Sign in

GC · General Commercial

Olympia, WA · OMC 18.06 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family Residences
Home✓ ADU✓
————
Manufactured Homes
Home✓ ADU✓
————
Townhouses
Home✓ ADU✓
————
Transitional Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent Supportive Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Emergency Housing
HomeA1 ADU✓1
————
Duplexes—
Home✓ ADU✓
———
Co-Housing—
HomeA ADU✓
HomeA ADU✓
HomeA ADU✓
—
Apartments———
Home✓2 ADU✓2
—
Courtyard Apartments———
Home✓ ADU✓
—
Group Homes————
Home✓ ADU✓
Boarding Homes————
Home✓ ADU✓
Single Room Occupancy Units————
Home✓ ADU✓
Lodging Houses————
Home✓ ADU✓
Collegiate Greek system residences————
Home✓ ADU✓
Dormitories————
Home✓ ADU✓
Nursing/Convalescent Homes————
HomeH ADU✓
Congregate Care Facilities————
HomeH ADU✓
Retirement Homes————
Home✓ ADU✓
Indoor Emergency Shelters————
Home✓ ADU✓
Indoor Emergency Housing————
Home✓ ADU✓
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set OMC 18.06.080 Table 6.02 (GC column)
12 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units)
Minimum unitsNot set OMC 18.06.080 Table 6.02 (GC column)
4 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units)
Minimum lot sizeNo limit OMC 18.06.080 Table 6.02 (GC column)
1,600 sq ft OMC 18.06.080 Table 6.02 (GC column)
for Townhouses (1 unit)
Not set OMC 18.04.060(DD)(3)(a)
for Emergency Housing (1 unit)1
7,200 + (500 × (the largest of residents − 9, 0)) sq ft OMC 18.06.060(K)(1); 18.04.060(K)(3)
for Group Homes (group living)3; Group Homes (group living)4
Maximum residentsNot set OMC 18.04.060(K)(2)
  • 8 persons5 OMC 18.06.040 Table 6.01
  • 6 persons6 OMC 18.06.040 Table 6.01
for Group Homes (group living)
40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living)

3. Building standards

StandardValueExceptions
Front setback5 ft OMC 18.06.080 Table 6.02 (GC column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Side setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft7 OMC 18.06.080 Table 6.02 (GC column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft8 OMC 18.06.080 Table 6.02 (GC column)
  • 5 ft9 OMC 18.06.080 Table 6.02 (GC column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Rear setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft10 OMC 18.06.080 Table 6.02 (GC column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft11 OMC 18.06.080 Table 6.02 (GC column)
  • 10 ft12 OMC 18.06.080 Table 6.02 (GC column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.06.080 Table 6.02 (GC column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum height
  • 35 ft13 OMC 18.06.080 Table 6.02 (GC column)
  • 75 ft14 OMC 18.06.080 Table 6.02 (GC column)
Maximum lot coverage
  • 85%15 OMC 18.06.080 Table 6.02 (GC column)
  • 70%16 OMC 18.06.080 Table 6.02 (GC column)
Maximum impervious surface85% OMC 18.06.080 Table 6.02 (GC column)
Minimum parking
  • 0 spaces per unit17 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.5 spaces per unit18 OMC 18.38.100 Table 38.01
Not set OMC 18.38.100 Table 38.01
for Emergency Housing (1 unit)1; Indoor Emergency Shelters (group living); Indoor Emergency Housing (group living)
  • 0 spaces per unit17 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • employees on the largest shift + (residents ÷ 5) spaces18 OMC 18.38.100 Table 38.01
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4
  • 0 spaces per sleeping unit17 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.25 spaces per sleeping unit18 OMC 18.38.100(C)(5)
for Boarding Homes (group living); Single Room Occupancy Units (group living); Lodging Houses (group living)
  • 0 spaces per unit17 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 3) + 1 spaces18 OMC 18.38.100 Table 38.01
for Collegiate Greek system residences (group living); Dormitories (group living)
  • 0 spaces per unit17 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces18 OMC 18.38.100 Table 38.01
for Nursing/Convalescent Homes (group living); Congregate Care Facilities (group living); Retirement Homes (group living)
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units OMC 18.04.060(A)(1); 18.04.060(A)(6)

Building

StandardValueExceptions
Front setback5 ft OMC 18.06.080 Table 6.02 (GC column)
Side setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft7 OMC 18.06.080 Table 6.02 (GC column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft8 OMC 18.06.080 Table 6.02 (GC column)
  • 5 ft9 OMC 18.06.080 Table 6.02 (GC column)
Rear setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft10 OMC 18.06.080 Table 6.02 (GC column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft11 OMC 18.06.080 Table 6.02 (GC column)
  • 10 ft12 OMC 18.06.080 Table 6.02 (GC column)
Maximum height
  • 35 ft13 OMC 18.06.080 Table 6.02 (GC column)
  • 75 ft14 OMC 18.06.080 Table 6.02 (GC column)
Minimum parking0 spaces per unit OMC 18.38.100 Table 38.01
Maximum unit size1,000 sq ft OMC 18.04.060(A)(3)
Attached to the main houseNot required OMC 18.04.060(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (GC column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (GC column)
Unit Lot Subdivisions OMC 17.33.010(B)(1) — — — —
Binding Site Plans OMC 17.34.010; 17.34.070(A) A — —
Minimum lot size
No limit OMC 17.34.020
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. A dwelling on the lot is being reconstructed after damage from earthquake, fire, storm or other natural disaster
  2. Main dwelling units on the lot is more than 4
  3. All of these are true:
    • Any of these is true:
      • Residents is more than 8
      • All of these are true:
        • Residents is more than 6
        • None of these is true:
          • DSHS approves the group home for up to 8 clients
    • Residents is at most 20
  4. Residents is more than 20
  5. DSHS approves the group home for up to 8 clients
  6. None of these is true:
    • DSHS approves the group home for up to 8 clients
  7. The yard is next to an R 4, R 4-8 or R 6-12 district
  8. All of these are true:
    • The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
    None of these is true:
    • The yard is next to an R 4, R 4-8 or R 6-12 district
  9. None of these is true:
    • The yard is next to an R 4, R 4-8 or R 6-12 district
    • The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
  10. The yard is next to a single-family use or an R 4, R 4-8 or R 6-12 district
  11. All of these are true:
    • The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
    None of these is true:
    • The yard is next to a single-family use or an R 4, R 4-8 or R 6-12 district
  12. None of these is true:
    • The yard is next to a single-family use or an R 4, R 4-8 or R 6-12 district
    • The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
  13. Any portion of the building is within 100 feet of an R 4, R 4-8 or R 6-12 district
  14. None of these is true:
    • Any portion of the building is within 100 feet of an R 4, R 4-8 or R 6-12 district
  15. At least 50% of the required parking is under the building
  16. None of these is true:
    • At least 50% of the required parking is under the building
  17. Any of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  18. None of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)