Sign in

AS · Auto Services

Olympia, WA · OMC 18.06 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Emergency Housing
HomeA1 ADU—
————
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set OMC 18.04.060(DD)(3)(a)
No limit OMC 18.06.080 Table 6.02 (AS column)
for Emergency Housing Facility (group living)
Maximum residents40 persons OMC 18.50.060(A)(1)(f)

3. Building standards

StandardValueExceptions
Front setback30 ft OMC 18.06.080 Table 6.02 (AS column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Side setback5 ft OMC 18.06.080 Table 6.02 (AS column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Street side setback30 ft OMC 18.06.080 Table 6.02 (AS column)
Rear setback15 ft OMC 18.06.080 Table 6.02 (AS column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.06.080 Table 6.02 (AS column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum height40 ft OMC 18.06.080 Table 6.02 (AS column)
Maximum lot coverage85% OMC 18.06.080 Table 6.02 (AS column)
Maximum impervious surface85% OMC 18.06.080 Table 6.02 (AS column)
Minimum parkingNot set OMC 18.38.100 Table 38.01
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (AS column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (AS column)
Unit Lot Subdivisions OMC 17.33.010(B)(1) — — — —
Binding Site Plans OMC 17.34.010; 17.34.070(A) A — —
Minimum lot size
No limit OMC 17.34.020
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. A dwelling on the lot is being reconstructed after damage from earthquake, fire, storm or other natural disaster