Sign in

MS · Medical Services

Olympia, WA · OMC 18.06 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family Residences
Home✓1 ADU✓1
————
Manufactured Homes
Home✓1 ADU✓1
————
Townhouses
Home✓1 ADU✓1
————
Transitional Housing
Home✓1 ADU✓1
Home✓1 ADU✓1
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Permanent Supportive Housing
Home✓1 ADU✓1
Home✓1 ADU✓1
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Emergency Housing
HomeA2 ADU✓2
————
Duplexes—
Home✓1 ADU✓1
———
Co-Housing—
HomeA1 ADU✓1
HomeA1 ADU✓1
HomeA1 ADU✓1
—
Apartments above ground floor in mixed use development——
Home✓3 ADU✓3
Home✓3 ADU✓3
—
Apartments———
Home✓4 ADU✓4
—
Courtyard Apartments———
Home✓1 ADU✓1
—
Group Homes————
Home✓1 A5 H6 ADU✓1 ✓5 ✓6
Boarding Homes————
Home✓1 ADU✓1
Single Room Occupancy Units————
Home✓1 ADU✓1
Lodging Houses————
Home✓ ADU✓
Collegiate Greek system residences————
Home✓1 ADU✓1
Dormitories————
Home✓1 ADU✓1
Nursing/Convalescent Homes————
Home✓ ADU✓
Congregate Care Facilities————
Home✓ ADU✓
Retirement Homes————
Home✓1 ADU✓1
Indoor Emergency Shelters————
HomeH ADU✓
Indoor Emergency Housing————
HomeH ADU✓
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set OMC 18.06.080 Table 6.02 (MS column)
12 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units)1
Minimum unitsNot set OMC 18.06.080 Table 6.02 (MS column)
4 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units)1
Minimum lot size7,200 sq ft OMC 18.06.080 Table 6.02 (MS column)
Not set OMC 18.04.060(DD)(3)(a)
for Emergency Housing (1 unit)2
the largest of 7,200, 7,200 + (500 × (the largest of residents − 9, 0)) sq ft OMC 18.06.080 Table 6.02 (MS column); 18.04.060(K)(3)
for Group Homes (group living)5; Group Homes (group living)6
Maximum residentsNot set OMC 18.04.060(K)(2)
  • 8 persons7 OMC 18.06.040 Table 6.01
  • 6 persons8 OMC 18.06.040 Table 6.01
for Group Homes (group living)1
40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living)

3. Building standards

StandardValueExceptions
Front setbackNot set OMC 18.06.080 Table 6.02 (MS column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum front setback10 ft OMC 18.06.080 Table 6.02 (MS column)
Side setback
  • 15 + (5 × (the largest of building stories − 3, 0)) ft9 OMC 18.06.080 Table 6.02 (MS column)
  • 10 ft10 OMC 18.06.080 Table 6.02 (MS column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Rear setback
  • 15 + (5 × (the largest of building stories − 3, 0)) ft9 OMC 18.06.080 Table 6.02 (MS column)
  • 15 ft10 OMC 18.06.080 Table 6.02 (MS column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.06.080 Table 6.02 (MS column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum height75 ft OMC 18.06.080 Table 6.02 (MS column)
Maximum lot coverage50% OMC 18.06.080 Table 6.02 (MS column)
60% OMC 18.06.080 Table 6.02 (MS column); 18.64.080(C)
for Townhouses (1 unit)1
Maximum impervious surface60% OMC 18.06.080 Table 6.02 (MS column)
Minimum parking
  • 0 spaces per unit11 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.5 spaces per unit12 OMC 18.38.100 Table 38.01
Not set OMC 18.38.100 Table 38.01
for Emergency Housing (1 unit)2; Indoor Emergency Shelters (group living); Indoor Emergency Housing (group living)
  • 0 spaces per unit11 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • employees on the largest shift + (residents ÷ 5) spaces12 OMC 18.38.100 Table 38.01
for Group Homes (group living)1; Group Homes (group living)5; Group Homes (group living)6
  • 0 spaces per sleeping unit11 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.25 spaces per sleeping unit12 OMC 18.38.100(C)(5)
for Boarding Homes (group living)1; Single Room Occupancy Units (group living)1; Lodging Houses (group living)
  • 0 spaces per unit11 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 3) + 1 spaces12 OMC 18.38.100 Table 38.01
for Collegiate Greek system residences (group living)1; Dormitories (group living)1
  • 0 spaces per unit11 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces12 OMC 18.38.100 Table 38.01
for Nursing/Convalescent Homes (group living); Congregate Care Facilities (group living); Retirement Homes (group living)1
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units OMC 18.04.060(A)(1); 18.04.060(A)(6)

Building

StandardValueExceptions
Side setback
  • 15 + (5 × (the largest of building stories − 3, 0)) ft9 OMC 18.06.080 Table 6.02 (MS column)
  • 10 ft10 OMC 18.06.080 Table 6.02 (MS column)
Rear setback
  • 15 + (5 × (the largest of building stories − 3, 0)) ft9 OMC 18.06.080 Table 6.02 (MS column)
  • 15 ft10 OMC 18.06.080 Table 6.02 (MS column)
Maximum height75 ft OMC 18.06.080 Table 6.02 (MS column)
Minimum parking0 spaces per unit OMC 18.38.100 Table 38.01
Maximum unit size1,000 sq ft OMC 18.04.060(A)(3)
Attached to the main houseNot required OMC 18.04.060(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
7,200 sq ft OMC 18.06.080 Table 6.02 (MS column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
7,200 sq ft OMC 18.06.080 Table 6.02 (MS column)
Unit Lot Subdivisions OMC 17.33.010(B)(1) — — — —
Binding Site Plans OMC 17.34.010; 17.34.070(A) A — —
Minimum lot size
No limit OMC 17.34.020
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Site is within 600 feet of Lilly Road
  2. A dwelling on the lot is being reconstructed after damage from earthquake, fire, storm or other natural disaster
  3. The apartments are above the ground floor of a mixed use development
  4. All of these are true:
    • Main dwelling units on the lot is more than 4
    None of these is true:
    • Site is within 600 feet of Lilly Road
  5. All of these are true:
    • Any of these is true:
      • Residents is more than 8
      • All of these are true:
        • Residents is more than 6
        • None of these is true:
          • DSHS approves the group home for up to 8 clients
    • Residents is at most 20
    None of these is true:
    • Site is within 600 feet of Lilly Road
  6. All of these are true:
    • Residents is more than 20
    None of these is true:
    • Site is within 600 feet of Lilly Road
  7. DSHS approves the group home for up to 8 clients
  8. None of these is true:
    • DSHS approves the group home for up to 8 clients
  9. The yard is next to a residential zone
  10. None of these is true:
    • The yard is next to a residential zone
  11. Any of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  12. None of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)