)(1); 18A.15.040(B)(3)(b)(2)
  • 25 ft36 PCC Table 18A.15.040-1
  • 15 ft37 PCC Table 18A.15.040-1
Maximum front setbackNot read PCC Title 18J
Side setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • The height and setbacks for buildings in HRD, ROC, and NC zone classifications in the South Hill Community Plan area shall be limited to the maximum height and minimum setbacks of any immediately adjacent residential zone classification, pursuant to PCC 18J.50.080.A.34 PCC 18A.15.040(B)(1)(d)
  • 0 ft38 PCC Table 18A.15.040-1
Street side setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • The height and setbacks for buildings in HRD, ROC, and NC zone classifications in the South Hill Community Plan area shall be limited to the maximum height and minimum setbacks of any immediately adjacent residential zone classification, pursuant to PCC 18J.50.080.A.34 PCC 18A.15.040(B)(1)(d)
  • 25 ft39 PCC 18A.15.040(A)(2); PCC Table 18A.15.040-1
  • 15 ft40 PCC 18A.15.040(A)(2)
Rear setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • The height and setbacks for buildings in HRD, ROC, and NC zone classifications in the South Hill Community Plan area shall be limited to the maximum height and minimum setbacks of any immediately adjacent residential zone classification, pursuant to PCC 18J.50.080.A.34 PCC 18A.15.040(B)(1)(d)
  • 0 ft38 PCC Table 18A.15.040-1
Maximum height
  • The height and setbacks for buildings in HRD, ROC, and NC zone classifications in the South Hill Community Plan area shall be limited to the maximum height and minimum setbacks of any immediately adjacent residential zone classification, pursuant to PCC 18J.50.080.A.41 PCC 18A.15.040(B)(1)(d)
  • 45 ft42 PCC Table 18A.15.040-3
Minimum parking2 spaces per unit PCC Table 18A.35.040-1
  • 1.5 spaces per unit43 PCC Table 18A.35.040-1
  • 2 spaces per unit44 PCC Table 18A.35.040-1
  • 2.25 spaces per unit45 PCC Table 18A.35.040-1
for Multi-Family Housing Level 1 (4+ units); Multi-Family Housing Level 2 (4+ units)2
  • 0 spaces per unit46 PCC Table 18A.35.040-1 note (3)
  • 0.5 × bedrooms in the whole project spaces47 PCC Table 18A.35.040-1
for Senior Housing Level 2 (4+ units); Group Home (group living)4; Group Home (group living)3; Senior Housing Level 1 (group living)
  • 1 space per unit48 PCC Table 18A.35.040-1
  • 1.5 spaces per unit49 PCC Table 18A.35.040-1
  • 1.5 spaces per unit50 PCC Table 18A.35.040-1
for Cottage Housing (4+ units)
(beds in the project ÷ 4) + (employees on the largest shift ÷ 2) spaces PCC Table 18A.35.040-1
for Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living)
  • 0 spaces per sleeping unit46 PCC Table 18A.35.040-1 note (3)
  • 0.25 spaces per sleeping unit47 PCC Table 18A.35.040-1
for Boarding and Rooming Houses (group living); Congregate Housing (group living); Shared Housing Villages (group living)
Maximum unit size
  • 1,400 sq ft51 PCC 18A.15.050(B)(16)
  • Not set52 PCC 18A.33.210
  • 1,400 sq ft51 PCC 18A.15.050(B)(16)
  • Not read52 PCC Title 18J
for Cottage Housing (4+ units)
Not set PCC 18A.33.210
for Group Home (group living)4; Group Home (group living)3; Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living); Boarding and Rooming Houses (group living); Congregate Housing (group living); Shared Housing Villages (group living)
Minimum open spaceNot read PCC Title 18J
Maximum units per buildingNot set PCC 18A.33.210
2 units PCC 18A.33.210(G)
for Duplexes (2 units)
5 units PCC 18A.33.210(G)
for Middle Housing (3, 4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units PCC 18A.37.120(A)(1)

Building

StandardValueExceptions
Front setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Detached ADUs shall be no closer to the front lot line than the closest point to the front lot line of the principal structure, unless the ADU was created by the conversion of a pre-existing structure into the ADU.53 PCC 18A.37.120(C)(1)
  • 25 ft54 PCC 18A.37.120(A)(4); Table 18A.15.040-1; 18A.37.120(C)(2)(c)
  • 15 ft55 PCC 18A.37.120(A)(4); Table 18A.15.040-1; 18A.37.120(C)(2)(c)
Side setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Conversion of an existing detached structure to an ADU shall be permitted within the side or rear yard setback when the structure is located within the UGA.56 PCC 18A.37.120(A)(6)
  • 0 ft57 PCC Table 18A.15.040-1
Rear setback
  • 5 ft33 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Conversion of an existing detached structure to an ADU shall be permitted within the side or rear yard setback when the structure is located within the UGA.56 PCC 18A.37.120(A)(6)
  • 0 ft57 PCC Table 18A.15.040-1
Maximum height45 ft PCC 18A.37.120(A)(5); Table 18A.15.040-3
Minimum parking
  • 0 spaces per unit46 PCC 18A.37.120(E)(1)(a); Table 18A.35.040-1 note (3)
  • 1 space per unit47 PCC Table 18A.35.040-1; 18A.37.120(E)(1)(b)
Maximum unit size1,000 sq ft PCC 18A.37.120(B)
Attached to the main houseNot required PCC 18A.37.120(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision PCC 18F.40.020 ✓ —
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum density
  • 0 units per acre, on the net lot area7 PCC 18A.15.020(B)(2)(a)
  • 6 × 0.5 units per acre, on the net lot area8 PCC Table 18A.15.020-1; 18A.15.020(A)(9)
  • 6 units per acre, on the net lot area9 PCC Table 18A.15.020-1
Minimum lot size
Not set PCC Table 18A.15.020-1
Short subdivision PCC 18F.50.040(E) A —
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum density
  • 0 units per acre, on the net lot area7 PCC 18A.15.020(B)(2)(a)
  • 6 × 0.5 units per acre, on the net lot area8 PCC Table 18A.15.020-1; 18A.15.020(A)(9)
  • 6 units per acre, on the net lot area9 PCC Table 18A.15.020-1
Minimum lot size
Not set PCC Table 18A.15.020-1
Unit Lot Subdivision PCC 18F.40.100Only for: Detached Single-Family Housing, Duplexes, Attached Single-Family Housing, Cottage Housing ✓ —
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum lot size
Not set PCC 18F.40.100(D)(1)
Unit Lot Subdivision PCC 18F.50.040(E); 18F.50.070Only for: Detached Single-Family Housing, Duplexes, Attached Single-Family Housing, Cottage Housing A —
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum lot size
Not set PCC 18F.50.070(D)(1)
Infill Lot Creation PCC 18A.15.050(B)(1) ✓ —
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum lot size
Not set PCC 18A.15.050(B)(5)
Maximum lot size
Not set PCC 18A.15.050(B)(9)
Binding Site Plan PCC 18F.60.030(B); 18F.60.030(D) A58 —
  • the smallest of 1.2 × 12, 12 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area10 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.2 × 12, 12 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area11 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area12 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 10 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area13 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 10 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 12 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 12 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum lot size
Not set PCC 18F.60.030

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
  2. Dwelling units are in a mixed-use building above nonresidential activity on the first floor
  3. The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
  4. None of these is true:
    • The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
  5. All of these are true:
    • The lot was legally created
    • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
  6. Not all of these are true:
    • The lot was legally created
    • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
  7. None of these is true:
    • The lot is within 300 feet of a sewer hook-up
  8. All of these are true:
    • The lot is within 300 feet of a sewer hook-up
    • Lot area is less than 43,560 sf
    • The lot contains an existing residential or commercial use
  9. All of these are true:
    • The lot is within 300 feet of a sewer hook-up
    • Not all of these are true:
      • Lot area is less than 43,560 sf
      • The lot contains an existing residential or commercial use
  10. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rental
  11. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_owner_occupied
  12. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  13. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  14. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  15. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  16. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
  17. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
  18. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
  19. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
  20. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rental
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
  21. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_owner_occupied
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
  22. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The lot was legally created
    • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
  23. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  24. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  25. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  26. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  27. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
  28. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
  29. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
  30. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 10
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
  31. None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  32. The project meets the criteria in 18A.15.020.E to exceed Base Density
  33. The lot is a pipestem lot, or its only access is a shared access facility
  34. All of these are true:
    • The building site is immediately adjacent to a residential zone classification
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  35. All of these are true:
    • A principal building has been established on an adjacent lot within the required front yard
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The building site is immediately adjacent to a residential zone classification
    • The adjacent lot has received a reduced setback based upon a discretionary land use approval
  36. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The building site is immediately adjacent to a residential zone classification
  37. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The building site is immediately adjacent to a residential zone classification
    • The front yard abuts an arterial
  38. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The building site is immediately adjacent to a residential zone classification
  39. All of these are true:
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The building site is immediately adjacent to a residential zone classification
  40. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The building site is immediately adjacent to a residential zone classification
    • The front yard abuts an arterial
  41. The building site is immediately adjacent to a residential zone classification
  42. None of these is true:
    • The building site is immediately adjacent to a residential zone classification
  43. Bedrooms in one unit is at most 1
  44. All of these are true:
    • Bedrooms in one unit is at least 2
    • Bedrooms in one unit is less than 3
  45. Bedrooms in one unit is at least 3
  46. Within one-half mile of a major transit stop (RCW 36.70A.681)
  47. None of these is true:
    • Within one-half mile of a major transit stop (RCW 36.70A.681)
  48. All of these are true:
    • Bedrooms in one unit is at most 1
    • Within 1/2 mile of a high-capacity transit route
  49. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Within 1/2 mile of a high-capacity transit route
  50. Bedrooms in one unit is at least 2
  51. The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
  52. None of these is true:
    • The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
  53. All of these are true:
    • The ADU is detached from the principal structure
    • The separation between the principal structure and the ADU is less than 100 linear feet
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
    • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
  54. All of these are true:
    • Not all of these are true:
      • The ADU is detached from the principal structure
      • The separation between the principal structure and the ADU is less than 100 linear feet
      • None of these is true:
        • The ADU is created by converting an existing (pre-existing) detached structure
      • None of these is true:
        • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  55. All of these are true:
    • Not all of these are true:
      • The ADU is detached from the principal structure
      • The separation between the principal structure and the ADU is less than 100 linear feet
      • None of these is true:
        • The ADU is created by converting an existing (pre-existing) detached structure
      • None of these is true:
        • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The front yard abuts an arterial
  56. All of these are true:
    • The ADU is created by converting an existing (pre-existing) detached structure
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  57. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
  58. Any of these is true:
    • The land is divided for sale or lease into lots classified for commercial or industrial uses
    • The division is for the development of condominium units under Chapter 64.34 RCW