Sign in

CE · Community Employment

Pierce County, WA · PCC 18A.10.080(A)(2)(b) · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Senior Housing Level 2———
HomeH1 ADU—
—
Residential Care Facility Level 1————
HomeH1 ADU—
Residential Care Facility Level 2————
HomeH1 ADU—
Senior Housing Level 1————
HomeH1 ADU—
Employee Housing————
HomeH2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum densityNot set PCC 18A.15.020
No limit PCC 18A.33.270(H)
for Employee Housing (group living)2
Maximum densityNot set PCC 18A.15.020
No limit PCC 18A.33.270(H)
for Employee Housing (group living)2

3. Building standards

StandardValueExceptions
Front setback
  • 5 ft3 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Averaging may be used to reduce a front setback requirement when a principal building has been established on an adjacent lot within the required yard. Averaging shall be calculated by adding the existing front setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front setback of the adjacent developed lot with the minimum front setback of the zone in which the construction is proposed and dividing that figure by two.4 PCC 18A.15.040(B)(3)(b); 18A.15.040(B)(3)(b)(1); 18A.15.040(B)(3)(b)(2)
  • 25 ft5 PCC Table 18A.15.040-1
  • 15 ft6 PCC Table 18A.15.040-1
Maximum front setbackNot read PCC Title 18J
Side setback
  • 5 ft3 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft7 PCC Table 18A.15.040-1
Street side setback
  • 5 ft3 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 25 ft8 PCC 18A.15.040(A)(2); PCC Table 18A.15.040-1
  • 15 ft9 PCC 18A.15.040(A)(2)
Rear setback
  • 5 ft3 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft7 PCC Table 18A.15.040-1
Maximum height35 ft PCC Table 18A.15.040-3 note 4
60 ft PCC Table 18A.15.040-3
for Employee Housing (group living)2
Minimum parking
  • 0 spaces per unit10 PCC Table 18A.35.040-1 note (3)
  • 0.5 × bedrooms in the whole project spaces11 PCC Table 18A.35.040-1
(beds in the project ÷ 4) + (employees on the largest shift ÷ 2) spaces PCC Table 18A.35.040-1
for Residential Care Facility Level 1 (group living)1; Residential Care Facility Level 2 (group living)1
1 per 2 units plus 1 per resident manager unit PCC Table 18A.35.040-1
for Employee Housing (group living)2
Maximum unit sizeNot set PCC 18A.33.210
  • 1,400 sq ft12 PCC 18A.15.050(B)(16)
  • Not set13 PCC 18A.33.210
for Senior Housing Level 2 (4+ units)1
Minimum open spaceNot read PCC Title 18J

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision PCC 18F.40.020 ✓ — Not set PCC 18A.15.020
Minimum lot size
Not set PCC Table 18A.15.020-1
Short subdivision PCC 18F.50.040(E) A — Not set PCC 18A.15.020
Minimum lot size
Not set PCC Table 18A.15.020-1
Infill Lot Creation PCC 18A.15.050(B)(1) ✓ — Not set PCC 18A.15.020
Minimum lot size
Not set PCC 18A.15.050(B)(5)
Maximum lot size
Not set PCC 18A.15.050(B)(9)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The community plan area the lot is in (outside means not in an adopted community plan area) is gig_harbor_peninsula
  2. The community plan area the lot is in (outside means not in an adopted community plan area) is parkland_spanaway_midland
  3. The lot is a pipestem lot, or its only access is a shared access facility
  4. All of these are true:
    • A principal building has been established on an adjacent lot within the required front yard
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The adjacent lot has received a reduced setback based upon a discretionary land use approval
  5. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  6. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The front yard abuts an arterial
  7. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  8. All of these are true:
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  9. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The front yard abuts an arterial
  10. Within one-half mile of a major transit stop (RCW 36.70A.681)
  11. None of these is true:
    • Within one-half mile of a major transit stop (RCW 36.70A.681)
  12. The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
  13. None of these is true:
    • The dwelling is built on a residential infill lot created through an Infill Lot Subdivision