CS-H · Commercial Services - High Density

Olympia, WA · OMC 18.06 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family Residences
Home✓ ADU✓
————
Manufactured Homes
Home✓ ADU✓
————
Townhouses
Home✓ ADU✓
————
Transitional Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent Supportive Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Emergency Housing
HomeA1 ADU✓1
————
Duplexes—
Home✓ ADU✓
———
Apartments———
Home✓2 ADU✓2
—
Group Homes————
Home✓ ADU✓
Boarding Homes————
Home✓ ADU✓
Single Room Occupancy Units————
Home✓ ADU✓
Lodging Houses————
Home✓ ADU✓
Collegiate Greek system residences————
Home✓ ADU✓
Dormitories————
Home✓ ADU✓
Nursing/Convalescent Homes————
HomeH ADU✓
Congregate Care Facilities————
HomeH ADU✓
Retirement Homes————
Home✓ ADU✓
Indoor Emergency Shelters————
Home✓ ADU✓
Indoor Emergency Housing————
Home✓ ADU✓
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set OMC 18.04.080 Table 4.04 (RMH column); OMC 18.06.080 Table 6.02 (CS-H column)
1,600 sq ft OMC 18.04.080 Table 4.04 (RMH column); OMC 18.06.080 Table 6.02 (CS-H column)
for Townhouses (1 unit)
7,200 + (500 × (the largest of residents − 9, 0)) sq ft OMC 18.06.060(K)(1); 18.04.060(K)(3)
for Group Homes (group living)3; Group Homes (group living)4
Maximum residentsNot set OMC 18.04.060(K)(2)
  • 8 persons5 OMC 18.06.040 Table 6.01
  • 6 persons6 OMC 18.06.040 Table 6.01
for Group Homes (group living)
40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft7 OMC 18.04.080 Table 4.04 (RMH column)
  • 5 ft8 OMC 18.04.080 Table 4.04 (RMH column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Side setback5 ft OMC 18.04.080 Table 4.04 (RMH column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Street side setback10 ft OMC 18.04.080 Table 4.04 (RMH column)
Rear setback
  • 20 ft7 OMC 18.04.080 Table 4.04 (RMH column)
  • 5 ft8 OMC 18.04.080 Table 4.04 (RMH column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.06.080 Table 6.02 (CS-H column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum height60 ft OMC 18.04.080 Table 4.04 (RMH column); OMC 18.06.080 Table 6.02 (CS-H column)
Maximum lot coverageNo limit OMC 18.06.080 Table 6.02 (CS-H column)
Maximum impervious surface85% OMC 18.04.080 Table 4.04 (RMH column)
Minimum parking
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.5 spaces per unit10 OMC 18.38.100 Table 38.01
Not set OMC 18.38.100 Table 38.01
for Emergency Housing (1 unit)1; Indoor Emergency Shelters (group living); Indoor Emergency Housing (group living)
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • employees on the largest shift + (residents ÷ 5) spaces10 OMC 18.38.100 Table 38.01
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4
  • 0 spaces per sleeping unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.25 spaces per sleeping unit10 OMC 18.38.100(C)(5)
for Boarding Homes (group living); Single Room Occupancy Units (group living); Lodging Houses (group living)
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 3) + 1 spaces10 OMC 18.38.100 Table 38.01
for Collegiate Greek system residences (group living); Dormitories (group living)
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces10 OMC 18.38.100 Table 38.01
for Nursing/Convalescent Homes (group living); Congregate Care Facilities (group living); Retirement Homes (group living)
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)
Minimum open space
  • 10%11 OMC 18.04.080 Table 4.04 (RMH column)
  • Not set12 OMC 18.04.080 Table 4.04 (RMH column)
Not set OMC 18.06.080 Table 6.02 (CS-H column)
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4; Boarding Homes (group living); Single Room Occupancy Units (group living); Lodging Houses (group living); Collegiate Greek system residences (group living); Dormitories (group living); Nursing/Convalescent Homes (group living); Congregate Care Facilities (group living); Retirement Homes (group living); Indoor Emergency Shelters (group living); Indoor Emergency Housing (group living); Emergency Housing Facility (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units OMC 18.04.060(A)(1); 18.04.060(A)(6)

Building

StandardValueExceptions
Front setback
  • 10 ft7 OMC 18.04.080 Table 4.04 (RMH column)
  • 5 ft8 OMC 18.04.080 Table 4.04 (RMH column)
Side setback5 ft OMC 18.04.080 Table 4.04 (RMH column)
Rear setback
  • 20 ft7 OMC 18.04.080 Table 4.04 (RMH column)
  • 5 ft8 OMC 18.04.080 Table 4.04 (RMH column)
Maximum height
  • 24 ft13 OMC 18.04.080 Table 4.04 (RMH column)
  • 60 ft14 OMC 18.04.080 Table 4.04 (RMH column); OMC 18.06.080 Table 6.02 (CS-H column)
Minimum parking0 spaces per unit OMC 18.38.100 Table 38.01
Maximum unit size1,000 sq ft OMC 18.04.060(A)(3)
Attached to the main houseNot required OMC 18.04.060(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
  • 12,500 sq ft15 OMC 18.06.080 Table 6.02 (CS-H column)
  • 7,200 sq ft16 OMC 18.06.080 Table 6.02 (CS-H column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
  • 12,500 sq ft15 OMC 18.06.080 Table 6.02 (CS-H column)
  • 7,200 sq ft16 OMC 18.06.080 Table 6.02 (CS-H column)
Unit Lot Subdivisions OMC 17.33.010(B)(1) — — — —
Binding Site Plans OMC 17.34.010; 17.34.070(A) A — —
Minimum lot size
No limit OMC 17.34.020
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. A dwelling on the lot is being reconstructed after damage from earthquake, fire, storm or other natural disaster
  2. Main dwelling units on the lot is more than 4
  3. All of these are true:
    • Any of these is true:
      • Residents is more than 8
      • All of these are true:
        • Residents is more than 6
        • None of these is true:
          • DSHS approves the group home for up to 8 clients
    • Residents is at most 20
  4. Residents is more than 20
  5. DSHS approves the group home for up to 8 clients
  6. None of these is true:
    • DSHS approves the group home for up to 8 clients
  7. Building height is at least 35
  8. Building height is less than 35
  9. Any of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  10. None of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  11. All of these are true:
    • Main dwelling units on the lot is at least 7
    • The project is subject to land use review
  12. Not all of these are true:
    • Main dwelling units on the lot is at least 7
    • The project is subject to land use review
  13. The ADU is detached from the principal unit
  14. None of these is true:
    • The ADU is detached from the principal unit
  15. Building height is more than 35
  16. Building height is at most 35