Sign in

CR · Medium-Density Residential (cottage residential)

North Bend, WA · NBMC 18.10; 18.11 · Official code

By right: 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Family Detached Dwellings
Home✓1 ADU✓1
————
Designated Manufactured Homes
Home✓1 ADU✓1
————
Two-unit home—
Home✓2 ADU—
———
Cottages———
Home✓ ADU—
—
Adult Family Homes————
Home✓ ADU✓
Homes for the Elderly and Related————
Home✓ ADU✓
Boarding Houses————
Home✓ ADU✓
Transitional Housing————
Home✓ ADU—
Permanent Supportive Housing————
Home✓ ADU—
Interim Housing Facilities————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units24 units NBMC 18.11.040(D)(1)(a)
Minimum units4 units NBMC 18.11.040(E)(2)(a)
Minimum lot sizeNot set NBMC 18.10.040
8,000 sq ft NBMC 18.11.060(A)(1)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1
0 sq ft NBMC 18.11.040(F)
for Two-unit home (2 units)2; Cottages (4+ units)
Minimum lot widthNot set NBMC 18.10.040
60 ft NBMC 18.11.060(A)(5); NBMC 18.10.040(3)(a)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1
50 ft NBMC 18.10.040(3)(e)
for Interim Housing Facilities (group living)
Maximum densityNot set NBMC 18.10.040
4 units per acre NBMC 18.11.060(A)(2); NBMC 18.11.040(A)(2)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1
10 units per acre NBMC 18.11.040(A)(1)
for Two-unit home (2 units)2; Cottages (4+ units)
Minimum development sizeNot set NBMC 18.10.040
  • 174,240 sq ft3 NBMC 18.11.060(A)
  • Not set4 NBMC 18.11.040(E)(3)(a)(iii)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1
Maximum residentsNot set NBMC 18.10.040
6 persons NBMC 18.10.050(1.31)(b)
for Adult Family Homes (group living)
100 persons NBMC 18.22.050(B)
for Interim Housing Facilities (group living)
Maximum sleeping unitsNot set NBMC 18.10.040
2 sleeping units NBMC 18.10.050(1.42)(b)
for Boarding Houses (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 30 ft5 NBMC 18.11.060(A)(8)
  • 20 ft6 NBMC 18.11.060(A)(5); NBMC 18.10.040(4)(a)
20 ft NBMC 18.11.040(H)(1)
for Two-unit home (2 units)2; Cottages (4+ units); Interim Housing Facilities (group living)
Not set NBMC 18.10.040; NBMC 18.11
for Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living)
Maximum front setbackNot set NBMC 18.10.040
30 ft NBMC 18.11.060(A)(5); NBMC 18.10.040(5)(a)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1; Transitional Housing (group living); Permanent Supportive Housing (group living)
Side setback5 ft NBMC 18.11.060(A)(5); NBMC 18.10.040(6)(a)
  • 25 ft7 NBMC 18.11.040(H)(3)
  • 10 ft8 NBMC 18.11.040(H)(2)
for Two-unit home (2 units)2; Cottages (4+ units)
Not set NBMC 18.10.040; NBMC 18.11
for Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living)
10 ft NBMC 18.10.040(6)(g)
for Interim Housing Facilities (group living)
Total side setbacksNot set NBMC 18.10.040
15 ft NBMC 18.11.060(A)(5); NBMC 18.10.040(6)(a)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1; Transitional Housing (group living); Permanent Supportive Housing (group living)
Street side setbackNot set NBMC 18.10.040
10 ft NBMC 18.10.040 footnote (9)
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1; Transitional Housing (group living); Permanent Supportive Housing (group living)
Rear setback25 ft NBMC 18.11.060(A)(5); NBMC 18.10.040(7)(a)
  • 25 ft7 NBMC 18.11.040(H)(3)
  • 10 ft8 NBMC 18.11.040(H)(2)
for Two-unit home (2 units)2; Cottages (4+ units)
Not set NBMC 18.10.040; NBMC 18.11
for Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living)
20 ft NBMC 18.10.040(7)(e)
for Interim Housing Facilities (group living)
Building separationNot set NBMC 18.10.040
10 ft NBMC 18.11.040(I)
for Two-unit home (2 units)2; Cottages (4+ units)
Maximum height35 ft NBMC 18.11.060(A)(3)
  • 25 ft9 NBMC 18.11.040(K)
  • 18 ft10 NBMC 18.11.040(K)
for Two-unit home (2 units)2; Cottages (4+ units)
Not set NBMC 18.10.040; NBMC 18.11
for Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living)
Maximum lot coverage50% NBMC 18.11.060(A)(4)
Not set NBMC 18.10.040; NBMC 18.11
for Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living); Interim Housing Facilities (group living)
Maximum impervious surface65% NBMC 18.11.060(A)(5); NBMC 18.10.040(10)(a)
50% NBMC 18.11.040(J)
for Two-unit home (2 units)2; Cottages (4+ units)
Not set NBMC 18.10.040; NBMC 18.11
for Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living)
75% NBMC 18.10.040(10)(e)
for Interim Housing Facilities (group living)
Maximum floor area ratioNot set NBMC 18.10.040(13); NBMC 18.34
0.35 NBMC 18.11.040(A)(3)
for Two-unit home (2 units)2; Cottages (4+ units)
Minimum parkingNot set NBMC 18.16.090
2 spaces per unit NBMC 18.16.090
for Single-Family Detached Dwellings (1 unit)1; Designated Manufactured Homes (1 unit)1
  • 1 space per unit11 NBMC 18.11.040(G)(1)
  • 1.5 spaces per unit12 NBMC 18.11.040(G)(2)
  • 2 spaces per unit13 NBMC 18.11.040(G)(3)
for Two-unit home (2 units)2; Cottages (4+ units)
Space to accommodate 1 parking space per employee for the peak employee load, plus 1 space per dwelling unit for units allowing to have on-site storage of vehicles, and 1 space per 10 dwelling units for visitors is required NBMC 18.16.090
for Adult Family Homes (group living); Homes for the Elderly and Related (group living)
1 space per unit NBMC 18.16.090
for Boarding Houses (group living)
Maximum unit sizeNot set NBMC 18.10.040
Two-unit homes may have an average unit size of 1,000 square feet; however, the total structure shall not exceed 2,000 square feet in size. NBMC 18.11.040(B)(3)
for Two-unit home (2 units)2
1,500 sq ft NBMC 18.11.030(A); NBMC 18.11.040(B)(1)
for Cottages (4+ units)
Maximum building floor areaNot set NBMC 18.10.040
2,000 sq ft NBMC 18.11.030(C); 18.11.040(B)(3)
for Two-unit home (2 units)2
Maximum units per buildingNot set NBMC 18.10.040
2 units NBMC 18.11.030(C)
for Two-unit home (2 units)2

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units NBMC 18.10.050(1.52)(a); NBMC 18.10.041(I)
Minimum lot size0 sq ft NBMC 18.10.050(1.52)(f)(iv)

Building

StandardValueExceptions
Front setback20 ft NBMC 18.10.050(1.52)(f)(i)-(ii); NBMC 18.11.060(A)(5); NBMC 18.10.040(4)(a)
Side setback
  • 5 ft14 NBMC 18.10.050(1.52)(f)(i); NBMC 18.11.060(A)(5); NBMC 18.10.040(6)(a)
  • 5 ft15 NBMC 18.10.050(1.52)(f)(ii); NBMC 18.11.060(A)(5); NBMC 18.10.040(6)(a)
Rear setback
  • 25 ft14 NBMC 18.10.050(1.52)(f)(i); NBMC 18.11.060(A)(5); NBMC 18.10.040(7)(a)
  • 25 ft15 NBMC 18.10.050(1.52)(f)(ii); NBMC 18.11.060(A)(5); NBMC 18.10.040(7)(a)
Maximum height
  • 35 ft14 NBMC 18.10.050(1.52)(f)(i); NBMC 18.11.060(A)(3)
  • 25 ft15 NBMC 18.10.050(1.52)(f)(iii); NBMC 18.11.060(A)(3)
Minimum parking1 space per unit NBMC 18.16.090; NBMC 18.10.050(1.52)(g)
Maximum unit size1,000 sq ft NBMC 18.10.050(1.52)(c)
Attached to the main houseNot required NBMC 18.10.050(1.52)(b)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NBMC 17.12.015; 17.12.060(A) A up to 9 NBMC 17.04.330; 17.12.010 —
Minimum lot size
0 sq ft NBMC 18.11.040(F)
Subdivision NBMC 17.12.015; 17.12.030(A) H 10 or more NBMC 17.04.340 —
Minimum lot size
0 sq ft NBMC 18.11.040(F)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • The standard single-family homes are located to separate the cottage clusters
    • All of these are true:
      • The homes are a standard single-family neighborhood containing up to 20 units
      • A cottage development of not less than 24 units is proposed or already exists
  2. The unit is part of a cottage housing development under Chapter 18.11 NBMC
  3. The standard single-family homes are located to separate the cottage clusters
  4. None of these is true:
    • The standard single-family homes are located to separate the cottage clusters
  5. Lot is along Stilson Avenue
  6. None of these is true:
    • Lot is along Stilson Avenue
  7. The setback is from an exterior line abutting property zoned LDR
  8. None of these is true:
    • The setback is from an exterior line abutting property zoned LDR
  9. The home has a roof slope of 6:12 or greater for all parts of the roof higher than 18 feet
  10. None of these is true:
    • The home has a roof slope of 6:12 or greater for all parts of the roof higher than 18 feet
  11. Floor area of one unit is less than 700
  12. All of these are true:
    • Floor area of one unit is at least 700
    • Floor area of one unit is at most 1,000
  13. Floor area of one unit is more than 1,000
  14. None of these is true:
    • The ADU is detached from the principal dwelling
  15. The ADU is detached from the principal dwelling